The Acoustic Output Estimation for Therapeutic Ultrasound Equipment using Electro-Acoustic Radiation Conductance (전기-음향 방사컨덕턴스를 이용한 치료용 초음파 자극기의 음향출력 예측)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.264-269
    • /
    • 2011
  • To increase therapeutic efficiency and biological safety, it is important to precision control of acoustic output for therapeutic ultrasound equipment. In this paper, the electro-acoustic radiation conductance, one of electroacoustic characteristics of therapeutic ultrasound equipment, was measured by the radiation force balance method according to IEC 61161 standards and the acoustic output was estimated using the electro-acoustic radiation conductance. The estimation of acoustic output was conducted to continuous wave mode and pulse wave mode of duty cycle between 20% and 80%. The differences between prediction values and measurement results are within 5% of measurement uncertainty, which is a reasonably good agreement. The results show that acoustic output controlled by electro-acoustic radiation conductance was found to be an effective method.

The Study of the Photo Diode Output Signal for Pusle Radiation Detection (펄스방사선 탐지를 위한 Photo Diode 출력특성 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.869-871
    • /
    • 2012
  • In this paper, we make silicon photodiodes for the detection of pulsed radiation that affects electronics devices and study the output characteristics of photodiodes using circuit design. We conducted the simulation for pulse sensing circuit and experimented the photodiode output characteristics using a high luminance light emitting diode. The results can be used for the design of the input sensor that is trigger of additional module for protecting a electoronics circuit from high energy pulse radiation.

  • PDF

Optimal Current Detect MPPT Control of PV System for Robust with Environment Changing (환경변화에 강인한 태양광 발전의 최적전류 MPPT 제어)

  • Choi, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.47-58
    • /
    • 2011
  • This paper proposes the optimal current detect(OCD) maximum power point tracking(MPPT) control of photovoltaic(PV) system for robust with environment changing. The output characteristics of the solar cell is a nonlinear and affected by a temperature, the solar radiation and temperature. Conventional MPPT control methods are tracked the maximum power point by constant incremental value. So these methods are slow the response speed and generated the vibration in steady state and cannot track the MPP in environment condition changing. And power loss is generated because of the self-excitation vibration in MPP region. To solve this problem, this paper proposes the novel control algorithm. Proposed algorithm is detected the optimal current in two control region using the output power and current curve. Detected current is used the converter switching for tracking the MPP. Proposed algorithm is compared output power error to conventional algorithm with radiation and temperature changing. In addition, the validity of the algorithm is proved through the output error response characteristics.

Study on the Dose Characteristics of the PTW-LinaCheck Dosimeter and Its Application to Daily Output Measurement (PTW-LinaCheck 측정기의 선량 특성과 일일 출력측정 응용에 관한 연구)

  • Jeong, Dong-Hyeok;Lee, Kang-Kyoo;Moon, Un-Chul;Kim, Hyun-Jin;Kim, Young-Seok;Moon, Sun-Rock
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.56-62
    • /
    • 2008
  • In this study, we have investigated the dose characteristics of PTW-LinaCheck designed to detect output of medical LINAC and discussed clinical use of the detector. The reproducibility, linearity, and dose rate dependency of the dosimeter were measured for photons of 6 and 15MV and the electrons of 4, 6, 9, 12, and 16MeV. To know the error ranges of the measured data in daily output measurement, the response variations due to geometrical setup errors were measured. As a result of measurement, the error range from the geometrical setup and the reproducibility was less than ${\pm}0.6%$ for given beam qualities in daily output measurement, where the errors from the linearity and the dose rate dependency were negligible. Finally, we concluded that the LinaCheck dosimeter has a good characteristics in terms of dose and setup convenience in daily output measurement. In addition we have shown an examples of clinical use of this dosimeter for measuring daily output more than 60 days.

  • PDF

An Improved Photovoltaic System Output Prediction Model under Limited Weather Information

  • Park, Sung-Won;Son, Sung-Yong;Kim, Changseob;LEE, Kwang Y.;Hwang, Hye-Mi
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1874-1885
    • /
    • 2018
  • The customer side operation is getting more complex in a smart grid environment because of the adoption of renewable resources. In performing energy management planning or scheduling, it is essential to forecast non-controllable resources accurately and robustly. The PV system is one of the common renewable energy resources in customer side. Its output depends on weather and physical characteristics of the PV system. Thus, weather information is essential to predict the amount of PV system output. However, weather forecast usually does not include enough solar irradiation information. In this study, a PV system power output prediction model (PPM) under limited weather information is proposed. In the proposed model, meteorological radiation model (MRM) is used to improve cloud cover radiation model (CRM) to consider the seasonal effect of the target region. The results of the proposed model are compared to the result of the conventional CRM prediction method on the PV generation obtained from a field test site. With the PPM, root mean square error (RMSE), and mean absolute error (MAE) are improved by 23.43% and 33.76%, respectively, compared to CRM for all days; while in clear days, they are improved by 53.36% and 62.90%, respectively.

Influence of the Thin-Film Ag Electrode Deposition Thickness on the Current Characteristics of a CVD Diamond Radiation Detector

  • Ban, Chae-Min;Lee, Chul-Yong;Jun, Byung-Hyuk
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.131-136
    • /
    • 2018
  • Background: We investigated the current characteristics of a thin-film Ag electrode on a chemical vapor deposition (CVD) diamond. The CVD diamond is widely recognized as a radiation detection material because of its high tolerance against high radiation, stable response to various dose rates, and good sensitivity. Additionally, thin-film Ag has been widely used as an electrode with high electrical conductivity. Materials and Methods: Considering these properties, the thin-film Ag electrode was deposited onto CVD diamonds with varied deposition thicknesses (${\fallingdotseq}50/98/152/257nm$); subsequently, the surface thickness, surface roughness, leakage current, and photo-current were characterized. Results and Discussion: The leakage current was found to be very low, and the photo-current output signal was observed as stable for a deposited film thickness of 98 nm; at this thickness, a uniform and constant surface roughness of the deposited thin-film Ag electrode were obtained. Conclusion: We found that a CVD diamond radiation detector with a thin-film Ag electrode deposition thickness close to 100 nm exhibited minimal leakage current and yielded a highly stable output signal.

A Novel MPPT Control of PV MIC System Considering the Shaded Effect (그림자 영향을 고려한 PV MIC 시스템의 새로운 MPPT 제어)

  • Choi, Jung-Sik;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.21-33
    • /
    • 2012
  • This paper presents the new maximum power point tracking(MPPT) control of the photovoltaic(PV) module integrated converter(MIC) system considering the shadow influence. The output characteristics of the solar cell is a nonlinear and affected by a temperature, the solar radiation and influence of a shadow. Particularly, MIC system is very sensitive to the shadow influence because the capacity is very small. In order to increase an output and efficiency of the solar power generation, the maximum power point(MPP) obeying control are necessary. Conventional perturbation and observation(PO) and Incremental conductance(IC) are the method finding MPP by the continued self-excitation vibration. The MPPT control is unable to be performed by rapid output change affected by the shadow. To solve this problem, the new control algorithm of the multi-level in which the step value changes by output change is presented. In case there are the solar radiation, a temperature and shadow influence, the presented algorithm treats and compares the conventional control algorithm and output error. In addition, the validity of the algorithm is proved. through the output error response characteristics.

An Experimental Study on Sound Radiation Characteristics of Radial Tire for a Passenger Car Due to Excitation (가진에 의한 승용차 타이어의 음향방사특성에 관한 실험적 연구)

  • 김병삼;이태근;홍동표
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.10
    • /
    • pp.2426-2436
    • /
    • 1993
  • Vibration characteristics of a tire play an important role to judge a ride conformability and sound quality for a passenger car. In this study, the experimental investigation for the sound radiation of a radial tire has been examined. Based on the sound intensity techniques, the sound pressure field and the sound radiation are measured. It turns out that air pressure in tire, tread patterns, and aspect ratio of the tire govern the sound radiation characteristics. Then a numerical analysis for the tire element is conducted. During analysis, the tire element is modelled as an elastic ring. The comparison shows that the numerical output correlates to the experimental data.

Feasibility Study of Data Acquisition System based on Oscilloscope for Radiation Detector (방사선 검출기용 데이터획득장치로서의 오실로스코프 활용 가능성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1804-1809
    • /
    • 2017
  • A data acquisition (DAQ) system based on oscilloscope was developed and evaluated for radiation detector. The dedicated LabVIEW program that perform the oscilloscope control and the data process was developed. Triggered events for each analog channel were acquired and the output signals were subsequently digitized and recorded for offline processing. Radiation pulse generation circuit was developed to evaluate the intrinsic characteristics of DAQ system. Energy linearity and energy resolution performances were assessed by voltage-peak channels and FWHM obtained from Gaussian fit, respectively. Radiation detector consists of LYSO and GAPD array. The 16 output signals were multiplexed by the RCD networks, and they were fed into the custom-made preamplifiers. Voltage-peak channels was linearly changed as a function of input voltage and the estimated coefficient of determination ($R^2$) was 0.999. No considerable changes in voltage resolution were observed. All 16 crystals were clearly identifiable on the resulting flood image and the mean energy resolution was ~15.1%. This study demonstrated that it is feasible to develop the DAQ system based on oscilloscope and LabVIEW program for radiation detector and the proposed approach offers opportunities to build simple DAQ system in various radiation measurement field.

Radiation testing of low cost, commercial off the shelf microcontroller board

  • Fried, Tomas;Di Buono, Antonio;Cheneler, David;Cockbain, Neil;Dodds, Jonathan M.;Green, Peter R.;Lennox, Barry;Taylor, C. James;Monk, Stephen D.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3335-3343
    • /
    • 2021
  • The impact of gamma radiation on a commercial off the shelf microcontroller board has been investigated. Three different tests have been performed to ascertain the radiation tolerance of the device from a nuclear decommissioning deployment perspective. The first test analyses the effect of radiation on the output voltage of the on-board voltage regulator during irradiation. The second test evaluated the effect of gamma radiation on the voltage characteristics of analogue and digital inputs and outputs. The final test analyses the functionality of the microcontroller when using an external, shielded voltage regulator instead of the on-board voltage regulator. The results suggest that a series of latch-ups occurs in the microcontroller during irradiation, causing increased current drain which can damage the voltage regulator if it does not have short-circuit protection. The analogue to digital conversion functionality appears to be more sensitive to gamma radiation than digital and analogue output functionality. Using an external, shielded voltage regulator can prove beneficial when used for certain applications. The collected data suggests that detaching the voltage regulator can extend the lifespan of the platform up to approximately 350 Gy.