• Title/Summary/Keyword: Radiation correlation

Search Result 831, Processing Time 0.023 seconds

A Study of Bleaching Phenomenon of Otter (Lutra lutra) Spraints in Relation to Weather Conditions and Characteristics of Sprainting Sites (기상조건과 배설지 특성에 따른 수달(Lutra lutra) 분변의 표백현상에 관한 연구)

  • Noh, Eun-Young;Han, Sung-Yong;Yoo, Jeong-Chil
    • Journal of Wetlands Research
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • The bleaching phenomenon of otter spraints is indicates that the age of spraints (fresh or old spraints). As previous studies on the old otter faeces (spraint) have focused only on the external changes of spraints, it has been difficult to explain the difference of the decomposition rates among old spraints. We hypothesized that the micrometeorology difference caused by various characteristics of sprainting sites such as porosity and consistency of soil could affect the extent of the decomposition rate, the solar bleaching phenomenon of spraints used as a measure of the patterns of old spraints. Sprainting sites were classified into four types (Clay, Sand, Rock and Concrete spot) and each type was divided into two groups according to the sunlight condition (Sunny site and Shady site) to measure the effect of solar radiation. Micrometeorology of the sites were evaluated by measuring temperatures and humidities of the sites during the whole season. The variations in micrometeorology of the sunny sites according to the sprainting site types were examined with correlation analyses between the factors of micrometeorology. The analyses on the bleaching phenomenon of the spraints by micrometeorology showed that the highest rate of bleaching was found at the 'Rock spot' and 'Concrete spot' of the sunny site and especially in summer, the highest rate of bleaching ($63.4{\pm}7.6%$) was found at the 'Clay spot' of the sunny sites. The lowest rate of bleaching was found at the 'Sand spot' of the sunny sites. The above findings show that the difference in bleaching rates among sprainting sites was due to the seasonal or sunny condition. In addition, we found that the differences in thermal conductivity among sprainting site characteristics have resulted in different sprainting site temperature which have affected the rate of bleaching of spraints. In conclusion, this study suggests that studies of otters on their population size and home ranges using spraints as an indirect sign, should consider the effects of sprainting site characteristics and weather conditions.

Analysis on Estimating Evapotranspiration of Paddy Rice (벼의 증발산량(蒸發散量) 산정(算定)에 관(關)한 실험(實驗) 분석(分析))

  • Suh, Seung Duk;Lee, Jong Kook
    • Current Research on Agriculture and Life Sciences
    • /
    • v.3
    • /
    • pp.28-35
    • /
    • 1985
  • This work Was carried out to obtain the most suitable crop coefficient for the paddy rice growing in Taegu area. The result was due to the comparative measurements of evapotranspiration formula in terms of Blaney & Criddle and eight other formulas with those produced by experiment particularly in this area. The crop coefficient, evapotranspiration and transpiration ratio produced by this research are hopefully expected to be of service in the future calculation of evapotranspiration without repeating experiment respectively, whenever the water requirement of paddy rice is planned in Taegu and its vicinity. The accomplished results could be summarized as follows : The maximum amount of evapotranspiration was recorded in the early and middle parts of August. The average reading of evapotranspiration was 6.33mm/day throughout the growth. The evapotranspiration had a highly significant correlation with pan evaporation, solar radiation, sunshine hours and relative humidity of meteorological elements. K and Kc by the use of Blaney & Criddle formula calculated at 0.76 to 1.45 and 0.82 to 1.27, respectively. Its peak value appeared commonly in early August. The ratio of transpiration was 269.03.

  • PDF

Evaluation of Dosimetric Characteristics of Reproducibility, Linearity and Dose Dependence of Optically Stimulated Luminescence Dosimeters in Co-60 Gamma-rays (Co-60 감마선을 이용한 광자극발광선량계의 재현성, 선형성, 선량의존성에 대한 특성평가)

  • Han, Su Chul;Choi, Sang Hyoun;Park, Seungwoo;Kim, Chul Hang;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Chan Hyeong;Ji, Young Hoon;Yi, Chul Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • We aimed to evaluate the dosimetric characteristics of reproducibility, linearity and dose dependence of optical stimulated luminance dosimeter (OSLD) in the Co-60 Gamma-rays and to analyze with a precedent study in field of the diagnostic radiography and radiotherapy. The reproducibility was 0.76% of the coefficient of variation, the homogeneity was within 1.5% of the coefficient of variation and OSLD had supra-linear response more than 3 Gy. So the correlation between dose and count was fitted by quadratic function. The count depletion by repeated reading was 0.04% per reading regardless of the irradiated dose. And the half time of decay curve according to the irradiated dose was 0.68 min. with 1 Gy, 1.04 min. with 5 Gy, and 1.10 min. with 10 Gy, respectively. In case of annealing for 30 min, the removal rate was 88% with 1 Gy, 90% with 5 Gy, and 92% with 10 Gy, respectively and 99% in case of annealing time for 4 hour. It is feasible to use OSLDs for dose evaluation in Co-60 Gamma-rays when considering the uncertainty on the procedure according to the irradiated dose.

Image-Based Assessment and Clinical Significance of Absorbed Radiation Dose to Tumor in Repeated High-Dose $^{131}I$ Anti-CD20 Monoclonal Antibody (Rituximab) Radioimmunotherapy for Non-Hodgkin's Lymphoma (반복적인 $^{131}I$ rituximab 방사면역치료를 시행 받은 비호지킨 림프종 환자 군에서 종양 부위의 영상기반 방사선 흡수선량 평가와 임상적 의의)

  • Byun, Byung-Hyun;Kim, Kyeong-Min;Woo, Sang-Keun;Choi, Tae-Hyun;Kang, Hye-Jin;Oh, Dong-Hyun;Kim, Byeong-Il;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.60-71
    • /
    • 2009
  • Purpose: We assessed the absorbed dose to the tumor ($Dose_{tumor}$) by using pretreatment FDG-PET and whole-body (WB) planar images in repeated radioimmunotherapy (RIT) with $^{131}I$ rituximab for NHL. Materials and Methods: Patients with NHL (n=4) were administered a therapeutic dose of $^{131}I$ rituximab. Serial WB planar images alter RIT were acquired and overlaid to the coronal maximum intensity projection (MIP) PET image before RIT. On registered MIP PET and WB planar images, 2D-ROls were drawn on the region of tumor (n=7) and left medial thigh as background, and $Dose_{tumor}$ was calculated. The correlation between $Dose_{tumor}$ and the CT-based tumor volume change alter RIT was analyzed. The differences of $Dose_{tumor}$ and the tumor volume change according to the number of RIT were also assessed. Results: The values of absorbed dose were $397.7{\pm}646.2cGy$ ($53.0{\sim}2853.0cGy$). The values of CT-based tumor volume were $11.3{\pm}9.1\;cc$ ($2.9{\sim}34.2cc$), and the % changes of tumor volume before and alter RIT were $-29.8{\pm}44.3%$ ($-100.0%{\sim}+42.5%$), respectively. $Dose_{tumor}$ and the tumor volume change did not show the linear relationship (p>0.05). $Dose_{tumor}$ and the tumor volume change did not correlate with the number of repeated administration (p>0.05). Conclusion: We could determine the position and contour of viable tumor by MIP PET image. And, registration of PET and gamma camera images was possible to estimate the quantitative values of absorbed dose to tumor.

Simultaneous estimation of fatty acids contents from soybean seeds using fourier transform infrared spectroscopy and gas chromatography by multivariate analysis (적외선 분광스펙트럼 및 기체크로마토그라피 분석 데이터의 다변량 통계분석을 이용한 대두 종자 지방산 함량예측)

  • Ahn, Myung Suk;Ji, Eun Yee;Song, Seung Yeob;Ahn, Joon Woo;Jeong, Won Joong;Min, Sung Ran;Kim, Suk Weon
    • Journal of Plant Biotechnology
    • /
    • v.42 no.1
    • /
    • pp.60-70
    • /
    • 2015
  • The aim of this study was to investigate whether fourier transform infrared (FT-IR) spectroscopy can be applied to simultaneous determination of fatty acids contents in different soybean cultivars. Total 153 lines of soybean (Glycine max Merrill) were examined by FT-IR spectroscopy. Quantification of fatty acids from the soybean lines was confirmed by quantitative gas chromatography (GC) analysis. The quantitative spectral variation among different soybean lines was observed in the amide bond region ($1,700{\sim}1,500cm^{-1}$), phosphodiester groups ($1,500{\sim}1,300cm^{-1}$) and sugar region ($1,200{\sim}1,000cm^{-1}$) of FT-IR spectra. The quantitative prediction modeling of 5 individual fatty acids contents (palmitic acid, stearic acid, oleic acid, linoleic acid, linolenic acid) from soybean lines were established using partial least square regression algorithm from FT-IR spectra. In cross validation, there were high correlations ($R^2{\geq}0.97$) between predicted content of 5 individual fatty acids by PLS regression modeling from FT-IR spectra and measured content by GC. In external validation, palmitic acid ($R^2=0.8002$), oleic acid ($R^2=0.8909$) and linoleic acid ($R^2=0.815$) were predicted with good accuracy, while prediction for stearic acid ($R^2=0.4598$), linolenic acid ($R^2=0.6868$) had relatively lower accuracy. These results clearly show that FT-IR spectra combined with multivariate analysis can be used to accurately predict fatty acids contents in soybean lines. Therefore, we suggest that the PLS prediction system for fatty acid contents using FT-IR analysis could be applied as a rapid and high throughput screening tool for the breeding for modified Fatty acid composition in soybean and contribute to accelerating the conventional breeding.

A Study of Injection Dose for Patients and Exposure Dose for Technologists from the PET/CT Systems (PET/CT 장비 특성에 따른 방사성 의약품 주입량이 방사선 종사자에게 미치는 영향)

  • Park, Hoon-Hee;Oh, Ki-Beak;Lee, Seung-Jae;Bhan, Young-Kag;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Purpose: It appears the different value when the injection dose is calculating for patients on each PET/CT systems. It directly affects the technologists' radiation exposed dose. We studied the effect of the variable injection doses from several PET/CT systems to exposure dose for technologists. Materials and Methods: Six technologists have worked for 5 months through unit rotations with 3 PET/CT systems {Scanner 1 (S1): 0.15 mCi/kg, Scanner 2 (S2): 0.17 mCi/kg, Scanner 3 (S3): 0.12 mCi/kg}. Eighteen to 19 patients have had examinations per a day on each PET/CT systems. Examination parameters were adjusted to the same. TLDs were used for checking the exposure dose of technologists. Results: Each technologists' the monthly average exposure dose was as follows; S1: 0.76 mSv, S2: 0.93 mSv, S3: 0.47 mSv. The maximum exposure dose was 1.12 mSv, and minimum was 0.42 mSv. The results showed significance in the correlation between the PET/CT system and the exposure dose (p<0.005). Conclusion: When the amount of injection dose was small, the exposure dose was decreased not only the patients but also the technologists. The exposure dose was decreased by the individual proficiency of technologists. However, the low injection dose can highly reduce the exposure dose for technologist so that there will be needed to following studies.

  • PDF

Self-Efficacy, Self-Care Behavior, Posttraumatic Growth, and Quality of Life in Patients with Cancer according to Disease Characteristics (질병관련 특성에 따른 암환자의 자기효능감, 자가간호행위, 외상 후 성장, 삶의 질)

  • Choi, Jinho;Lee, Sunyoung;An, Byungduck
    • Journal of Hospice and Palliative Care
    • /
    • v.19 no.2
    • /
    • pp.170-179
    • /
    • 2016
  • Purpose: This study examined self-efficacy, self-care behavior, posttraumatic growth, and quality of life in cancer patients and their levels by disease characteristics groups to identify patient groups that require psychosocial intervention. Methods: We surveyed 107 patients using a structured questionnaire about the four factors and analyzed the factors by stratifying the patients by the period after the cancer diagnosis, by stage and by current treatment status. Results: The mean score for self-efficacy was 37.78, and that for self-care behavior 49.96. Patients who were diagnosed less than one year ago scored higher on medication, a sub-category of self-care behavior, than the post-diagnosis period of 1~2 year group. The score was higher in the currently-treated group than the follow-up and distant metastasis groups. For posttraumatic growth, the mean was 56.17, and the factor was higher in the 1~2 year post-diagnosis group after than the less than one year group. The score was higher in the follow-up group than the currently-treated group. With regard to quality of life, the mean score was 25.79, and no significant correlation was found with disease characteristics. Conclusion: A shorter post-diagnosis period increased self-care behavior, and the greatest posttraumatic growth was reported by the 1~2 year post-diagnosis group. It may be necessary to provide cancer patients with an education program and other strategies less than one year after the diagnosis to improve self-efficacy and self-care behavior. To promote post-traumatic growth, it may be helpful to provide patients with psychosocial intervention within two years after the diagnosis.

The Relationship between Behavior of Radiographic Safety Control and Job Stress in Dental Hygienist (치과위생사의 방사선안전관리 행위와 직무스트레스와의 관계)

  • Jang, Jong-Hwa;Hwang, Su-Lyun;Jung, Hong-ryang
    • Journal of dental hygiene science
    • /
    • v.10 no.4
    • /
    • pp.265-271
    • /
    • 2010
  • This study was to investigate the level of knowledge, recognition, behavior of radiographic safety control and job stress in dental hygienists and to determine the relationship among variables. The subjects were 256(56.9%), who were worked in dental hospital and clinic with mean age of $29.59{\pm}7.30$. Data was collected using a self administrated questionnaire from April 4 to May 15, 2010. Behavior of radiographic safety control was measured using the 15-items and job stress was measured using the 5-items with 5-point likert scale. The data were analyzed with t-test, one-way ANOVA and pearson correlation coefficient using the SPSS WIN 17.0 program. Regarding job stress, the subjects was a mean of 2.63 out of a maximum 5 points. The level of knowledge, recognition, behavior of radiographic safety control a mean of 3.11, 4.08 and 3.43 out of a maximum 5 points. Recognition and behavior of radiographic safety control was negative related job stress in this study. Based on the findings, behavior of radiographic safety control is associated with job stress. These results suggest that various program should be considered for radiation safety control of dental hygienists.

A study on the soil $CO_2$ Efflux in Quercus acutissima stand at Mt. Bulam urban nature park (불암산 도시자연공원 상수리나무군락의 토양호흡 특성 연구)

  • Kim, Jeong-Seob;Kong, Seok-Jun;Yang, Keum-Chul
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.6
    • /
    • pp.762-768
    • /
    • 2014
  • The purpose of this study is to analyze the soil $CO_2$ efflux and micro-climate of a preserved forest area located in a Mt. bulam urban nature park Quercus acutissima stand from June 2013 to May 2014. The research showed that the soil and heterotrophic $CO_2$ efflux were $28.14{\pm}7.99$ to $582.47{\pm}318.51$ and $12.32{\pm}8.04$ to $415.71{\pm}159.92mg\;CO_2{\cdot}m^{-2}{\cdot}h^{-1}$, respectively. In addition the seasonal soil $CO_2$ efflux of summer, autumn, winter, spring were 1169.1, 454.81, 72.08 and $494.23g\;CO_2{\cdot}m^{-2}{\cdot}month^{-1}$, respectively. On the other hand, the seasonal heterotrophic $CO_2$ efflux were 526.20, 340.09, 45.13 and $374.9g\;CO_2{\cdot}m^{-2}{\cdot}month^{-1}$, respectively. Moreover, the annual soil and heterotrophic $CO_2$ efflux was found to be 2190.22 and $1286.33g\;CO_2{\cdot}m^{-2}{\cdot}yr^{-1}$, respectively. The exponential function was also utilized for the regression analysis in order to correlate the environmental factors with the soil and heterotrophic $CO_2$ efflux. It was found out that both air and soil temperatures were positively correlated with the soil and heterotrophic $CO_2$ efflux. However, the amount of solar radiation and soil moisture has showed low correlation for both types of $CO_2$ efflux. Contribution of root $CO_2$ efflux to total soil $CO_2$ efflux in this Quercus acutissima stand was 33.60%.

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.