• 제목/요약/키워드: Radiation Pipe

검색결과 76건 처리시간 0.029초

천연가스 계량배관 내$\cdot$외의 온도차가 계량오차에 미치는 영향에 관한 연구 (A Study on Effects of Temperature Difference between the Inside and Outside the Meter-Run on Natural Gas Flow Measurement Errors)

  • 하영철;이철구;장승룡;이강진
    • 한국가스학회지
    • /
    • 제2권1호
    • /
    • pp.83-89
    • /
    • 1998
  • 단열이 되어 있지 않은 천연가스 계략배관에서 배관 내$\cdot$외의 온도차로 인한 오리피스 유량계 오차를 정성적으로 실험하였다. 고려된 주요 인자는 유속과 대기온도이며 태양복사열도 일부 고려되었다. 실험결과 유량이 극히 작고, 배관 내$\cdot$외의 온도차가 큰 하절기 유동조건에서도 그다지 큰 오차는 발생하지 않는 것으로 분석되었다.

  • PDF

급기가 되는 이중바닥 구조체의 열 성능 평가 (Estimation of the thermal performance on the double slab floor with supplying air)

  • 차광석;박명식;이대우;남우동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

수소 Tube Trailer 저장시설에서의 수소가스 누출에 따른 사고피해예측에 관한 연구 (A Study of Damage Assessment Caused by Hydrogen Gas Leak in Tube Trailer Storage Facilities)

  • 김종락;황성민;윤명오
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.32-38
    • /
    • 2011
  • 산업현장에서 폭발성가스의 사용이 꾸준이 증가 함에 따라 작업자는 물론 일반지역주민들에까지 사고로 인한 생명에 위험을 처하기도 한다. 수소사용공정에서의 사고피해는 공정자체에 국한 되는 것이 아니라 대형화재나 폭발로 이어져 다수의 사상자를 유발시키므로 사고의 유형과 원인을 규명하고 피해규모를 예측하여 이에 대한 안전대책을 수립, 운영하는 것이 필요하다. 본 연구에서는 MLCC(Multi Layer Ceramic Capacitor) 소성공정의 수소저장 사용시설에서 화재 폭발시 위험범위를 예측하였다. 실제 사고데이터의 분석결과 사고발생빈도가 가장 많은 배관누출에 대하여 사고 피해예측 시나리오 모델로 선정, 적용하였다. 10 mm Hole에서 120 Bar의 압력으로 수소가스 누출시 Jet fire가 발생되며 Radiation Level 4($kw/m^2$)의 경우 최대 12.45 m까지 복사열의 영향을 주었다. 또한 사고피해 예측을 통한 안전성확보와 개선방안을 제시하였다.

전립선암의 세기조절 방사선치료 시 불균질부에 의한 선량변화에 관한 고찰 (The Investigation Regarding the Dose Change due to the Heterogeneity of Prostate Cancer Treatment with IMRT)

  • 윤일규;박장필;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제19권2호
    • /
    • pp.107-112
    • /
    • 2007
  • 목 적: 본원에서 시행하고 있는 전립선암의 세기조절 방사선치료시 직장 내에 존재하는 불균질부에 의한 선량변화를 전산화 치료계획 선량과 자체 제작한 전립선암 환자형 골반 팬톰을 이용하여 측정한 선량을 비교하고자 한다. 대상 및 방법: 전립선암 환자형 골반 팬톰(타원형의 물 팬톰: $30\times20\times20cm^3$, 방광, 직장, 정낭을 묘사하는 팬톰)을 제작하였으며, 전산화단층촬영으로 3차원 영상을 획득하였다. 전산화치료계획장치(ECLIPSE, Varian, USA), 6 MV X선(Clinac 6EX, Varian, USA)을 이용하여 세기조절 방사선치료계획을 수립한 후, 전립선암 환자형 골반 팬톰을 이용하여 직장벽, 방광벽, 정낭 부위에 TLD를 삽입하고, 전산화치료계획 선량과 비교하였다. 결 과: 전산화치료계획에 의한 선량은 직장벽 100%, 방광벽 52%, 우측 정낭 86%, 좌측 정낭 87%, 표면 18%였으나, TLD로 측정 한 선량은 직장벽 89%, 방광벽 54%, 우측 정낭 85%, 좌측 정낭 84%, 표면 17%로 측정되었다. 직장벽은 11%, 방광벽은 2%, 우측 정낭은 1%, 좌측 정낭 3%, 표면 1%의 선량차이를 확인하였다. 결 론: 본원에서 개발한 전립선암 환자형 골반 팬톰으로 전산화치료계획에서 구현하는 불균질부 선량계산의 오차를 확인할 수 있었으며, 다양한 선량 측정 장치(TLD, film)를 이용하여 쉽고 간편하게 선량 검증을 할 수 있을 것으로 사료된다.

  • PDF

태양열 집열관 과열방지를 위한 지중열교환기 연구 (A study of geothermal heat dump for solar collectors overheat protection)

  • 황현창;;이계복;이석호
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.616-622
    • /
    • 2016
  • 하절기 줄어드는 온수부하는 태양열 집열기 과열의 주된 원인이다. 과열방지목적으로 공냉 또는 차단막이 사용되는데 이는 추가적인 기계적요소를 필요하게 되고 장기 운용 시 파손 등의 우려에 따라 그 신뢰도도 크게 저하된다. 지중열교환기는 지열을 열원으로 방열 또는 흡열을 진행하는데, 지열을 고 열원으로 하여 흡열을 목적으로 하는 연구가 대다수이며 지열원이 저열원으로 이용하는 방열에 대한 연구는 부족한 편이다. 그리하여 본 연구에서는 태양열집열판의 과열방지를 목적으로 하는 지중열교환기의 가능성 및 그 성능에 대한 연구를 진행하였다. 여름철 최대 $150^{\circ}C$이상의 고온을 유지하는 태양열집열판의 열을 방출하기 위하여 1.2m의 하부 깊이를 갖는 50m 나선형 지중열교환기를 설치하였고 이를 통해 순간 냉각이 가능한 것으로 확인되었으며, 태양열집열판의 여름철 과열에 의한 파손을 방지할 수 있었다. 그리고 다양한 변수에 대한 이론적인 계산을 통하여 0.33kg/s의 최저 순환유량만 유지해주면 지열 열교환기의 길이에 따른 방열효과에 큰 영향을 미치지 않음을 판단할 수 있다. 또한 축열조와의 공동 사용시 냉각효과는 여름철 과열시 충분한 과열방지 제어가 가능한 것으로 조사되었다.

저온 상변화 물질 특성을 이용한 태양열 물펌프 실용화 연구개발(II) ­시스템 구성 및 작동분석 (Development of a Solar Powered Water Pump by Using Low Temperature Phase Change Material ­ System Construction and Operation Analysis ­)

  • 김영복;이양근;이승규;김성태;나우정;민영봉
    • 한국축산시설환경학회지
    • /
    • 제9권2호
    • /
    • pp.69-78
    • /
    • 2003
  • 태양열을 동력원으로 하여 열에너지를 동력으로 변환, 물을 양수할 목적으로 저온 상변화물질인 펜탄을 작동물질로 하는 에너지변환장치를 제작하여 실험하였다. 장치는 각부의 크기를 그 기능과 상호작용 원리에 따라 논리에 맞게 최적 설계하였다. 장치의 제작 후 실험을 통하여 그 운전 특성을 분석하여 성능향상에 필요한 자료를 획득하고자 하였다. 작동물질인 펜탄을 가열하는 탱크 내부의 온도는 사이클 경과시간에 따라 약 $40­86^{\circ}C$ 범위에서 변동하고 있었으며, 물탱크내 온도 약 $23­24^{\circ}C$, 공기탱크 내 온도 $22­23.5^{\circ}C$ 범위에서 비교적 일정하게 유지되고 있었다. 응축기내의 온도와 냉각수출구 온도는 냉각수입구 온도수준에 따라 정의 상관관계로 변하고 있는 것을 알 수 있었으며, 또한 열 교환 능력도 냉각수 온도수준이 낮을수록 커진다는 것을 확인하였다. 물탱크 내 온도와 응축기내 온도가 상당히 차이가 나므로 물탱크와 응축기와의 연결거리를 최소화하고 연결파이프 크기를 큰 것으로 하여 내부물질이동 저항을 줄이는 것이 바람직하다는 것을 알 수 있었다. 실험 중 양수량은 1.6­2.4 liter로 나타났으며, 냉각시간의 수준에 따른 물탱크내의 흡입물높이 상승은 차이를 나타내지 않았다. 응축기로부터의 냉각수 배출파이프가 연장되지 않은 경우 냉각수 유량이 5.9 liter/min 이었으나 연장파이프가 있을 때는 2.3 liter/min으로 나타났다. 이러한 현상에서 양수하는 물의 온도가 낮고 유량이 부족한 경우에는 연장파이프를 이용하는 것이 좋고, 냉각수치 양은 풍부하지만 그 온도가 낮지 않은 경우에는 연장파이프를 이용하지 않는 것이 좋다는 사실을 알 수 있다. 실험에서의 응축기내 냉각수의 최대 열교환량은 95.75 kJ/min로 나타났다. 작동물질가열탱크와 기액 분리탱크 내의 압력은 0.13­0.14 MPa.a, 물탱크와 응축기내의 압력은 약 0.11 MPa.a정도로 나타났다.

  • PDF

Camera Self-Calibration from Two Ellipse Contours in Pipes

  • Jeong, Kyung-Min;Seo, Yong-Chil;Choi, Young-Soo;Cho, Jai-Wan;Lee, Sung-Uk;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1516-1519
    • /
    • 2004
  • A tele-operated robot should be used to maintain and inspect nuclear power plants to reduce the radiation exposure to the human operators. During an overhaul of the nuclear power plants in Korea, a ROV(Remotely Operated Vehicle) may enter a cold-leg connected to the reactor to examine the state of the thermal sleeve and it's position in the safety injection nozzle. To measure the positions of the thermal sleeve or scratches from the video images captured during the examination, the camera parameters should be identified. However, the focal length of the CCD camera could be increased to a close up of the target and the aspect ratio and the center of the image could also be varied with capturing devices. So, it is desired to self-calibrated the intrinsic parameters of the camera and capturing device with the video images captured during the examination. In the video image of the safety injection nozzle, two or more circular grooves around the nozzle are shown as ellipse contours. In this paper, we propose a camera self-calibration method using a single image containing two circular grooves which are the greatest circles of the cylindrical nozzle whose radius and distance are known.

  • PDF

HPT 방식의 온열침대 디자인 개발에 관한 연구 (A Study on Thermo-Bed Design Development of HPT System)

  • 이봉규
    • 한국가구학회지
    • /
    • 제22권1호
    • /
    • pp.72-81
    • /
    • 2011
  • These days, beds have been developed not as furniture to sleep in but Healthcare Furniture. The function of heating, non-electronic-waves and far-infrared rays have been added. Also, eco-friendly materials such as stone, mud, rubber and wood are combined to them together with the radiation-heating method using heat conduction through electronic coil and hot water circulation. Modern people suffer from stress and fatigue. The hot issue is "health." Focused on the health, the development of design for beds considering the influence electronic waves, anions, deep sleep and the density of toxic materials have on human bodies has become urgent. In this study, the trend, specification and efficiency of the functional health-related electronic coil technology are analyzed. Through the analysis, the environmental standards are set. According to them, technology, eco-friendly materials and additional functions for the development of the design are considered. Also, the government is promoting the IEC international standardization for the Korean traditional floor heating style beds. In preparation for that, we adopted new HPT method technology. It enables non-electronic-waves, low electricity and stable temperature maintenance control for the warm top and the cool bottom. Also, the head boards and the frames of the beds can be separated. Through this separation, the beds can be easily moved or installed. Eco-friendly materials such as Hinoki cypress wood and red clay and the existing tables function are combined to the head boards so they can be used as drawers and display shelves. If they are used as separate items, they can be used as covers. This is how we suggest the design for the heating beds.

  • PDF

파사드 일체형 자연순환 태양열온수기 유동해석 (Flow Analysis of Facade Integrated Solar Water Heater with Natural Circulation)

  • 백남춘;이왕제;임희원;신우철
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.167-172
    • /
    • 2016
  • Purpose: The solar water heater with natural circulation has been used for several decades in the world as it is automatically operated without a pump and controller and is easy to maintain and repair. After the subsidy was offered from 2012, the solar water heater with natural circulation is becoming increasingly popular in Korea. Recently, the development of a wall-integrated solar water heater, which improves the applicability of buildings and prevents the overheating in the summer, is being developed. On the other hand, the design and performance evaluation data of solar water heaters are very inadequate, and analysis of heat and flow is required to develop a new type of solar water heater. Method: Therefore, in this study, we proposed a new simplified system analysis model that reflects heat and pressure loss from the test results of KS B ISO 9806-1 (Solar collector test method), assuming that the collector is a simple pipe system, the validity of which was verified through experiments. Result: As a result, first, the RMSE of the system circulation flow rate and the average temperature of the inlet and outlet of the collector according to the experimental results and the simulation are 0.05563 and 0.88530, respectively, which are very consistent. Secondly, the mass flow rate is increased linearly with the increase of the solar radiation, and the mass flow rate is 0.0104 ~ 0.0180kg/s in the range of $200{\sim}380W/m^2$ of solar irradiance. Compared with the test flow rate 0.0764kg / s of the test collector, it showed a level of less than 20%.

단일진공관 태양열집열기의 형상변화 및 접촉저항에 따른 집열효율 연구 (Study on Thermal Efficiency according to Configuration Change and Contact Resistance of Solar Collector with Single Evacuated Tube-type)

  • 최보원;양영준
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.189-195
    • /
    • 2014
  • 신재생에너지 분야 중 특히 태양에너지를 이용하는 분야는 자원의 무한 및 청정성 때문에 그 사용량이 증가 추세에 있다. 우리나라에서 태양열에너지의 이용률이 전체 에너지 사용량 중 아직 미미한 실정이지만, 근래 정부의 정책적 지원에 힘입어 이 분야에 대한 연구가 활발히 이루어지고 있다. 본 연구는 태양열집열기의 형상 변화에 따른 집열효율을 조사하기 위하여 단일진공관 태양열집열기를 이용한 실험 및 이중진공관 태양열집열기와의 비교 실험을 수행하였다. 그 결과, 본 실험장치에서 히트 파이프의 최고온도의 차이로부터 태양열집열기 형상 변화에 따른 집열효율의 변화를 확인할 수 있었다. 또한 본 연구대상 태양열집열기의 히트파이프의 온도가 비교대상 태양열집열기보다 높음에도 불구하고 방열핀의 온도가 낮게 관측되었다. 이것은 본 연구대상의 태양열집열기는 히트파이프 방열부인 헤드부와 방열핀 사이의 접촉저항이 비교대상의 접촉저항보다 크다는 것을 나타내며, 집열효율을 높이기 위해서는 태양열집열기의 여러 부분의 성능개선뿐만 아니라 접촉저항에 의한 집열손실도 감소시켜야 함을 확인할 수 있었다.