A Study on Effects of Temperature Difference between the Inside and Outside the Meter-Run on Natural Gas Flow Measurement Errors

천연가스 계량배관 내$\cdot$외의 온도차가 계량오차에 미치는 영향에 관한 연구

  • Ha Youngcheol (Fluid Flow Research Team, R&D Training Center, KOGAS) ;
  • Lee Chulgu (Fluid Flow Research Team, R&D Training Center, KOGAS) ;
  • Chang Seungyong (Fluid Flow Research Team, R&D Training Center, KOGAS) ;
  • Lee Kangjin (Fluid Flow Research Team, R&D Training Center, KOGAS)
  • 하영철 (한국가스공사 연구개발원 유체유동연구팀) ;
  • 이철구 (한국가스공사 연구개발원 유체유동연구팀) ;
  • 장승룡 (한국가스공사 연구개발원 유체유동연구팀) ;
  • 이강진 (한국가스공사 연구개발원 유체유동연구팀)
  • Published : 1998.03.01

Abstract

Experiments had been conducted Qualitatively regarding flow measurement errors of orifice flowmeter due to temperature difference between the inside and outside the natural gas meter-run in case of no pipe insulations. The primary factors considered in this study are fluid velocity and surrounding temperature. In addition, a portion of thermal radiation due to the sun was involved as a factor. The results showed that the considerable errors were not detected even in conditions of low flow rates and large temperature difference between the inside and outside the meter-run.

단열이 되어 있지 않은 천연가스 계략배관에서 배관 내$\cdot$외의 온도차로 인한 오리피스 유량계 오차를 정성적으로 실험하였다. 고려된 주요 인자는 유속과 대기온도이며 태양복사열도 일부 고려되었다. 실험결과 유량이 극히 작고, 배관 내$\cdot$외의 온도차가 큰 하절기 유동조건에서도 그다지 큰 오차는 발생하지 않는 것으로 분석되었다.