• Title/Summary/Keyword: Radiation Dosimeter

Search Result 408, Processing Time 0.03 seconds

Development of Radiation Dosimeter using Commercial p-MOSFET (상용 p-MOSFET을 이용한 방사선 선량계 개발)

  • Lee, Nam-Ho;Choi, Young-Su;Lee, Yong-B.;Youk, Geun-Uck
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • When a metal oxide field effect transistor (MOSFET) is exposed to ionizing radiation, electron/hole pairs are generated in its oxide layer. The slow moving holes of them are trapped in the oxide layer of p-MOSFET and appear as extra charges that change the characteristics of the transistor. The radiation-induced charges directly impact the threshold (turn-on) voltage of the transistor. This paper describes the use of the radiation-induced threshold voltage change as an accumulated radiation dose monitoring sensor. Two kinds of commercial p-type MOSFETS were tested in a Co-60 gamma irradiation facility to see their capabilities as a radiation dosimeter. We found that the transistors showed good linearity in their threshold voltage shift characteristics with radiation dose. The results demonstrate the potential use of commercial p-MOSFETS as inexpensive radiation sensors for the first time.

  • PDF

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.

A Study on the Skin Dose Measurement of Glass Dosimeter Use During Rectal Cancer 3field Technic and Cervical Cancer 4field Technic Radiation Therapy (직장암 3문조사와 자궁경부암 4문조사 방사선 치료 시 유리선량계를 이용한 피부선량 측정에 관한 연구)

  • Shin, Seong-Soo;Choi, Won-Sik;Park, Cheol-Soo;Lee, Sun-Yeb;Cho, Jae-Hwan;Seo, Jeong-Min;Shim, Jae-Koo;Kim, Chan-Hyeong;Goo, Eun-Hoe;Kim, Eng-Chan
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.157-163
    • /
    • 2011
  • Recently a variety of high technologies for radiation therapy (IMRT, SRS,. 3D-RT, etc.) has been developed. For the cervical and rectal cancer, 3field or 4field radiotherapy have been applied to the patients. In the case of two-dimensional treatment, one of the most typical side-effects is skin burn due to the radiation irradiation. In general the skin dose is evaluated by only a single measurement during the whole treatment period. In this study, however, skin dose was measured in each radiation treatment and the total skin dose was accumulated in a glass dosimeter through all the cases. After simulating the skin dose from treatment planning system, the results were compared with the actual skin doses. The results showed a good agreement between two data sets. Even though there are certain amount of errors caused by the patient movement along the treatment, the difference between actual dose and simulated dose was within the accepted range of error.

Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity

  • Kim, Jae Seok;Park, Byeong Ryong;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Jang, Won Il;Cho, Gyu Seok;Kim, Hyun;Chang, Insu;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.479-485
    • /
    • 2022
  • At the Korea Institute of Radiological and Medical Sciences, physical human phantoms were developed to evaluate various radiation protection quantities, based on the mesh-type reference computational phantoms of the International Commission on Radiological Protection. The physical human phantoms were fabricated such that a radiophotoluminescent glass dosimeter (RPLGD) with a Tin filter, namely GD-352M, could be inserted into them. A Tin filter is used to eliminate the overestimated signals in low-energy photons below 100 keV. The measurement uncertainty of the RPLGD reader system based on GD-352M should be analyzed for obtaining reliable protection quantities before using it for practical applications. Generally, the measurement uncertainty of RPLGD systems without Tin filters is analyzed for quality assurance of radiotherapy units using a high-energy photon beam. However, in this study, the measurement uncertainty of GD-352M was analyzed for evaluating the protection quantities. The measurement uncertainty factors in the RPLGD include the reference irradiation, regression curve, reproducibility, uniformity, energy dependence, and angular dependence, as described by the International Organization for Standardization (ISO). These factors were calculated using the Guide to the Expression of Uncertainty in Measurement method, applying ISO/ASTM standards 51261(2013), 51707(2015), and SS-ISO 22127(2019). The measurement uncertainties of the RPLGD reader system with a coverage factor of k = 2 were calculated to be 9.26% from 0.005 to 1 Gy and 8.16% from 1 to 10 Gy. A blind test was conducted to validate the RPLGD reader system, which demonstrated that the readout doses included blind doses of 0.1, 1, 2, and 5 Gy. Overall, the En values were considered satisfactory.

Comparison on the Dosimetry of TLD and OSLD Used in Nuclear Medicine (광자극발광선량계와 열형광선량계를 이용한 핵의학과 선량 측정비교)

  • Lee, Wang-Hui;Kim, Sung-Chul;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.329-334
    • /
    • 2012
  • For the dosimetry of the radiation workers, film badge, Thermo Luminescent Dosimeter (TLD), and glass dosimeter are being used and recently, there is a growing trend of using Optically Stimulated Luminescence Dosimeter (OSLD) in the world. However, OSLD is only being applied some of the field in Korea and there has been almost no study made related to OSLD. Thus, the accumulated radiation dose of TLD and OSLD that have been most frequently used in the field was compared in the radiation workers of nuclear medicine and their working areasfor 3 months. As a result, the average surface dose showed 0.85 mSv difference with 1.27 mSv for TLD and 2.12 mSv for OSLD while having 0.73 mSv difference for the average depth dose with 1.33 mSv for TLD and 2.06 mSv for OSLD. The surface dose and depth dose of OSLD showed statistically significant result with higher measurement (p<0.05).

Web-based Personal Dose Management System for Data Recording on Dosimeter Usage: A Case of Tanzania Atomic Energy Commission

  • Mseke, Angela;Ngatunga, John Ben;Sam, Anael;Nyambo, Devotha G.
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.2
    • /
    • pp.15-22
    • /
    • 2022
  • Modern technology drives the world, increasing performance while reducing labor and time expenses. Tanzania Atomic Energy Commission (TAEC) tracks employee's levels of exposure to radiation sources using dosimeters. According to legal compliance, workers wear dosimeters for three months and one month at the workplace. However, TAEC has problems in tracking, issuing and returning dosimeters because the existing tracking is done manually. The study intended to develop a Personal Dose Management System (PDMS) that processes and manages the data collected by dosimeters for easy and accurate records. During the requirements elicitation process, the study looked at the existing system. PDMS' requirement gathering included document reviews, user interviews, and focused group discussions. Development and testing of the system were implemented by applying the evolutionary prototyping technique. The system provides a login interface for system administrators, radiation officers, and Occupational Exposed Workers. The PDMS grants TAEC Staff access to monitor individual exposed workers, prints individual and institutional reports and manages workers' information. The system reminds the users when to return dosimeters to TAEC, generate reports, and facilitates dispatching and receiving dosimeters effectively. PDMS increases efficiency and effectiveness while minimizing workload, paperwork, and inaccurate records. Therefore, based on the results obtained from the system, it is recommended to use the system to improve dosimeter data management at the institution.

Development of Radiation Dosimeter on P Channel Power MOSFET for $\gamma$-rays Real-Time Detection ($\gamma$선 실시간 검출을 위한 P채널 Power MOSFET 방사선 선량 시스템 개발)

  • Han, Sang-Hyun;Ji, Yong-Kun;Kwon, O-Sang;Min, Hong-Ki;Lee, Eung-Hyuk
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.213-223
    • /
    • 2000
  • It is necessary that radiation dose would be detect exactly generated from facility related to nuclear, space, radiotherapy center, etc. This paper is to use of the radiation-induced threshold voltage change as an accumulated radiation dose monitoring sensor. Commercial P Channel Power MOSFET(metal oxide field effect transistor) were tested in a Co-60 gamma irradiation facility to see their capabilities as a radiation dosimeter. We found that the transistors showed good linearity in their threshold voltage shift characteristics with radiation dose. The results demonstrate the potential use of commercial P Channel Power MOSFET as inexpensive radiation sensors.

  • PDF