• Title/Summary/Keyword: Radial Distribution System

검색결과 238건 처리시간 0.03초

배전계통 부하조류계산 알고리즘 비교 분석 (Load Flow Algorithm Analysis of Distribution System)

  • 곽도일;김태응;류재홍;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.134-136
    • /
    • 1999
  • Not much work has been carried out on the load flow analysis of distribution networks. This paper introduces Newton-Raphson method using Distflow equation and Forward Sweeping method in the distribution networks. And that efficient solution scheme in a radial distribution network is presented. Also, simulation results of both Newton-Raphson method and Forward Sweeping method applied to a 22.9kV distribution system model with 120 load buses are analized and evaluated.

  • PDF

Optimal Allocation of Distributed Solar Photovoltaic Generation in Electrical Distribution System under Uncertainties

  • Verma, Ashu;Tyagi, Arjun;Krishan, Ram
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1386-1396
    • /
    • 2017
  • In this paper, a new approach is proposed to select the optimal sitting and sizing of distributed solar photovoltaic generation (SPVG) in a radial electrical distribution systems (EDS) considering load/generation uncertainties. Here, distributed generations (DGs) allocation problem is modeled as optimization problem with network loss based objective function under various equality and inequality constrains in an uncertain environment. A boundary power flow is utilized to address the uncertainties in load/generation forecasts. This approach facilitates the consideration of random uncertainties in forecast having no statistical history. Uncertain solar irradiance is modeled by beta distribution function (BDF). The resulted optimization problem is solved by a new Dynamic Harmony Search Algorithm (DHSA). Dynamic band width (DBW) based DHSA is proposed to enhance the search space and dynamically adjust the exploitation near the optimal solution. Proposed approach is demonstrated for two standard IEEE radial distribution systems under different scenarios.

불평형 배전계통에 있어서 유전알고리즘을 이용한 커패시터의 적정 배치 및 제어 (Optimal Capacitor Placement and Control using Genetic Algorithms in Unbalanced Distribution Systems.)

  • 김규호;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.839-846
    • /
    • 1999
  • This paper presents an efficient algorithm for determining the location, size and number of capacitors in unbalanced radial distribution system. The objective function formulated consists of two terms: cost for energy loss and cost related to capacitor purchase and capacitor installation. The cost function associated with capacitor placement is considered as step function due to banks of standard discrete capacities. Genetic algorithms(GA) are used to obtain the population is derived. The strings in each population consist of the bus number index and size of capacitors to be installed. In order to determine the number of capacitor placement, the length mutation operator is used. Its efficiency is proved through the application in unbalanced radial distribution systems made of 10 buses with 9 distribution lines and 25 buses with 24 distribution lines.

  • PDF

이중 입도 분포를 가진 현탁액의 침강 속도 예측 (Prediction of Hindered Settling Velocity of Bidisperse Suspensions)

  • 구상균
    • 공업화학
    • /
    • 제19권6호
    • /
    • pp.609-616
    • /
    • 2008
  • 본 연구는 크기가 다른 두 종류의 입자를 가진 비(非)콜로이드성 현탁액의 평균 침강 속도를 예측하는 수치적 방법을 제공한다. 이 방법은 무수히 많은 입자들이 유체에 불규칙적으로 분포된 현탁액 시스템의 유체 속도, 온도 등의 물리량을 앙상블 평균의 개념을 사용해서 표현하는 유효 매체 이론에 기초한다. 본 연구에서는 Acrivos와 Chang[1]이 단일(單一) 입도 현탁액에 대해 제안한 모델을 이중(二重) 입도 현탁액에 응용한다. 구체적으로 방사 분포 함수(radial distribution function)에 대한 계산과 stream function을 이용하여 침강 속도를 계산하고 그 결과를 Davis와 Birdsell[2]과 Cheung 등[3]의 실험 결과와 비교하였다. 그 결과 본 연구의 모델에 의한 예측이 실험 결과와 일치하는 것으로 나타났다.

Multi-objective Unbalanced Distribution Network Reconfiguration through Hybrid Heuristic Algorithm

  • Mahendran, G.;Sathiskumar, M.;Thiruvenkadam, S.;Lakshminarasimman, L.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.215-222
    • /
    • 2013
  • Electrical power distribution systems are critical links between the utility and customer. In general, power distribution systems have unbalanced feeders due to the unbalanced loading. The devices that dependent on balanced three phase supply are affected by the unbalanced feeders. This necessitates the balancing of feeders. The main objective of reconfiguration is to balance the loads among the phases subject to constraints such as load flow equations, capacity and voltage constraints and to reduce the real power loss, while subject to a radial network structure in which all loads must be energized. Therefore, the distribution system reconfiguration problem has been viewed as multi-objective problem. In this paper, the hybrid heuristic algorithm has been used for reconfiguration, which is the combination of fuzzy and greedy algorithms. The purpose of the introduction of greedy is to refrain the searching for the period of phase balancing. The incorporation of fuzzy helps to take up more objectives amid phase balancing in the searching. The effectiveness of the proposed method is demonstrated through modified IEEE 33 bus and modified IEEE 125 bus radial distribution system.

운전점에 따른 3차원 소형축류홴의 와도 특성에 대한 대규모 와 모사 (Large Eddy Simulation on the Vorticity Characteristics of Three-Dimensional Small-Size Axial Fan with Different Operating Points)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제20권6호
    • /
    • pp.64-70
    • /
    • 2016
  • The unsteady-state, incompressible and three-dimensional large-eddy simulation(LES) was carried out to evaluate the vorticity distribution of a small-size axial fan(SSAF). The X-component vorticity profiles developed around blade tips turn from axial to radial, and diminish the density of distribution according to the increase of static pressure. Otherwise, the Z-component vorticity profiles evenly develop at the region larger than the half radial distance of blade at the operating points of A and B, partly at the trailing-edge region of blade and radially over bellmouth according to the increase of static pressure.

손실최소화를 위한 배전계통 재구성의 Tabu Search 기법 적용 (Tabu Search Method Applied to Distribution Systems Reconfiguration for Loss Minimization)

  • 장경일;최상열;신명철;남기영;박남옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1459-1461
    • /
    • 1999
  • Distribution systems is consist of network in physical aspect, and radial in electrical aspect. Therefore, radial operation is realized by changing the status of sectionalizing switches, and is usually done for loss reduction in the system. In this paper, we propose a optimal method for distribution systems reconfiguration. Specifically, we use K-optimal algorithm and tabu search method to solve distribution systems reconfiguration for loss minimization problem.

  • PDF

유전알고리즘을 이용한 배전계통의 손실 최소화에 관한 연구 (A Study with Genetic Algorithm Applied to Distribution Systems Reconfiguration for Loss Minimization)

  • 윤창대;최상열;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.330-332
    • /
    • 2001
  • Distribution systems is consist of network in physical and radial in electrical aspect. Therefore radial operation is realized by changing the status of sectionalizing switches, and is usually done for loss reduction in the system. In this paper, we propose a optimal method for distribution systems reconfiguration. Specifically we use genetic algorithm method to solve distribution systems reconfiguration for loss minimization problem. A genetic algorithm(GA) is set up, in which some improvements are made on string coding, fitness function and mutation pattern. As a result, premature convergence is avoided.

  • PDF

신재생에너지원이 연계된 22.9[kV] 배전계통의 양방향 리클로저와 섹셔널라이저 보호협조 방안 (A study of the directional recloser and sectionalizer protective coordination at 22.9[kV] distribution system with new renewable energy generation)

  • 이연화;최준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.525-526
    • /
    • 2007
  • Recently, there has been growing interest in utilizing distributed generation (DG). However, an insertion of DG to existing distribution system can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc,. The typical protection system of the existing distribution system is designed for radial network. But penetration of DG to distribution system changes existing unidirectional power flow to bidirectional power flow. Therefore, investigation to cover whole field of distribution system must be accomplished such as changing of protection devices rating by increasing fault current, reevaluation of protective coordination. This paper presents that PSCAD/EMTDC simulations was accomplished to analyze effect of DG on the distribution protective coordination. In addition, directional recloser-sectionalizer coordination are evaluates distribution system with DG by using PSCAD/EMTDC simulation.

  • PDF

분산전원이 연계된 배전계통의 고장특성을 고려한 방향성 보호계전 방식 적용 연구 (Application of Directional Over Current Protection Schemes Considering the Fault Characteristics in the Distribution System with Dispersed Generation)

  • 정원욱;이학주;권성철;채우규
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.97-107
    • /
    • 2010
  • Penetration of distributed generator(DG) to power distribution system can cause malfunction of existing protection schemes. Because grid interconnected DG can contribute fault currents and make bidirectional current flows on the system, fault contributions from DG can cause an interference of protection relay operation. Therefore, over current protection device of the distribution system with DGs need directional protection schemes. In this paper, improved directional protection algorithms are proposed for the distribution system with DG considering their fault characteristics. And than, these directional protection algorithms are tested and validated in various fault conditions. From the simulation results, it can be seen that the proposed directional protection algorithms are practically efficient for the radial distribution system with DG.