A Study on Evacuees Risk Assesment for Application of Spatial Risk Information (공간위험정보를 적용한 대피자 위험성평가에 관한 연구)

  • Hong, Seungbum;Jang, Jae-Soon;Park, Hyun-A;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.8-12
    • /
    • 2015
  • Performance Based Design is evaluating after each calculatiuon ASET and RSET. Risk informaion values such as heat, smoke, toxic gas etc are extracted by FDS in this study. These Risk informaion values by FDS apply Artisoc (evacuation simulator). Building structure made $60m{\times}65m$, exit number is made 2 positions and people in this building are 50 ramdonly. 20 times (case1~case 20) simulated and analysis evacuees risk by evacuated route positions.

Effects of High School Corridor Walking Obstacles on Evacuation Safety (고등학교 복도 보행 장애물이 피난 안전성에 미치는 영향)

  • Lee Soon Beom
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.112-119
    • /
    • 2023
  • This study analyzes the effects of personal lockers, drinking fountains, and all-in-one shutters (hereinafter referred to as "corridor walking obstacles") on evacuation safety to suggest the necessity of operating a more effective educational facility safety certification system. To achieve this purpose, the five-story high school building with the obstacles installed in the corridor has been chosen, and evacuation tests through the Pathfinder Simulation Program have been carried out. When the evacuation exit is designated in the current state, where the students are placed on the 2nd, 3rd, and 4th floors and the corridor walking obstacles are applied as a variable, the required safe egress time (RSET) is 322 seconds. This can lead to dangerous results in the event of a disaster by exceeding the available safe egress time (ASET) standard of 240 seconds by 82 seconds. When students are placed on the 1st, 2nd, and 3rd floors under the same conditions, the RSET is 214.5 seconds, 25.5 seconds lower than the ASET standard, indicating that it is effective in reducing the impact of walking obstacles on evacuation time. The safety management plan for walking obstacles in the corridors is discussed, considering the special characteristics of the school corridors. The results of this study can be used as the necessary data for optimizing evacuation routes in corridors and creating a safe, educational environment.

Performance Based Design Plan for Apartment that Reflects External Effects from Toxicity and Radiant Heat Due to Acrylonitrile Leakage (아크릴로니트릴 누출에 따른 독성, 복사열 및 외부영향에 의한 아파트의 성능위주설계 방안)

  • Seongju Oh;Sanghun Han;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.65-77
    • /
    • 2024
  • This study aims to present a performance based design for apartments through evacuation safety assessment and damage impact assessment due to acrylonitrile leakage. In the evacuation safety evaluation, ASET was analyzed as 25 min or more and 60 min or less when the ventilation rate was once per hour, and RSET was 22.6 min. Evacuation safety is satisfied when the number of ventilation per hour is less than 1, so it is necessary to design the number of ventilation to be 1 or less. In the damage impact assessment, the 0% structural collapse rate due to overpressure was measured to be between 71m and 90m, and the 0% fatality rate due to radiant heat was measured to be between 136m and 353m. Therefore, maintain a safe distance of 353m or more.

Analyses of Scenarios Based on a Leakage of Highly Compressed Air and Fire Anticipated in CAES (Compressed Air Energy Storage) Facility (압축공기에너지저장 시설에서 발생 가능한 압축공기 유출 및 화재 시나리오 분석)

  • Yoon, Yong-Kyun;Ju, Eun-Hye
    • Tunnel and Underground Space
    • /
    • v.25 no.6
    • /
    • pp.568-576
    • /
    • 2015
  • In this study, scenarios based on the leakage of highly compressed air and fire occurrence turned out to be high risks in an operation stage of CAES facility were constructed and estimated. By combining Bernoulli equation with momentum equation, an expression to calculate an impact force of a jet flow of compressed air was derived. An impact force was found to be proportional to the square of diameter of fracture and the pressure of compressed air. Four types of fire scenarios were composed to evaluate an effects that seasonal change and location of fire source have on the spread behavior of smoke. Smoke from the fire ignited in the vicinity of CAES opening descended more quickly below the limit line of breathing than one from the fire occurred 10 m away from CAES opening, which is expected to occur due to a propagation of wave front of smoke. It was shown that a rate of smoke spread of the winter fire is faster than one of the summer fire and smoke from the winter fire spreads farther than one of the summer fire, which are dependent on the direction of air flow into access opening. Evacuation simulation indicated that the required safe evacuation time(RSET) of the summer and winter fires are 262, 670 s each.

Risk Evaluation and Analysis on Simulation Model of Fire Evacuation based on CFD - Focusing on Incheon Bus Terminal Station (CFD기반 화재 대피 시뮬레이션 모델을 적용한 위험도 평가 분석 -인천터미널역 역사를 대상으로)

  • Kim, Min Gyu;Joo, Yong Jin;Park, Soo Hong
    • Spatial Information Research
    • /
    • v.21 no.6
    • /
    • pp.43-55
    • /
    • 2013
  • Recently, the research to visualize and to reproduce evacuation situations such as terrorism, the disaster and fire indoor space has been come into the spotlight and designing a model for interior space and reliable analysis through safety evaluation of the life is required. Therefore, this paper aims to develop simulation model which is able to suggest evacuation route guidance and safety analysis by considering the major risk factor of fire in actual building. First of all, we designed 3D-based fire and evacuation model at a subway station building in Incheon and performed fire risk analysis through thermal parameters on the basis of interior materials supplied by Incheon Transit Corporation. In order to evaluate safety of a life, ASET (Available Safe Egress Time), which is the time for occupants to endure without damage, and RSET (Required Safe Egress Time) are calculated through evacuation simulation by Fire Dynamics Simulator. Finally, we can come to the conclusion that a more realistic safety assessment is carried out through indoor space model based on 3-dimension building information and simulation analysis applied by safety guideline for measurement of fire and evacuation risk.

A Study on Emergency Evacuation Route Planning and USN-Based Induction Activities of Correctional Facilities (교정시설의 비상시 피난경로계획 및 USN기반 대피유도활동에 관한 연구)

  • Park, Joo-Hyung;Park, Jong-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.39-46
    • /
    • 2011
  • In correctional facilities with majority of occupants in custody, the safe evacuation guide without getaway accidents should be very important due to complexity in escape paths. Fire causes are various in correctional facilities, for example, arson fire is a major cause in mental treatment facilities, however, old facilities or carelessness of flammable materials consist of fire causes in jail facilities. Both types of correctional facilities are the same in terms of many casualties from the fire cases. The thesis focus on escape paths and evacuation guide plans on the basis of analysis on fire cases and structural vulnerability, and then an electronic unlocking system is concededly installed for safe evacuation of occupants in custody without getaway accidents. Especially, the effect of the electronic unlocking system is going to be analyzed on the basis of RSET (required safe egress time) in order to realize for the occupants to evacuate safely to the front yard in case of emergency. In conclusion, if electronic security allowed system with USN (Ubiquitous Sensor Networks) technology should be installed in multi-storey correctional buildings, it is proposed that the occupants in custody might be a guided safely without getaway trials.

Study on the Shortening Effect of the Egress Travel Time Based on an Escape Scenarios by Using Shuttle Elevators for Lotte Tall Building's Evacuation Plan (초고층건물 피난계획시 피난용 엘리베이터 이용에 의한 피난소요시간의 단축효과 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.46-54
    • /
    • 2018
  • A total of 19 elevators for evacuation were installed in the Lotte World Tower and it is planned to operate the shuttle using the manual key from five refuge floors to the 1st floor in an emergency. In the event of a fire or other disaster, it is necessary to conduct intensive analysis to determine how much RSET reduction could be achieved using the evacuation elevator compared to the existing evacuation plans. When the optimal transportation sharing ratio by the evacuation elevators was 40% at the Lotte World Tower, the RSET of the evacuation scenario in parallel with the elevators in the entire building was calculated to be 1 hour and 2 minutes. The RSET of a conventional evacuation scenario (Walking along the stairs without using the elevators) was calculated to be 1 hour 29 minutes, therefore, the former evacuation scenario were found to have a shortening effect of approximately 27 minutes compared to the latter. On the other hand, to maintain this effect, each part of the evacuation route using the elevator must have the capability to protect the evacuee from any hazards caused by fires, such as smoke, flame, and radiant heat during the evacuation. Moreover, the evacuation route should be continuous from the residence position of the elevator user to the final evacuation site, and be recognized easily.

Evacuation Time for Performance Based Design (성능 위주 설계를 위한 피난 시간 계산)

  • Jung, Soo-Young;Kim, Tae-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.179-184
    • /
    • 2010
  • 성능 위주 피난 설계에 있어서 요구피난시간(RSET)을 위한 Simulex 등 피난 시뮬레이션 툴이 사용하고 있는 근본적인 데이터베이스, 즉, 시설 및 군중 조건에 따른 이동 변수, 최대 비유동률(Maximum Specific Flows) 및 경계폭(Boundary Layer Width)을 살펴보고, 트래픽 방정식(Traffic Equation)을 통한 계산 사례 즉, 피난자의 이동 속도 계산 사례, 최소 피난 시간 계산 사례 및 총 유동 용량(Flow Capacity) 수식과 계산 사례를 살펴본다.

  • PDF

Fire and Evacuation Analysis in Environmental Energy Facilities (환경에너지 시설내 화재 및 피난해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.84-90
    • /
    • 2019
  • In this study, a fire and evacuation inside an electronic equipment room in environmental energy facilities were conducted and evaluated using a numerical analysis method. In the fire simulation, the visual distance, temperature distribution, and CO concentration distribution were analyzed using FDS. Based on the results, the Pathfinder program, which is an evacuation simulation, was used to calculate the evacuation time of the occupants and derive an evacuation safety evaluation. As a result, the Available safe Egress time (ASET) of P-01 and P-05 was 203.3 and 398.6 s, respectively. For the Required safety Egress time (RSET) results, all evacuees were evacuated at all points and the safety of the evacuee was secured this simulation showed that the safety evaluation is based on the non - operation of the fire - fighting equipment to improve the safety, making it possible to secure better evacuation safety performance owing to the fire of other fire - fighting facilities.