• Title/Summary/Keyword: RMS signal

Search Result 306, Processing Time 0.027 seconds

The changes of electrocardiography and signal-averaged electrocardiography after surgical repair of Tetralogy of Fallot (활로씨 4징의 교정 수술 후 심전도와 신호 평준화 심전도의 변화)

  • Seo, Hye-Eun;Lim, Hae-Ri;Kim, Yeo-Hyang;Hyun, Myung-Chul;Lee, Sang-Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.5
    • /
    • pp.462-468
    • /
    • 2007
  • Purpose : The purpose of this study was to analyze the changes of the late potential of Signal- averaged electrocardiography (SAECG) and Electrocardiography (ECG) parameters during follow up of those who had taken surgical repair of Tetralogy of Fallot (TOF). Methods : Nine patients who had taken surgical repair of TOF since 1985 checked SAECG and standard 12 leads ECG twice in 1999 and 2005 in Kyungpook national university hospital. We evaluated changes of QRS duration, QT interval and JT interval, QRS dispersion, QT dispersion and JT dispersion of standard 12 leads ECG and Filtered QRS (f-QRS), High frequency low amplitude potential (HFLA), Root mean square in terminal 40 ms (RMS) and Mean voltage in terminal 40 ms (MV) of SAECG between in 1999 and 2005. Results : There were significant decrease of JT dispersion ($101.11{\pm}50.11$ vs $71.11{\pm}22.61ms$, P< 0.05) and significant increase of HFLA ($24.67{\pm}13.19$ vs $32.89{\pm}14.21ms$, P<0.05). But there were no significant changes in other parameters. Conclusion : In repaired TOF patients, we evaluated ECG and SAECG to detect possible late complications such as tricuspid regurgitation, right ventricular enlargement, ventricualar arrythmia and sudden death. And there were significant changes of ECG and SAECG in some parameters (JT dispersion, HFLA). But to see the relationships between the changes of these parameters and the long term prognosis, we need to check more patients and longer follow-up.

The Study of Affecting Image Quality according to forward Scattering Dose used Additional Filter in Diagnostic Imaging System (부가필터 사용 시 전방 산란선량에 따른 화질 영향에 대한 연구)

  • Choi, Il-Hong;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Hyong-Hu;Kang, Sang-Sik;Noh, Si-Cheol;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • Recent clinical field utilizes the aluminium filter in order to reduce the low-energy photons. However, the usage of the filter can cause adverse effect on the image quality because of the scattered dose that is generated by X-ray hardening phenomenon. Further, usage of filter with improper thickness can be a reason of dose creep phenomenon where unnecessary exposure is generated towards the patient. In this study, the author evaluated the RMS and the RSD analysis in order to have a quantitative evaluation for the effect of forward scattering dose by the filter on the image. as a result of the study, the FSR and the RSD was increased together with the increasing of thickness of the filter. In this study the RSD means the standard deviation of the mean value is relatively size. It can be understood that the signal-to-noise ratio decreases when the average value is taken as a signal and the standard deviation is judged as a noise. The signal-to-noise ratio can understanding as index of resolution at image. Based on these findings, it was quantitatively verified that there is a correlation of the image quality with the FSR by using an additional filter. The results, a 2.5 mmAl which is as recommended by NCRP in the tube voltage of 70 kVp or more showed the 14.6% on the RSD when the filter was not in used. these results are considered able to be utilized as basic data for the study about the filter to improve the quality of the image.

Design and Performance Analysis of an Off-Axis Three-Mirror Telescope for Remote Sensing of Coastal Water (연안 원격탐사를 위한 비축 삼반사경 설계와 성능 분석)

  • Oh, Eunsong;Kang, Hyukmo;Hyun, Sangwon;Kim, Geon-Hee;Park, YoungJe;Choi, Jong-Kuk;Kim, Sug-Whan
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.3
    • /
    • pp.155-161
    • /
    • 2015
  • We report the design and performance analysis of an off-axis three-mirror telescope as the fore optics for a new hyperspectral sensor aboard a small unmanned aerial vehicle (UAV), for low-altitude coastal remote sensing. The sensor needs to have at least 4 cm of spatial resolution at an operating altitude of 500 m, $4^{\circ}$ field of view (FOV), and a signal to noise ratio (SNR) of 100 at 660 nm. For these performance requirements, the sensor's optical design has an entrance pupil diameter of 70 mm and an F-ratio of 5.0. The fore optics is a three-mirror system, including aspheric primary and secondary mirrors. The optical performance is expected to reach $1/15{\lambda}$ in RMS wavefront error and 0.75 in MTF value at 660 nm. Considering the manufacturing and assembling phase, we determined the alignment compensation due to the tertiary mirror from the sensitivity, and derived the tilt-tolerance range to be 0.17 mrad. The off-axis three-mirror telescope, which has better performance than the fore optics of other hyperspectral sensors and is fitted for a small UAV, will contribute to ocean remote-sensing research.

Analysis of acoustic emission parameters according to failure of rock specimens (암석시편 파괴에 따른 acoustic emission 특성인자 분석)

  • Lee, Jong-Won;Oh, Tae-Min;Kim, Hyunwoo;Kim, Min-Jun;Song, Ki-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.657-673
    • /
    • 2019
  • A monitoring method based on acoustic emission (AE) sensor has been widely used to evaluate the damage of structures in underground rock. The acoustic emission signal generated from cracking in material is analyzed as various acoustic emission parameters in time and frequency domain. To investigate from initial crack generation to final failure of rock material, it is important to understand the characteristics of acoustic emission parameters according to the stress ratio and rock strength. In this study, uniaxial compression tests were performed using very strong and weak rock specimen in order to investigate the acoustic emission parameters when the failure of specimen occurred. In the results of experimental tests, the event, root-mean-square (RMS) voltage, amplitude, and absolute energy of very strong rock specimen were larger than those of the weak rock specimen with an increase of stress ratio. In addition, the acoustic emission parameters related in frequency were more affected by specification (e.g., operation and resonant frequency) of sensors than the stress ratio or rock strength. It is expected that this study may be meaningful for evaluating the damage of underground rock when the health monitoring based on the acoustic emission technique will be performed.

A channel parameter-based weighting method for performance improvement of underwater acoustic communication system using single vector sensor (단일 벡터센서의 수중음향 통신 시스템 성능 향상을 위한 채널 파라미터 기반 가중 방법)

  • Kang-Hoon, Choi;Jee Woong, Choi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.610-620
    • /
    • 2022
  • An acoustic vector sensor can simultaneously receive vector quantities, such as particle velocity and acceleration, as well as acoustic pressure at one location, and thus it can be used as a single input multiple output receiver in underwater acoustic communication systems. On the other hand, vector signals received by a single vector sensor have different channel characteristics due to the azimuth angle between the source and receiver and the difference in propagation angle of multipath in each component, producing different communication performances. In this paper, we propose a channel parameter-based weighting method to improve the performance of an acoustic communication system using a single vector sensor. To verify the proposed method, we used communication data collected from the experiment conducted during the KOREX-17 (Korea Reverberation Experiment). For communication demodulation, block-based time reversal technique which is robust against time-varying channels were utilized. Finally, the communication results showed that the effectiveness of the channel parameter-based weighting method for the underwater communication system using a single vector sensor was verified.

A Multipath Delay Time Detection Method For $\frac{\pi}{4}$ Shift QPSK Modulation Under The Frequency Selective Fading Environment (주파수 선택성 페이딩 환경하에서 $\frac{\pi}{4}$ shift QPSK 변조방식에 대한 다중파의 시간지역 검출법 제안)

  • 조병진;김대영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.10
    • /
    • pp.941-950
    • /
    • 1991
  • channel is severely degraded by multipath delay time spread. In this paper. We propose a simple multipath delay time detection method, which has a merit of in serviceable, yet simple H/W realizability for $\pi/4$ shift QPSK by detecting cross channel interference. A $\pi/4$ shift QPSK signal originally has quadrature channel(Q-ch) component. Thus in order to measure CCI between in-phase channel(I-ch) and quadrature channel(Q-ch), which closely related to multipath delay time, Frequency doubling scheme(frequency doubler) and differential detector is proposed, which makes $\pi/4$ shift QPSK signal look like BPSK and also makes it possible for CCI to be detected at I-ch detector output. To get an information from time varying I-ch output signal under the multipath lading environment, a method for obtaining the mean of the absolute value$(V_{MABS}(t))$ and another one for obtaining the root mean square value$(V_{RMS}(t))$ of CCI are proposed. Furthermore, a relationship between delay spread and CCI is also analyzed. In order to confirm theoretical results, computer simulation has been carried out under the quasi-static and Reyleigh distributed two ray multipath fading environments. A fairly good result was obtained. However it was also shown that this method is sensitive to bandwidth restriction to some extent. In addition, some idea for a simple hardware realization for the frequency doubler are given.

  • PDF

Implementation of a Single Chip CMOS Transceiver for the Fiber Optic Modules (광통신 모듈용 단일 칩 CMOS트랜시버의 구현)

  • 채상훈;김태련
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.9
    • /
    • pp.11-17
    • /
    • 2004
  • This paper describes the implementation of monolithic optical transceiver circuitry being used as a part of the fiber optic modules. It has been fabricated in 0.6 ${\mu}{\textrm}{m}$ 2-poly 3-metal silicon CMOS analog technology and operates at 155.52 Mbps(STM-1) data rates. It drives laser diode to transmit intensity modulated optical signal according to 155.52 Mbps electrical data from system. Also, it receives 155.52 Mbps optical data that transmitted from other systems and converts it to electrical data using photo diode and amplifier. To avoid noise and interference between transmitter and receiver on one chip, layout techniques such as special placement, power supply separation, guard ring, and protection wall were used in the design. The die area is 4 ${\times}$ 4 $\textrm{mm}^2$, and it has 32.3 ps rms and 335.9 ps peak to peak jitter on loopback testing. the measured power dissipation of whole chip is 1.15 W(230 mW) with a single 5 V supply.

Effects of the Width in the Base of Support on Trunk and Lower Extremity Muscle Activation During Upper Extremity Exercise (상지운동 동안 기저면의 넓이 변화가 체간과 하지의 근 활성도에 미치는 영향)

  • Yun, Hye-Seon;Choi, Houng-Sik;Kim, Tack-Hoon;Cynn, Heon-Seock;Lee, Kang-Sung
    • Physical Therapy Korea
    • /
    • v.11 no.3
    • /
    • pp.43-50
    • /
    • 2004
  • This study was designed to determine the effects of different widths in the base of support (BOS) on trunk and lower extremity muscle activation during upper extremity exercise. Twenty-seven healthy male subjects volunteered for this study. Exercises were performed for a total of 10 trials with a load of 10 repetitions maximum (10 RM) for each of the various widths of BOS (10 cm, 32 cm, 45 cm). The width of a BOS is the distance between each medial malleoli when a subject was in a comfortable standing position. Electromyography was used to determine muscle activation. Surface bipolar electrodes were applied over the tibialis anterior, medial gastrocnemius, biceps femoris, rectus femoris, gluteus maximus, upper rectus abdominis, and elector spinae muscle. Electromyographic (EMG) root mean square (RMS) signal intensity was normalized to 5 seconds of EMG obtained with a maximal voluntary isometric contraction (MVIC). The data were analyzed by atwo-factor analysis of variance (ANOVA) with repeated-measures ($3{\times}7$) and Bonferroni post hoc test. The results were as follows: (1) There were significant differences in the width of the BOS (p=.006). (2) The post hoc test showed significant differences with the BOS between 10 cm and 32 cm, between 10 cm and 45 cm and between 32 cm and 35 cm (p=.008, p=.003, p=.011). (3) There was no interaction with the BOS and muscle. (p=.438) There were no significant differences in the muscle activation (p=.215).

  • PDF

Design and Implementation of a 40 Gb/s Clock Recovery Module Using a Phase-Locked Loop with the Clock-Hold Function (클락 유지 기능을 가지는 위상 고정 루프를 사용한 40 Gb/s 클락 복원 모듈 설계 및 구현)

  • Park Hyun;Woo Dong-Sik;Kim Jin-Jung;Lim Sang-Kyu;Kim Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.171-177
    • /
    • 2006
  • A low-cost, high-performance 40 Gb/s clock recovery module using a phase-locked loop(PLL) for a 40 Gb/s optical receiver with the clock-hold function has been designed and implemented. It consists of a clock extractor circuit, an RF mixer and a frequency discriminator for phase/frequency detection, a VC-DRO, a phase shifter, and a clock-hold circuit. The extracted 40 GHz clock is synchronized with a stable 10 GHz VC-DRO. The clock stability and jitter characteristics of the implemented PLL-based clock recovery module are significantly improved as compared with those of the conventional open-loop type clock recovery module with a DR filter. The measured peak-to-peak RMS jitter is about 230 fs. When an input signal is dropped, the 40 GHz clock is maintained continuously by the hold circuit.

PRINCIPAL COMPONENTS BASED SUPPORT VECTOR REGRESSION MODEL FOR ON-LINE INSTRUMENT CALIBRATION MONITORING IN NPPS

  • Seo, In-Yong;Ha, Bok-Nam;Lee, Sung-Woo;Shin, Chang-Hoon;Kim, Seong-Jun
    • Nuclear Engineering and Technology
    • /
    • v.42 no.2
    • /
    • pp.219-230
    • /
    • 2010
  • In nuclear power plants (NPPs), periodic sensor calibrations are required to assure that sensors are operating correctly. By checking the sensor's operating status at every fuel outage, faulty sensors may remain undetected for periods of up to 24 months. Moreover, typically, only a few faulty sensors are found to be calibrated. For the safe operation of NPP and the reduction of unnecessary calibration, on-line instrument calibration monitoring is needed. In this study, principal component-based auto-associative support vector regression (PCSVR) using response surface methodology (RSM) is proposed for the sensor signal validation of NPPs. This paper describes the design of a PCSVR-based sensor validation system for a power generation system. RSM is employed to determine the optimal values of SVR hyperparameters and is compared to the genetic algorithm (GA). The proposed PCSVR model is confirmed with the actual plant data of Kori Nuclear Power Plant Unit 3 and is compared with the Auto-Associative support vector regression (AASVR) and the auto-associative neural network (AANN) model. The auto-sensitivity of AASVR is improved by around six times by using a PCA, resulting in good detection of sensor drift. Compared to AANN, accuracy and cross-sensitivity are better while the auto-sensitivity is almost the same. Meanwhile, the proposed RSM for the optimization of the PCSVR algorithm performs even better in terms of accuracy, auto-sensitivity, and averaged maximum error, except in averaged RMS error, and this method is much more time efficient compared to the conventional GA method.