• Title/Summary/Keyword: RGP Contact lens

Search Result 30, Processing Time 0.023 seconds

The Effects of Plasma Surface Treatment on Fluorosilicone Acrylate RGP Contact Lenses (불화규소 아크릴레이트 RGP 콘택트렌즈의 플라즈마 표면처리 효과)

  • Jang, Jun-Kyu;Shin, Hyung-Sup
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.207-212
    • /
    • 2010
  • Purpose: Rigid gas permeable (RGP) contact lenses, based on fluorosilicone acrylate, were treated with plasma in air. Methods: The chemical compositions were analyzed by using X-ray photoelectron spectroscopy (XPS), the surface morphology and roughness of RGP contact lenses were observed by using atomic force microscopy (AFM), and the wettability changes were estimated by wetting angle measurement. Results: As the contact lenses were treated by the plasma, the F contents decreased significantly, and the O and Si contents increased on the surface. The number of oxygen-containing hydrophilic radicals (C-O and Si-O) increased greatly, the hydrophobic surface decreased, and the wetting angle increased. But the C-O bonds created with exchange of the fluorine did not increase a wettability. The surface compositions were not remarkably changed for the 6 months after plasma treatment, but the wetting angle increased again. Conclusions: It was considered that the improved wettability of the RGP contact lenses of high fluorine content after plasma treatment was affected by the activation of surface, the increase of Si-O, and the decrease of hydrophobic surface.

The Study of the Ultrastructure on the Rigid Gas Permeable Contact Lenses (Rigid Gas Permeable Contact Lenses의 미세구조에 대한 연구)

  • Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.259-262
    • /
    • 1998
  • The Anterior surface and posterior surface of rigid gas permeable(RGP) contact lenses has been studied by scanning electron microscopy. Results point out that the ultrastructure of contact lenses surface was some different on the anterior and posterior surface of RGP. The Quantitative study of surface roughness suggest that the anterior surface was more smooth than the posterior surface. These results suggest that the materials characters appeared the contact lens surface. The morphology of the anterior and posterior surface have different, Maybe, these result have a manufacture processing of the contact lenses. But some surface appeared a foreign body particles.

  • PDF

Fundamentals of Tight fitted Contact Lens Movement (Tight Fit 콘택트렌즈 운동의 기초)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.17-27
    • /
    • 2009
  • Purpose: This review article was written to determine the effects of parameters characterizing a hard contact lens (RGP included), such as BCs, diameters, edge angles, on the time interval for tight fitted lens to return to the equilibrium when it was decentered from blinking. Methods: A mathematical formulation was established to relate or calculate the restoring forces and thickness of lacrimal layer beneath the cornea with the various lens parameters when the tight fitted lens was decentered from blinking. Based on this formulation the differential equations and their numerical solution program were set up to describe the time dependence of the lens on the position and to estimate the time for the lens's return to the equilibrium after blink. Results: It is found that the time interval for the tight fitted lens to return to the equilibrium decreases as either the BC decreases or the diameter increases because both the reduction in BC and increase in diameter result in the increase in the lacrimal layer thickness between the lens and cornea increase which yielded the lowering of the viscous friction in the lens motion. As the edge angle of tight fitted lens increases the time for recentering decreases due to the increase in restoring force without change in lacrimal thickness beneath the lens. In the case of flat fitted hard lens (RGP included), the lacrimal layer thickness under the lens increases as either BC or diameter increases which results in reduction in viscous friction so that the time for the lens's return to the equilibrium were to decrease. The edge angle of flat fitted lens does not affect the lens motion. Conclusions: The effect of BCs on the lens motion (time to approach the equilibrium) was concluded to be significant with both tight and flat fitted lens where its results are contrary with each other. The edge angle of lens only affects the motion in tight fitted lenses.

  • PDF

The Comparative Study on the wettability of the RGP lens multi-purpose solutions(MPSs) (RGP lens 다목적용액의 습윤성에 관한 비교 연구)

  • Park, Hyun-Ju;Goe, Eun-Kyung;Seo, Eun-Sun;Kim, Jai-Min;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.119-127
    • /
    • 2003
  • We measured the effect of wettability of six MPSs for RGP lens. The used MPSs(multipurpose solutions) were OPTI-SOAK(ALCON), SOLO care hard(CIBA Vision), Total care(ALLERGAN), Simplicity(BOSTON). Wetting and Soaking Sol.(Bausch & Lomb) and Aquas-multi(Saehan). These MPSs keeps hydrophilic property of lens surface and increase the effect of cleaning or increase the effect of preservative effect. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. The results showed that every lens was nearby hydrophilic property within $25^{\circ}{\sim}36^{\circ}$. Also, it was differed by various factors. The surface tension showed various differences between 19.8 and 31.3(mN/m). In the viscosity, MPSs represented the highest viscosity between $4^{\circ}C$ and $20^{\circ}C$. It was much higher than compared with the viscosity of soft lens MPS. This experiment could be used to grasping the interaction between solutions used to MPS and the natural endowments of lens and to considering the relations of different factors effecting the wettability.

  • PDF

Denaturation and Inactivation of Antioxidative Enzymes due to Repeated Exposure to UV-B and Inhibitory Effect of RGP Lens (UV-B 반복노출에 따른 항산화효소의 변성 및 활성저하와 RGP렌즈의 차단효과)

  • Byun, Hyun Young;Lee, Eun Jung;Oh, Dae Hwan;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.237-246
    • /
    • 2015
  • Purpose: The present study was conducted to reveal the correlation of structural denaturation and decrease of enzyme activity when the antioxidative enzymes, superoxide dismutase (SOD) and catalase (CAT) were repeatedly exposed to UV-B, and further investigate whether the denaturation and inactivation of those enzymes can be effectively blocked by using UV-inhibitory RGP lens. Methods: Each enzyme solution was prepared from the standardized SOD and CAT, and repeatedly exposed to UV-B of 312 nm for 30 minutes, 1 hour and 2 hours a day over 1, 2, 3, 4 and 5 days. Structural denaturation of SOD and CAT induced by repeat UV-B irradiation was confirmed by the electrophoretic analysis, and their enzyme activity was determined by the colorimetric assay using the proper assay kit. At that time, the change in structure and activity of the antioxidant enzymes directly exposed to UV-B was compared to the case that UV-B was blocked by UV-inhibitory RGP lens. Results: SOD exposed repeatedly to UV-B showed the polymerization pattern in the electrophoretic analysis when it repeatedly exposed for 30 min a day, however, the change of its activity was less than 10%. On the other hand, CAT repeatedly exposed to UV-B reduced size and density of the electrophoretic band which indicated a structure denaturation, and its activity was significantly decreased. In the case that the repeat exposure time was longer, CAT activity was completely lost even though some enzyme band occurred in the electrphoretic analysis. In addition, the degeneration of CAT due to UV-B irradiation was inhibited to some extent by using RGP lens with a UV-B blocking of 63.7%, however, it was not completely inhibited. Conclusions: From these results, it was revealed that the structural denaturation of antioxidative enzymes was not perfectly correlated with the reduction in enzyme activity according to the type of enzyme. It is recommended to minimize the exposure time to UV when wearing contact lens, or wear the contact lenses having UV blocking rate of the FDA Class I blocker or the sunglasses having equivalent UV-blocking rate for reducing the damage of antioxidative enzymes induced by UV.

Color soft contact lens and corneal thickness

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1205-1214
    • /
    • 2019
  • Purpose: To investigate the effect of color soft contact lenses on the corneal thickness in young Korean population. Methods: The subjects consisted of 112 eyes (7 males, 49 females) with the mean age of $20.987{\pm}1.093years$ (range 20-25 years) in young Korean population during 2018. Test was compared the corneal thickness before and after wearing color soft contact lenses. The thinnest cornea thickness(TCT), central cornea thickness(CCT), pupil centre thickness(PCT), superior corneal thickness(SCT),inferior corneal thickness(ICT), medial corneal thickness(MCT), lateral corneal thickness(LCT) of the cornea was measured using the Pentacam pachymetry. The statistically analysis was perform the Shaparo-Wilk test. Results: The right eye was a statistically significant among the CCT,LCT, MCT and TCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. Also the left eye was a statistically significant among the LCT and MCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. However, there was no statistical difference (p>0.5) in the mean PCT between before and after wearing color soft contact lenses. Conclusion: These results suggested that the color soft contact lens wear can the effect the regional thickness of cornea. Therefore, the analysis of corneal topography with Pentacam can provide correct and useful diagnostic information of the morphology of the RGP contact lens fitting and diagnosis of corneal refraction surgery.

The Current State of Lens Care in Contact Lens Wearer (콘택트렌즈 착용에 따른 사용자 실태조사)

  • Ryu, Geun Chang;Kim, In Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.15-20
    • /
    • 2002
  • The Hydroxyethyl methacrylate(HEMA) was developped in 1960's and later the use of contact lenses increased. At present more and more people use RGP contact lenses. Due to the wide range of optical corrections available and due to their high oxygen transmission Japanese and Korean people like them. Nevertheless one of nine CL users(beginners) stopped wearing the CL within the first year. We conducted a survey to evaluate the level of patient compliance in lens care and maintenance and to assess practitioner knowledge of contact lens information. Generally 6% of contact lens wearers drop out per year. The aim of this research was to find out what opticians can do to reduce the drop-out rate by getting information on handling, on general data of the patient and on optical prescription. Lens wearer were asked to complete a 10 question survey that focused on lens care-wear modality, lens replacement, storage, symptoms and case disinfection. There were total 180 participants in the study. Most of contact lens wearers have an inadequate understanding of contact lens care system. Therefore, it is important that contact lens specialists place more emphasis on practitioner education about general contact lens fields and reinforce patient education during the dispensing visit.

  • PDF

A Study on the Change of Corneal Refractive Power before and after Wearing RGP Contact Lenses by Flat Fitting and Alingment Fitting with Diagnostic Method (RGP 콘택트렌즈의 진단적 피팅법에 의한 플랫한 피팅과 얼라인먼트 피팅 착용 전·후 각막 굴절력의 변화에 관한 연구)

  • Lee, Dae-Won;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Purpose: This study is for compared the change of corneal refractive power before and after wearing of rigid gas permeable contact lense with diagnostic method which is 1 D flatter than alignment fitting on right eye and alignment fitting on left eye for 2 months and investigate the preference. Methods: Twenty middle school and high school students (40 eyes) who had never worn a contact lense before for no corneal topographical change, no ocular disease, no experience of ophthalmic surgery and have normal tear amount were selected for this study and corneal refractive power were examined before wearing rigid gas permeable contact lense and adaptation status and corneal examination were performed after 10 days of wearing and after cheking up the continuation of wearing, all candidate wear contact lens 8 hours per day for 2 month and corneal refractive power were compared. Results: After 2 months of wearing with 1 D flatter than the alignment fitting on right eyes, there was significant difference in the central corneal refractive power was $43.84{\pm}1.33D$, flat K power was $43.05{\pm}1.29D$, and steep K power was $44.61{\pm}1.42D$ decreased than before wearing (p<0.001, 0.001, 0.047). The e-value of the principal meridians also shows statistically significant difference (p=0.037, 0.015). After 2 months of wearing with alignment fitting on left eyes, the central corneal refractive power was $44.40{\pm}1.26D$, flat K power was $43.57{\pm}1.23D$. and flat K e-value was $0.58{\pm}0.05$ which showed no statistically significant difference (p = 0.769, 0.614, 0.181). But steep K power was $45.25{\pm}1.36$, and steep K e-value was $0.45{\pm}0.18$ which shows statistically significant difference (p=0.018, 0.027). Conclusions: Consider the comfort, clear vision, dryness for preference fitting investment, 6 students (30%) prefer right eye which is 1 D flatter fitting, 14 students (70%) prefer left eye which is alignment fitting. For rigid gas permeable fitting needed for accurate examination and should prescribe the alignment fitting which is suitable for each cornea.

Study in Radius of Corneal Curvature of university Students with Keratometer (RGP 렌즈 착용한 대학생의 각막곡률반경 측정)

  • Kim, Chang-Sik;Ryu, Kwang-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.181-185
    • /
    • 2006
  • The measurement of the radius of corneal curvature with keratometer was followed in 184 university students who wearing RGP contact lens and consisted of female(167), male(17) and keratoconus patients(3). Overall mean value in the radius of corneal curvature is 7.77mm, and right and left eyes is appeared the same mean value. Overall mean value in horizontal and vertical is 7.88mm and 7.65mm. Horizontal means is larger than vertical means by 0.22mm of the all female and male students. Male's mean value in the radius of corneal curvature(7.84mm) is larger than female's by 0.08mm, and right and left eyes is also the same mean value. Keratoconus patients' mean value in the radius of corneal curvature(6.86mm) is smaller than others students by 0.91mm.

  • PDF

Analysis on the corneal thickness and anterior chamber depth of the Keratoconus using Pentacam

  • Kim, Douk-Hoon;Sapkota, Kishor
    • Journal of Korean Clinical Health Science
    • /
    • v.6 no.1
    • /
    • pp.1089-1096
    • /
    • 2018
  • Purpose: To investigate the corneal thickness and anterior chamber depth (ACD) of eyes with Keratoconus in the Korean population with the Pentacam. Methods: The subjects consisted of 84 eyes from Keratoconic adults aged 7-59 years during 2010. The thinnest area, apex zone, and pupil centre of the corneal thickness were measured using the Pentacam pachymetry. ACD value was also measured with Pentacam. Results: There was a statistically significant relationship between thickness of the cornea at the apex area and the pupil centre (p=0.0001). However, there was no statistical difference (p>0.5) in the mean thickness of thinnest area, apex zone, pupil centre of cornea between right eye and left eye. Also, correlation between ACD and corneal thickness in all subjects had no statistical differences (p>0.05) in all subjects. Conclusion: These results suggested that the regional thickness of cornea and ACD with Pentacam can provide correct and useful diagnostic information of the morphology of Keratoconus for the RGP contact lens and diagnosis of abnormal corneal refraction surgery.