The Study of the Ultrastructure on the Rigid Gas Permeable Contact Lenses

Rigid Gas Permeable Contact Lenses의 미세구조에 대한 연구

  • Received : 1998.11.30
  • Published : 1998.12.31

Abstract

The Anterior surface and posterior surface of rigid gas permeable(RGP) contact lenses has been studied by scanning electron microscopy. Results point out that the ultrastructure of contact lenses surface was some different on the anterior and posterior surface of RGP. The Quantitative study of surface roughness suggest that the anterior surface was more smooth than the posterior surface. These results suggest that the materials characters appeared the contact lens surface. The morphology of the anterior and posterior surface have different, Maybe, these result have a manufacture processing of the contact lenses. But some surface appeared a foreign body particles.

RGP 콘택트렌즈의 전방과 후방 표면에 대한 것을 주사전자현미경을 이용해서 조사하였다. 그 결과 렌즈의 미세구조에 대한 것은 전면과 후방면에 약간의 차이가 있음을 알 수 있었다. 표면의 거칠음정도는 후방표면보다 전방 표면이 약간 심하게 나타났다. 이런 현상은 아마도 콘택트렌즈의 재료의 특성이라 여겨진다. 한편 전방과 후방 표면의 형태적인 차이인 계곡과 선상은 약간 다르게 나타났다. 이 같은 현상은 렌즈의 제조과정에서 생긴 것으로 생각된다. 그러나 각 표면의 구형의 다양한 입자들은 아마도 렌즈의 제조과정에서 형성된 이물질이라 여겨진다.

Keywords