Study in Radius of Corneal Curvature of university Students with Keratometer

RGP 렌즈 착용한 대학생의 각막곡률반경 측정

  • Kim, Chang-Sik (Dept, of ophthalmic optics, Wonkwang health science college) ;
  • Ryu, Kwang-Min (Dept, of ophthalmic optics, Wonkwang health science college)
  • 김창식 (원광보건대학 안경광학과) ;
  • 류광민 (원광보건대학 안경광학과)
  • Received : 2006.04.18
  • Published : 2006.07.31

Abstract

The measurement of the radius of corneal curvature with keratometer was followed in 184 university students who wearing RGP contact lens and consisted of female(167), male(17) and keratoconus patients(3). Overall mean value in the radius of corneal curvature is 7.77mm, and right and left eyes is appeared the same mean value. Overall mean value in horizontal and vertical is 7.88mm and 7.65mm. Horizontal means is larger than vertical means by 0.22mm of the all female and male students. Male's mean value in the radius of corneal curvature(7.84mm) is larger than female's by 0.08mm, and right and left eyes is also the same mean value. Keratoconus patients' mean value in the radius of corneal curvature(6.86mm) is smaller than others students by 0.91mm.

각막곡률반경은 RGP 렌즈를 착용한 대학생(1980~1984년)을 대상으로 측정하였다. 대상자는 187명으로 여자(167), 남자(17) 그리고 원추각막환자(3)이었다. 각막곡률반경은 전체대상자의 평균치가 7.77mm이었고, 좌안과 우안의 측정치 역시 7.77mm이었다. 눈의 수평, 수직경선의 측정치는 7.88mm, 7.65mm이었다. 남자와 여자의 경우는 모두가 수평이 수직경선보다 동일하게 0.22mm 크게 조사되었다. 성별에 따른 곡률반경의 차이는 남자의 경우 평균치가 7.84mm으로 여자의 경우보다 0.08mm 정도 크게 측정되었고, 좌, 우안의 크기는 차이가 없었다. 원추각막환자는 곡률반경의 평균치가 6.86mm으로 정상인 조사대상자의 평균치보다 0.91mm 작게 조사되어 차이가 큰 것으로 나타났다.