• Title/Summary/Keyword: RF Noise

Search Result 620, Processing Time 0.027 seconds

A Low-Noise Low Dropout Regulator in $0.18{\mu}m$ CMOS ($0.18{\mu}m$ CMOS 저 잡음 LDO 레귤레이터)

  • Han, Sang-Won;Kim, Jong-Sik;Won, Kwang-Ho;Shin, Hyun-Chol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.6
    • /
    • pp.52-57
    • /
    • 2009
  • This paper presents a low-noise low-dropout linear regulator that is suitable for on-chip integration with RF transceiver ICs. In the bandgap reference, a stacked diode structure is adopted for saving silicon area as well as maintaining low output noise characteristic. Theoretical analysis for supporting the approach is also described. The linear regulator is fabricated in $0.18{\mu}m$ CMOS process. It operates with an input voltage range of 2.2 V - 5 V and provide the output voltage of 1.8 V and the output current up to 90 mA. The measured line and load regulation is 0.04%/V and 0.46%, respectively. The output noise voltage is measured to be 479 nV/$^\surd{Hz}$ and 186 nV/$^\surd{Hz}$ from 100 Hz and 1 kHz offset, respectively.

Design of EMC countermeasures for radar signal processing board (레이다 신호처리 보드의 EMC 대책 설계)

  • Hong-Rak Kim;Man-hee Lee;Youn-Jin Kim;Seong-ho Park
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.41-46
    • /
    • 2023
  • It is very important to meet the maximum detection range in a radar system. In order to meet the maximum detection Range, the sensitivity of the received signal of the radar system must be high. In addition, the dynamic range should be wide in the radar signal processing board. To meet these requirements, the signal processing board must be designed to be robust against external and internal noise. In particular, a design is required to minimize the effect of noise generated by various switching circuits inside the board on the received radar signal. In this paper, we derive the requirements of the signal processor board to meet the radar system performance and describe the design to meet the derived requirements. In addition, the EMC design to minimize the influence of noise input from the outside or generated from the inside is described. Confirm the secured performance through the test of the manufactured board.

Development of Birdcage RF coil for 3T Animal MR Imaging

  • 추명자;최보영;강세권;최치봉;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.85-89
    • /
    • 2002
  • We authors developed a new small-size birdcage RF coil for animal MR images. And we compared signal-to-noise ratio (SNR) of the new small coil with a conventional knee coil. The dimension of the low-pass type birdcage coil with 12 elements at 37 MRI system are 13 cm outer diameter, 12 cm inner diameter and 20 cm length. For each element, the width of copper tape is 0.05 mm, thickness is 8 mm and length is 20 cm. The small birdcage coil with 12 elements exhibited 7 resonance modes. The isolation of the quadrature channel could be achieved more than 20 ㏈. The coil quality factor (Q value) was 98.6. The SNR of the animal coil was 243.2 on the average and was about twice as high as the conventional knee coil. The present study successfully demonstrated that the small birdcage coil could provide high quality animal MR images with the improved SNR. Therefore, it is expected that the small birdcage coil could be used in the clinical diagnosis and research studies for veterinary medicine in the near future.

  • PDF

Design of the Microwave Oscillator with the C type DGS Resonator (C형태의 DGS 공진기를 이용한 초고주파 발진기 설계)

  • Kim, Gi-Rae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.4
    • /
    • pp.243-248
    • /
    • 2015
  • Since phase noise is one of the most important parameters in the design of microwave oscillators, several methods have been proposed to reduce the phase noise. These methods have focused on improving the quality factor of resonators, which result in low phase noise oscillators. Dielectric resonators have been widely used for low phase noise in microwave oscillators due to their high quality factor. However this cannot be used in MMIC oscillators because they have a 3D structure. In this paper, to overcome this problem a novel resonator using open ring type DGS is proposed for improvement of phase noise characteristics that is weak point of oscillator using planar type microstrip line resonator, and oscillator for 5.8GHz band is designed using proposed DGS resonator. The open ring type DGS resonator is composed of DGS cell etched on ground plane under $50{\Omega}$ microstrip line. At the fundamental frequency of 5.8GHz, 6.1dBm output power and -82.7 dBc@100kHz phase noise have been measured for oscillator with ring type DGS resonator. The phase noise characteristics of oscillator is improved about 96.5dB compared to one using the general ${\lambda}/4$ microstrip resonator.

Packet Acquisition for DS/CDMA-based LEO Satellite communication System (DS/CDMA 저궤도 위성 통신 시스템의 패킷 초기 동기 연구)

  • 김동희;김영초;이상운;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5B
    • /
    • pp.871-878
    • /
    • 2000
  • A divided matched filter-reference filter(MF-RF) technique for LEO satellite packet transmission is proposed to increase the packet throughput in the presence of severe Doppler shift and fading. To overcome the severe Doppler shift, the divided matched filter is adopted where the integration region of matched filter is divided and ouputs of divided matched filer are added to decide the correct pseudo-noise (PN) phase. To maintain the constant false alarm rate in time varying interference and fading channel, the adaptive threshold for acquisition is obtained from the reference filter. As a performance measure, average acquisition time and packet throughput are used, and the effets of the parameters, i.e., Doppler shift, chip energy to noise ratio, user velocity, standard deviation of shadowing, and preamble length are shown.

  • PDF

16-QAM OFDM-Based W-Band Polarization-Division Duplex Communication System with Multi-gigabit Performance

  • Kim, Kwang Seon;Kim, Bong-Su;Kang, Min-Soo;Byun, Woo-Jin;Park, Hyung Chul
    • ETRI Journal
    • /
    • v.36 no.2
    • /
    • pp.206-213
    • /
    • 2014
  • This paper presents a novel 90 GHz band 16-quadrature amplitude modulation (16-QAM) orthogonal frequency-division multiplexing (OFDM) communication system. The system can deliver 6 Gbps through six channels with a bandwidth of 3 GHz. Each channel occupies 500 MHz and delivers 1 Gbps using 16-QAM OFDM. To implement the system, a low-noise amplifier and an RF up/down conversion fourth-harmonically pumped mixer are implemented using a $0.1-{\mu}m$ gallium arsenide pseudomorphic high-electron-mobility transistor process. A polarization-division duplex architecture is used for full-duplex communication. In a digital modem, OFDM with 256-point fast Fourier transform and (255, 239) Reed-Solomon forward error correction codecs are used. The modem can compensate for a carrier-frequency offset of up to 50 ppm and a symbol rate offset of up to 1 ppm. Experiment results show that the system can achieve a bit error rate of $10^{-5}$ at a signal-to-noise ratio of about 19.8 dB.

Binary Power Amplifier with 2-Bit Sigma-Delta Modulation Method for EER Transmitter

  • Lim, Ji-Youn;Cheon, Sang-Hoon;Kim, Kyeong-Hak;Hong, Song-Cheol;Kim, Dong-Wook
    • ETRI Journal
    • /
    • v.30 no.3
    • /
    • pp.377-382
    • /
    • 2008
  • A novel power amplifier for a polar transmitter is proposed to achieve better spectral performance for a wideband envelope signal. In the proposed scheme, 2-bit sigma-delta (${\Sigma}{\Delta}$) modulation of the envelope signal is introduced, and the power amplifier configuration is modified in a binary form to accommodate the 2-bit digitized envelope signals. The 2-bit ${\Sigma}{\Delta}$ modulator lowers the noise of the envelope signal by fine quantization and thus enhances the spectral property of the RF signal. The Ptolemy simulation results of the proposed structure show that the spectral noise is reduced by 10 dB in a full transmit band of the EDGE system. The dynamic range is also enhanced. Since the performance is improved without increasing the over-sampling ratio, this technique is best suited for wireless communication with high data rates.

  • PDF

Effects of the length the MSL on the oscillation characteristic of the VCO (VCO의 MSL길이가 발진특성에 미치는 영향)

  • 이동희;정진휘
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.721-724
    • /
    • 2001
  • In this paper, we present the effect the length the MSL(Microstrip Line) on the oscillation characteristic of the fabricated VCOs(Voltage Controlled Oscillator) designed and analyzed by RF circuit simulator Serenade(ANSOFT Co.) and fabricated by screen printing method on the alumina substrate. We have fabricated VCOs with 3 different MSL length and each MSL length of the VCO is 140mi1, 280mil and 560mi1. The oscillation frequency of each sample(VCO) was tuned to UHF band(750MHz∼900MHz) varying the capacitance. The experimental result shows the phase noise -82∼-97[dBc/Hz] at a 50 [kHz] offset frequency, the pushing figure 94∼318[kHz] at 3${\pm}$0.15[V] and the harmonics 13∼21 [dBc] between MSL length 140mi1s and 560mi1. The frequency and output variation width are 779∼898[MHz], -36∼-33[dBm] at MSL length 140mi1; 818∼836[MHz], -27.19∼-27.06[dBm] at 280mi1;751.54∼751.198[MHz],-33.44∼ -33.31[dBm] at 560mi1. we examined 3 VCOs oscillation characteristic difference through comparison with phase noise, oscillation power and frequency by control voltage change, harmonics and pushing figure for each sample.

  • PDF

A Study on a Healthcare System Using Smart Clothes

  • Lim, Chae Young;Kim, Kyungho
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.372-377
    • /
    • 2014
  • Being able to monitor the heart will allow the diagnosis of heart diseases for patients during daily activities, and the detection of burden on the heart during strenuous exercise. Furthermore, with the help of U-health technology, immediate medical action can be taken, in the case of abnormal symptoms of the heart in daily life. Therefore, it appears to be necessary to develop the corresponding technology to monitor the condition of the heart daily. In this study, a novel wearable smart system was proposed, to monitor the activity of the heart in daily life, and to further evaluate the rhythm of arrhythmia. The wearable system includes three modified bipolar conductive fiber electrodes in the chest part, which can resolve the reduction problem of the magnitude of the signal, by magnifying the signal and removing the noise, to obtain high affinity and validity for medical-type usage (<0.903%). The biological signal acquisition and data lines, and the signal processing engine and communication consist of a conductive ink, and the pic18 and ANT protocol nRF24AP2, respectively. The proposed algorithm was able to detect a strong ECG, signal and r-point passing over the noise. The confidence intervals were 96 %, which could satisfy the requirement to detect arrhythmia under the unconstrained conditions.

Performance Analysis of Indoor/Outdoor Visible Light Communication System Influenced by External Noise Light (외부광잡음에 의한 실내외 가시광 무선통신 성능 변화 분석)

  • Yang, Se-Hoon;Kim, Deok-Rae;Kim, Hyun-Seung;Son, Yong-Hwan;Han, Sang-Kook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12B
    • /
    • pp.1595-1600
    • /
    • 2011
  • We analyzed the noise effect from artificial light and sunlight on the signal performance in visible light communication systems based on Intensity Modulation/Direct Detection(IM/DD). System performance was experimentally demonstrated by transmitting 50ksysmbol/s QPSK signals at 2MHz sub-carrier. And received signals were analyzed using EVM and RF spectrum. Finally, the system performance was improved by utilizing a visor and we confirm that the outdoor visible light communication was possible using IM/DD method.