• Title/Summary/Keyword: RBM 처리

Search Result 29, Processing Time 0.024 seconds

COMPARATIVE STUDY OF REMOVAL EFFECT ON ARTIFICIAL PLAQUE FROM RBM TREATED IMPLANT (RBM 처리된 임플란트 표면의 인공치태 제거 효과 연구)

  • Park, Jae-Wan;Kook, Min-Suk;Park, Hong-Ju;Shet, Uttom Kumar;Choi, Choong-Ho;Hong, Suk-Jin;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.4
    • /
    • pp.309-320
    • /
    • 2007
  • Purpose: This study was to evaluate the removal effect on artificial plaque from RBM treated implant surfaces that are exposed due to peri-implantitis. Materials and methods: Artificial plaque with Streptococcus mutans and acquired pellicle adhered to RBM treated implant discs. Study materials divided into one control and six test groups. In test groups, physical and chemical methods used to remove plaques. Prophyflex, Professional Mechanical Tooth Cleaning (PMTC) and interdental brush as mechanical treatments and 0.1% Chlorhexidine, Citric acid, HCl tetracycline as a chemical treatment were used. To analyses the study, disc weight was measured for remaining plaque quantities and SEM(Scanning Electronic Microscope) findings was taken for evaluation of surfaces. Results: 1. In weight changes, there was significant difference between each treatment group and the control group (p<0.05). Therefore all treatment methods using this study have good ability for remove plaques. 2. In weight changes, there was no significant difference between mechanical and chemical group, and there were no significant differences between each groups (p>0.05). 3. SEM findings after mechanical treatment disclosed as follows; Prophyflex group looked like sound implant surface, and there were some paste on implant surface at PMTC group, and there were some artificial plaque at interdental brush group. 4. SEM findings after chemical treatment disclosed as follows; there were some dark lesions which were supposed as the product from Streptococcus mutans at Chlorhexidine, Citric acid and HCl tetracycline groups. Conclusion: All six methods using in this study have good ability to remove artificial plaque on RBM treated implant. According to SEM findings, prophyflex is a superior method for removing of dental plaque among test groups.

Removal Torque of Mg-ion Implanted Clinical Implants with Plasma Source Ion Implantation Method (마그네슘 이온주입 임플란트의 뒤틀림 제거력에 관한 연구)

  • Kim, Bo-Hyoun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.41-52
    • /
    • 2009
  • The surface treatment of titanium implant could bring out the biochemical bonding between bone and implant. The purpose of this study was to evaluate the biomechanical bone response of Mg-ion implanted implants with plasma source ion implantation method. Twelve New Zealand white rabbits were included in this study. Each rabbit received one control fixture (blasted with resorbable blasting media, RBM) and three types of Mg ion implanted fixtures in tibiae. The implants were left in place for 6 weeks before the rabbits were sacrificed. Removal torque value and resonance frequency analysis (ISQ) were compared. The repeated measured analysis of variance was used with $P{\leq}0.05$ as level of statistical significance. ISQ was not different among all groups. However, the ISQ was increased after 6 weeks healing. The group had lowest ISQ value showed the greatest increment. Mg-1 implants with 9.4% retained ion dose showed significantly higher removal torque value than that of the other implants. From this results, it is concluded that the Mg-1 implants has stronger bone response than control RBM surface implant.

COMPARATIVE STUDY OF OSSEOINTEGRATION OF 4 DIFFERENT SURFACED IMPLANTS IN THE TIBIA OF DOGS (성견 경골에서 표면처리방법이 다른 4종의 임프란트 골유착에 관한 비교연구)

  • Hong, Who-Suk;Kim, Tae-Hee;Ryu, Seong-Hee;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.1
    • /
    • pp.46-54
    • /
    • 2005
  • Purpose: This study was performed in order to compare the osseointegration of 4 different surfaced implants in the dog's tibia which has thick dense cortical bone and loose marrow space. Materials & methods: Four mongrel dogs and four different surface types of implants, smooth surfaced AVANA implants, RBM surfaced AVANA implants, HA-coated Steri-Oss implants and SLA Bicon implants, were used in this study. The animals were divided into 4 groups on the basis of implant surface characteristics: Control group, RBM group, HA group, and SLA group. Three implants of each group were installed into the metaphysis of tibia of adult dogs. The animals were sacrificed at 8 weeks after implantation. The undecalcified specimens were prepared for histological examination and histomorphometric analysis of implant-bone contact ratios. Results: Radiographically and histologically good osseointegration of implant was observed in the dense cortical bone, but poor osseointegration was observed in the marrow space. Histologically more bone apposition to implant surface was found in rough surfaced groups than the smooth surfaced, Control group. In histomorphometric findings of cortical bone the average bone-implant contact ratios of HA group (95.4%, p<0.01), RBM group (87.1%, p<0.05), and SLA group (86.0%, p<0.05) were significantly higher than that of Control group (75.9%). In marrow space the average bone-implant contact ratios of HA group (76.1%, p<0.01) and SLA group (45.4%, p<0.05) were significantly higher than that of Control group (29.6%). The ratio of RBM group was higher than that of Control group but there was no significantly difference between RBM group and Control group. Conclusion: These results suggest that the rough surfaced implants can obtain the better osseointegration than the smooth surfaced implant in the cortical and marrow space and that HA-coated implants can obtain the best osseointegration in the marrow space among them.

EFFECT OF VARIOUS INODIZING CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANT SURFACE DESIGN (다양한 양극산화막 처리방법이 임프란트 골유착에 미치는 영향)

  • Cha, Soo-Ryun;Lee, Jun;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.417-427
    • /
    • 2008
  • The aim of this study is to investigate the effect of anodizing surface to osseointegration of implant by using of resonance frequency analysis (RFA), quantitative and qualitative assessment of an anodically modified implant type with regard to osseous healing qualities. A total of 96 screw-shaped implants were prepared for this study. 72 implants were prepared by electrochemical oxidation with different ways. 24 (group 1 SP) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid. 24 (group 2GC) were prepared at galvanostatic mode in calcium glycerophosphate and calcium acetate and 24 (group 3 CMP (Calcium Metaphosphate) Coating were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid followed by CMP coating. Rest of 24 (control group were as a control group of RBM surface. Bone tissue responses were evaluated by resonance frequency analysis (RFA) that were undertaken at 2, 4 and 6 weeks after implant placement in the mandible of mini-pig. Group 1 SP (anodized with sulfuric acid and phosphoric acid implants) demonstrated slightly stronger bone responses than control Group RBM. Group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) demonstrated no difference which were compared with control group. Group 3 GMP (anodized and CMP coated implants) demonstrated slightly stronger and faster bone responses than any other implants. But, all observation result of RF A showed no significant differences between experimental groups with various surface type. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact for group 2 GC. Significantly more bone formation was found inside threaded area for group 2 GC. It was concluded that group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) showed more effects on the bone tissue responses than RBM surface in initial period of implantation. In addition, CMP showed a tendency to promote bone tissue responses.

THE EFFECT OF SURFACE TREATMENT OF THE CERVICAL AREA OF IMPLANT ON BONE REGENERATION IN MINI-PIG (미니돼지에서 발치 후 즉시 임플란트 매식시 치경부 표면처리가 골재생에 미치는 효과)

  • Cho, Jin-Yong;Kim, Young-Jun;Yu, Min-Gi;Kook, Min-Suk;Oh, Hee-Kyun;Park, Hong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.285-292
    • /
    • 2008
  • Purpose: The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. ${\phi}$3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was $2.66{\pm}0.11$ mm at US II implants group and $1.80{\pm}0.13$mm at US II plus implant group. The P-B distance after 4 months of healing was $2.29{\pm}0.13$mm at US II implants group and $1.25{\pm}0.10$mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

FOUR-YEAR SURVIVAL RATE OF RBM SURFACE INTERNAL CONNECTION NON-SUBMERGED IMPLANTS AND THE CHANGE OF THE PERI-IMPLANT CRESTAL BONE (RBM 표면처리 내부연결형 비매립 임플란트의 4년 생존율과 주변골 흡수에 관한 임상 및 방사선학적 연구)

  • Jeon, Hye-Ran;Kim, Myung-Rae;Lee, Dong-Hyun;Shin, Jung-Sub;Kang, Na-Ra
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.3
    • /
    • pp.237-242
    • /
    • 2009
  • Implant-supported fixed and removable prostheses provide a proper treatment modality with reliable success. The SS $II^{(R)}$ Implants is a one-stage nonsubmerged threaded titanium implants with Resorbable Blasting Media (RBM) surface developed by Osstem company (Busan, Korea) in October of 2002. This study is to evaluate the survival rate of the SS $II^{(R)}$ Implants for 4 years using radiographic parameters and to review the retrieved implants by the cytotoxicity tests. Since September 2003, 439 SS $II^{(R)}$ implants had been used for 173 patients at Ewha Womans University Medical Center in Korea. Patients consisted of 91 females (52.6 %) and 82 males (47.4 %). The patients' mean age was $42\;{\pm}16$ years, ranging from 21 to 83 years. The follow-up period ranged from 9 to 46 months (mean F/U $24.2\;{\pm}\;10.2$ months). The results are as follows; 1. Of 439 implants, 17 implants were removed and 4-year cumulative survival rate was 96.1%. 2. 82.3% of 17 failed implants were founded during healing phase, and 94.1% of failed fixtures were removed within 5 months after implantation. 3. Crestal bone around the implants was resorbed to 1 mm in 89.0%, to 1 - 2 mm loss of the marginal bone in 8.3%, and the bone loss over 2 mm was occurred in 2.7%. 4. Microscopic examination of the retrieved implants disclosed Grade 0 cytotoxicity in 4 and Grade 1 cytotoxicity in 2 of 6 groups divided according to LOT numbers. Inhibition rate with optical density was acceptable as low as ISO standard.

MULTICENTER RETROSPECTIVE STUDY OF IMMEDIATE TWO DIFFERENT RBM SURFACED IMPLANT SYSTEMS AFTER EXTRACTION (발치 후 즉시 매식된 서로 다른 두종의 RBM표면 처리된 임플란트에 대한 다기관 후향적 임상연구)

  • Park, Hong-Ju;Kook, Min-Suk;Kim, Su-Gwan;Kim, Young-Kyun;Cho, Yong-Seok;Choi, Gab-Lim;Oh, Young-Hak;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.258-265
    • /
    • 2008
  • Purpose. This multicenter retrospective study was performed to evaluate the survival and success rates of immediate placement of USII and SSII Osstem implant (Osstem implant Co, Korea) on the maxillary and mandibular anterior and premolar areas. Materials and methods. Dental records were obtained in 37 patients who were treated with immediate implantation on the maxillary and mandibular anterior and premolar areas in 6 different clinics. The 98 implants were evaluated both clinically and radiographically using predefined success criteria. Results. There was no failed implant in all patients. The mean follow up period was 24.7 months (ranged from 12 to 58 months), and 25.1 months (ranged from 16 to 35 months) in USII and SSII implants, respectively. The crestal bone loss was 3 mm in 3 USII implants during 41 months, and in 1 SSII implant during 22 months. The overall success rate was 94.2% and 97.7% in USII and SSII implants, respectively. The age, gender, diameter, or length of implants, and type of surgery were not influenced to the success rate of immediate implantation. Conclusion. These results suggest that USII and SSII Osstem implant can be used successfully in immediate implantation on the maxillary and mandibular anterior and premolar areas.

Success rate and marginal bone loss of Osstem USII plus implants; Short term clinical study (Osstem USII plus 임플란트의 단기간 성공률 및 변연골 흡수량 평가)

  • Kim, Sun-Keun;Kim, Jee-Hwan;Lee, Keun-Woo;Cho, Kyoo-Sung;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.206-213
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the clinical value of Osstem$^{(R)}$ USII plus system implants. Clinical and radiographic data were analyzed for 88 implants placed and functionally loaded for a 12 month period at the Yonsei University Dental Hospital. Materials and Method: Based on the patient's medical records, clinical factors and their effects on implant marginal bone resorption, distribution and survival rate were analyzed. The marginal bone loss was evaluated at implant placement and during a 6 to 12 months functional loading period. The independent sample t-test was used to evaluate the interrelationship between the factors (${\alpha}$=0.05), and one way repeated measures ANOVA was used to compare the amount of marginal bone resorption. Results: The cumulative survival rate for 88 implants was 100%. The marginal bone resorption from implant placement to prosthetic delivery was 0.24 mm and the average marginal bone resorption from prosthetic delivery to 12 months of functional loading was 0.19 mm. The total average bone resorption from implant placement to 12 months of functional loading was 0.43 mm. There were no statistically differences in the amount of marginal bone resorption when implants were placed in the maxilla or the mandible (P>.05), however, implants placed in the posterior areas showed significantly more marginal bone loss than those placed in the anterior areas (P<.05). Conclusion: Based on these results, the short term clinical success rate of RBM surface treated external connection domestic implants showed satisfactory results and the marginal bone loss was in accord with the success criteria of dental implants.

Comparison of the SNR in the MR images on dental implant material (치아 임플란트 재료에 따른 자기공명영상의 SNR 비교)

  • Kim, Dong-Hyun;Ko, Seong-Jin;Ye, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.149-155
    • /
    • 2015
  • Tooth implant is located in oral cavity and affects neck, skull base, and facail image. These magnetic inhomogeneities are usually frequency encoding direction which cause artifacts due to change of signal strength and geometric distortion. First, to evaluate signal to noise ratio (SNR) of magnetic resonance image caused by tooth implant this study uses meat phantom which is similar to human body and is consisted with fat, muscle, and water to measure signal to noise ratio. Second, signal to noise ratio by using custom-made fixed phantom is measured, and then signal to noise ratio size of different tooth implant types is compared and analyzed. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for meat phantom were 2.76, 2.22, 1.88, and 1.57 on T1 SE, 1.88, 1.78, 1.65, and 1.79 on T2 FLAIR, 2.28, 2.25, 2.88, and 2.05 on T2 FSE, and 2.74, 1.94, 1.67, and 1.48 on T2 GRE. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for fixed water phantom were 1.2, 1.06, 1.12, and 1.22 on DWI, 1.93, 1.87, 1.93, and 2.06 T1 SE, 1.83, 1.76, 1.82, and 1.92 on T2 FLAIR, 1.85, 1.79, 7.86, and 1.97 on T2 FSE, and 1.97, 1.93, 1.99, and 2.06 on T2 GRE. By considering through the results, patients and dentists need to consider some impacts from testing many aspects although their main purpose of having tooth implants is a dental restoration. Moreover, depending on the tooth implant characteristics of individual patients this study results can be used as baseline data when choosing test protocol.

Raman and Photoluminescence Study of Single-Walled Carbon Nanotubes Dispersed in Sodium Dodecyl Sulfate Aqueous Solution Using Ultrasonication (계면활성제를 이용한 단층 탄소나노튜브 분리에 따른 라만과 Photoluminescence 연구)

  • Park, June;Seong, Maeng-Je
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.2
    • /
    • pp.170-174
    • /
    • 2008
  • We have studied, using Raman and photoluminescence (PL) spectroscopy, material property changes of single-walled carbon nanotubes (SWCNTs) dispersed in sodium dodecyl sulfate(SDS) aqueous solution by ultrasonication. Radial breathing mode Raman intensities of the dispersed SWCNTs shows different behavior depending on their chiralities as the sonication time increases. As the amount of SWCNTs dispersed in 1wt% SDS solution increases, both a downshift of the G-band Raman frequency and an enhancement in the PL intensity were observed.