A study on the optimization of ECAP by processing parameter analysis (공정변수 분석을 통한 ECAP 성형 최적화에 관한 연구)

  • Kim, Kyoung-Tae;Kim, Chang-Kyu;Kim, Tae-Won
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1150-1155
    • /
    • 2008
  • Parameter analysis has been performed for an equal channel angular process. The processing variables such as channel configuration, friction coefficient, and ram speed were investigated by means of the magnitudes and distributions of effective plastic strain analysis through the deformation. The materials considered were pure aluminum and titanium. Here firstly, a finite element implementation by using the commercial ABAQUS software was carried out for both the aluminum and titanium materials based on the L-channel configuration. The experimental investigation then has been conducted using the obtained data. Finally, the ability of robust metals which can be produced by the optimized ECAP has been discussed by the appropriate parameter analysis.

  • PDF

Risk Assessment of Stationary Hydrogen Refueling Station by Section in Dispenser Module (고정식 수소충전소에서의 Dispenser Module 내 구역별 위험성 평가)

  • SangJin Lim;MinGi Kim;Su Kim;YoonHo Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.1
    • /
    • pp.76-85
    • /
    • 2023
  • Demand for hydrogen as a renewable energy resource is increasing. However, unlike conventional fossil fuels, hydrogen requires a dedicated refueling station for fuel supply. A risk assessment of hydrogen refueling stations must be undertaken to secure the infrastructure. Therefore, in this study, a risk assessment for hydrogen refueling stations was conducted through both qualitative and quantitative risk assessments. For the qualitative evaluation, the hydrogen dispenser module was evaluated as two nodes using the hazard and operability (HAZOP) analysis. The risk due to filter clogging and high-pressure accidents was evaluated to be high according to the criticality estimation matrix. For the quantitative risk assessment, the Hydrogen Korea Risk Assessment Module (Hy-KoRAM) was used to indicate the shape of the fire and the range of damage impact, and to evaluate the individual and social risks. The individual risk level was determined of to be as low as reasonably practicable (ALARP). Additional safety measures proposed include placing the hydrogen refueling station about 100m away from public facilities. The social risk level was derived as 1E-04/year, with a frequency of approximately 10 deaths, falling within the ALARP range. As a result of the qualitative and quantitative risk assessments, additional safety measures for the process and a safety improvement plan are proposed through the establishment of a restricted area near the hydrogen refueling station.

Comparative Analysis of IEC Standard and Simulation Results for Hydrogen Hazardous Distance (수소 폭발위험범위에 대한 IEC기준과 시뮬레이션 결과의 비교분석)

  • Seung-Hyo An;Eun-Hee Kim;Seon-Hee Lee;Byung-Chol Ma
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.19-26
    • /
    • 2024
  • In workplaces handling flammable gas such as hydrogen, hazardous area is determined through KS C IEC 60079-10-1 standard. Because this standard determines the hazardous distance based on the release characteristic regardless of the type of gas, indoor/outdoor conditions, and atmospheric conditions, concerns are being raised about the effectiveness. In this study, simulations (PHAST, HyRAM) were performed to calculate the hazardous distance for hydrogen under various release characteristics and atmospheric conditions, and compared these results to IEC standard log-log graph. Also, we performed regression analysis according to each result. we found that the simulation results were 0.6 to 3.8 times less than the IEC standard, presented convenient linear regression equations. In addition, We confirmed that the results of hazardous distance varied based on wind velocity and atmospheric stability at the same release characteristic. In addition, we derived linear regression equations for release characteristics and hazardous distance that can be conveniently utilized. So, when classifying hazardous area in workplaces where they handle the hydrogen, the integrated graph and linear regression equation are helpful for confirming the hazardous area. Moreover, it is expected that the economic burden will be minimized by being able to classify reasonable hazardous area and to greatly reduce the risk of hydrogen explosion.

Analysis of haline channel formed in the East China Sea and the Atlantic Ocean using the T-S gradient diagram

  • Kim, Juho;Kim, Hansoo;Paeng, Dong-Guk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.208-216
    • /
    • 2014
  • In case of any coastal ocean near the mouth of huge rivers, low salinity water can be formed due to its large amount of freshwater discharge. For the acoustic analysis on the low salinity environment, some oceanographic data of the East China Sea and the Atlantic Ocean were collected through KODC (Korea Oceanographic Data Center) and NODC (National Oceanographic Data Center) online service. In this paper, the T-S gradient diagram is introduced to show a relation between the gradients of temperature and salinity in view of acoustic surface channel formation. Existence of haline channel, quantitative contribution of gradients of salinity and temperature, effectiveness of the channel formation can be known by the T-S gradient diagram. After applying the collected data into the diagram, tropical regions of the Atlantic Ocean show strong haline channel due to its nearly invariant temperature and drastic change of salinity with depth. The averaged transmission loss in the channel is about 5.7 ~ 7.5 dB less than that out of the channel by the results of acoustic propagation model (RAM: Range independent Acoustic Model). On the other hand, the East China Sea and temperate region of the Atlantic ocean have weaker haline channel with less difference of the averaged transmission loss between in and out of the channel as 3.2 ~ 6.0 dB. Although data samples used in this study have limitation to represent the general physical structures of the three ocean regions, the T-S gradient diagram is shown to be useful and acoustic field affected by low salinity environment is investigated in this study.

Analysis of the Image Processing Speed by Line-Memory Type (라인메모리 유형에 따른 이미지 처리 속도의 분석)

  • Si-Yeon Han;Semin Jung;Bongsoon Kang
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.494-500
    • /
    • 2023
  • Image processing is currently used in various fields. Among them, autonomous vehicles, medical image processing, and robot control require fast image processing response speeds. To fulfill this requirement, hardware design for real-time processing is being actively researched. In addition to the size of the input image, the hardware processing speed is affected by the size of the inactive video periods that separate lines and frames in the image. In this paper, we design three different scaler structures based on the type of line memories, which is closely related to the inactive video periods. The structures are designed in hardware using the Verilog standard language, and synthesized into logic circuits in a field programmable gate array environment using Xilinx Vivado 2023.1. The synthesized results are used for frame rate analysis while comparing standard image sizes that can be processed in real time.

ANALYTICAL TECHNIQUES FOR SYSTEM OF TIME FRACTIONAL NONLINEAR DIFFERENTIAL EQUATIONS

  • Choi, Junesang;Kumar, Devendra;Singh, Jagdev;Swroop, Ram
    • Journal of the Korean Mathematical Society
    • /
    • v.54 no.4
    • /
    • pp.1209-1229
    • /
    • 2017
  • We coupled the so-called Sumudu transform with the homotopy perturbation method (HPM) and the homotopy analysis method (HAM), which are called homotopy perturbation Sumudu transform method (HPSTM) and homotopy analysis Sumudu transform method (HASTM), respectively. Then we show how HPSTM and HASTM are more convenient than HPM and HAM by conducting a comparative analytical study for a system of time fractional nonlinear differential equations. A Maple package is also used to enhance the clarity of the involved numerical simulations.

Deformation Analysis of Semi-Solid Aluminum Material Considering Seperation Phenomena of Solid Particles (고상입자의 분리현상을 고려한 Semi-Solid 알루미늄재료의 변형해석)

  • 최진석;강충길;김기훈
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.98-105
    • /
    • 1997
  • The behaviour of alloys in the semi-solid state strongly depends on the imposed stress state and on the morphology of the phase which can very from dendritic to globular. The estimation of behaviour characteristic in the compression simulation with seim-solid materials are calculated by finite element method with proposed algorithm. The proposed theoretical model and a various boundary conditions for compression process is investigated with the coupling calculation between the liquid phase flow and the solid phase deformation. The simulation process considering soldification phenomena is performed to the isothermal conditions of two dimensional problems. To analysis of compression process by using semi-solid materials, a new stress-strain relationship is described, and compression analysis is performed by viscoelastic model for the solid phase and the Darcy's law for the liquid flow. The calculated results for compression force and ram displacement will be compared to experimental data.

  • PDF

Characteristics of Internal Hydrate Change in High Temperature Heated Concrete through Micro Analysis (미시 분석을 통한 고온 가열된 콘크리트의 내부 수화물 변화 특성)

  • Ji, Woo-Ram;Shin, Ki-Don;Cho, Hyeon-Seo;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.132-133
    • /
    • 2018
  • The In this study, the change of composition of the hydrates according to the recovery age of concrete in the case of fire damage was confirmed through microscopic analysis. In 28 days of age, the production of ettringite was higher than that of day 1, and the calcium hydroxide was increased in the 91 day. It has been recovered through the generation of major hydrates which affect the strength.

  • PDF

Analysis of the Changes of composition of Hardened Cement at High Temperature by X-Ray Diffraction (X-선 회절 분석을 통한 고온 피해 시멘트 경화체의 성분 변화 분석)

  • Ji, Woo-Ram;Park, Ji-Woong;Shin, Ki-Don;Lee, Gun-Cheol;Heo, Young-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.113-114
    • /
    • 2017
  • In this study, the change of composition of cement hardened at high temperature through XRD was observed. The specimen was made of cement paste and the heating rate condition was applied at rapid thermal annealing (10.0℃ / min). The decrease of calcium hydroxide was not confirmed, but the calcium carbonate tended to be impossible or decreased after 800℃. Calcium silicate and larnite were observed to increase with increasing temperature. It is considered that silicic acid, which is a stable structure due to the decomposition of calcium silicate, is changed into a phase such as lime.

  • PDF

Improving Data Input of ECO2-OD Program Utilizing BIM (BIM을 이용한 ECO2-OD 프로그램의 정보입력 개선)

  • Kang, Min-Su;Kim, Ka-Ram;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.205-207
    • /
    • 2013
  • In a situation that building energy consumption is increasing worldwide, the research utilizing BIM technology to analyze building energy has been actively conducted. On the other hand, data input method of the building energy analysis has been still manually entered. This paper proposed a improved input method of required information for building energy analysis using the ECO2-OD program. As a result, although some required information of BIM based design software could be almost entered when it comes to general information and architectural sector, it has a problem to be handled in HVAC sector. Therefore, in the both of general and architectural sectors, the BIM information from the BIM-based design software could be directly used to automatically and systematically input the information. Future research should be studied the algorism and method in connection with data exchange to utilize input method of ECO2-OD from BIM data.