• Title/Summary/Keyword: R&D Capacity

Search Result 885, Processing Time 0.028 seconds

Cycle Simulation of the Air-Conditioner Using Alternatives to R22 (R22의 대체냉매를 사용한 공기조화기의 성능 시뮬레이션)

  • Chang, S.D.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.47-53
    • /
    • 1994
  • Cycle simulation of the air-conditioner was carried out using a number of candidate alternatives to R22;R32/R125/R134a(30/10/60, by mass percent), R32/R125/R134a(10/70/20), R32/R134a(25/75), R32/R134a(30/70), R32/R125(60/40), R290(propane) and R134a. In this study, we considered only the basic parts of the air-conditioner such as the compressor, the evaporator, the condenser and the capillary tube, for the purpose of analysis. The performance characteristics of alternatives considered here were examined by comparing with the case using R22 at the constant volumetric flow rate condition. The results of our analysis revealed that the use of refrigerant mixtures, R32/R134a(30/70) and R32/R125/R134a(30/10/60), was appropriate for the alternatives to R22 in view of the cooling capacity and the COP. For the case of using R134a and R290, the COP was observed to increase under the same volumetric flow rate condition, but the cooling capacity was substantially decreased. Therefore the use of R134a and R290 should be accompanied with increasing considerably the size of compressor in order to maintain the same cooling capacity of R22.

  • PDF

Co-Evolution between Open Innovation and Absorptive Capacity in Korean SMEs (개방형 혁신과 흡수역량의 공진화 : 한국 중소기업의 혁신경로 관점)

  • Sohn, Dong-Won
    • Korean Management Science Review
    • /
    • v.29 no.3
    • /
    • pp.169-182
    • /
    • 2012
  • This study examines the co-evolutionary process between open innovation and firms' absorptive capacity. The effects of open innovation can be maximized through the capacity to absorb the knowledge from the external sources such as universities, government-support research institute, and private R&D centers. This study used data of STEPI technology innovation survey conducted at 2002, 2005, and 2008 (3 points measures). The data were analyzed through a structural equation model. Results suggest that open innovation at t0 point influences positively the absorptive capacity at t1 point, which subsequently enhances the intention of open innovation at t2 point. This result suggests the existence of co-evolutionary process between open innovation and firms' absorptive capacity. When knowledge comes from universities, the co-evolution has sustained; whereas when knowledge comes from private firms' R&D centers, the co-evolution has not effected. Theoretical and practical implications are discussed.

A Study on the Prediction of the Maximum Evaporation Rates from LPG Storage Tanks (소형저장탱크의 가스발생능력에 관한 연구)

  • Lee Kyung-Sik;Yu Kwang-Soo;Jo Young-Do;Park Kyo-Shik
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.1 s.30
    • /
    • pp.7-12
    • /
    • 2006
  • The quantity of gas which can be supplied by LPG storage tank become a standard of selection. In the absence of the maximum evaporation rates from LPG storage tanks by tank capacity, continuation using time, air temperature, it is in a problem for the dissemination of LPG Storage tanks. In this paper, we showed the maximum evaporation rates from LPG storage tanks by tank capacity, air temperature, continuous using time and remaining level.

  • PDF

Nursing Service R&D Strategy based on Policy Direction of Korean Government Supported Research and Development (국가보건의료 R&D 정책 방향에 따른 간호서비스 R&D 전략 연구)

  • Lee, Seonheui;Bae, Byoungjun
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.22 no.1
    • /
    • pp.67-79
    • /
    • 2016
  • Purpose: To develop strategies for research and development (R&D) in nursing service based on the policy direction of government supported R&D in Korea. Methods: This was a descriptive study to develop strategies for promoting R&D in nursing by analyzing investment trends and status quo, policy directions, and implementation of the details of government supported R&D through government reports, websites of relevant agencies and literature reviews. Results: Few nursing experts participated in clinical research on overcoming major diseases and in R&D for well-being and care. Development of nursing topics that meet the direction of government supported R&D were lacking. Insufficient implementation of nursing service R&D in a timely manner equipped with a performance-based system. Few research studies in R&D projects that included research using big data or contributing to developing medical instruments. Finally, an insufficient number of nursing specialists participated on government R&D advisory committees. Conclusion: For nursing service R&D development efforts should be toward quantitative expansion and qualitative improvements by sensitively recognizing policy direction of government supported R&D. The promotional capacity of nursing service R&D must be reinforced through a multidisciplinary approach and collaborative association with other professionals and the inclusion of nurse specialists on government R&D advisory committees.

Capacity esitmation of microcell in macro/microcell overlaid W-CDMA WLL system (매크로셀과 마이크로셀이 중첩된 W-CDMA 무선가입자망에서 마이크로셀의 용량 산정)

  • 손성찬;노재성;김수용;조성준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.9A
    • /
    • pp.2153-2164
    • /
    • 1998
  • This paper has presented the parameters for the coexistence between two systems in macro/microcell ovelaid W-CDMA WLL (wideband CDMA wireless local loop) and has calculated the capacity of forward/reverse link in microcell. To produce the capacity for analyzing system interference effects, we have shown tables and graphs with the parameters sucyh as RF channel bandwidth of WLL(W), the transmission rate of service message(R), the required signal power to noise power ratio( $E_{b/}$ $N_{0}$) for achieving accepatable error rate, te user number ( $N_{W1}$, $N_{W2}$) of the neighboring system, the signal power to interference power ratio(.GAMMA.$_{C1B}$, .GAMMA.$_{C2B}$) of the neighboring system, the normalized distance(d) between microcell and macrocell base-station, and microcell to macrocell radius ratio ( $R_{d}$). From the results, we have convinced that the capacity of microcell diminishes as increasing the user number ( $N_{W2}$) in macrocell, increasing the microcell radius, and decreasing the normalized distance(d) between microcell and macrocell base-station. Especially, we have known that when $R_{d}$=0.1, $N_{W2}$ must be below 24 at .GAMMA.$_{C2B}$ = 0 dB and below 8 at .GAMMA.$_{C2B}$ = 4 dB for the acceptable capacity raito to be over 80%. Therfore, this paper is usefult to design microcell W-CDMA WLL for accommodating more user number under the interference effects of macrocell W-CDMA WLL and is expected to be reference in power control if base-station.ation.ion.ation.ation.

  • PDF

The Performance Evaluation of R407C and R410B in a Residential Window Air-Conditioner

  • Kim, Man-Hoe;Shin, Jeong-Seob;Kim, Kwon-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.148-157
    • /
    • 1998
  • This study presents test results of a residential window air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests has been carried out for the basic and liquid-suction heat exchange cycles in a psychometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-suction heat exchange cycle was also considered to improve the system performance. Test results were compared with those for the basic R22 system. The modified system with a liquid-suction heat exchanger increased cooling capacity and energy efficiency by up to 5%.

  • PDF

COMPARISON OF THE BIOMECHANICAL AND BIOSYNTHETIC BEHAVIOR OF NORMAL HUMAN FIBROBLASTS AND FIBROBLASTS ISSUE FROM A FOREHEAD WRINKLE

  • Jouandeaud, M.;Viennet, C.;Chadebec, P.;Bordes, S.;Closs, B.;Humbert, P.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.192-202
    • /
    • 2003
  • The wrinkles correspond to the most obvious expression of skin ageing and are manifested by changes on the organization and dermal structure. In the extracellular matrix, decreased quantities of collagens and glycosaminoglycans as well as a deterioration of the fibrillary network is noted, result in a reduction of dermal thickness. In addition, the activity of the collagenases increases in contrast to the synthesis of collagen fibers. Nor are cells spared during the aging process. We thus studied and compared the contractile capacity as well as the synthesis capacity of normal human fibroblasts and human fibroblasts obtained from biopsies of forehead wrinkles. The capacity of the fibroblasts to be adhered to the collagen network and to maintain a three-dimensional structure of dermis was studied on a model of equivalent dermis. The metabolic activity was studied by evaluating the capacities of synthesis of collagen I, main component of dermis. Human fibroblasts resulting from the forehead wrinkle contract less the gel of collagen than the normal human fibroblasts and present an activity of biosynthesis of collagen I less important than normal human fibroblasts. These results show that fibroblasts with aging present a deceleration of their metabolic activity and lose their capacity of adhesion to collagen fibers thus limiting the possibility of organizing the dermal tissue. We investigated the potential of an active ingredient able to compensate for the reduction of the metabolic activity and to restore the contractile capacity of fibroblasts obtained from forehead wrinkles. This effect was compared with a reference molecule: the vitamin C.

  • PDF

A Study on the Applications of the ACM(Area Capacity Method) for the Carbon-Fiber Composit Cylinder according to the Flaw Depth (복합재 용기의 손상에 따른 ACM기법 적용 연구)

  • Jang, Kap Man;Yim, Sang Sik;Kim, Young Gyu;Kim, Jeong Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.5
    • /
    • pp.1-7
    • /
    • 2019
  • Although the rupture pressure is evaluated from remaining strength when a flaw is defected to cylinder surface, but the rupture pressure can be not easy to estimate for the composite cylinders. In this study, the area capacity method is developed for the type-3 cylinders that is based on the result applied area capacity method of type-1 cylinders. And the reliability is validated by bursting test with artificial flaw at the cylinder surface. The predicted data of area capacity method and experimental results have very similar tendency. This method and results will be a very important records in field of rupture pressure estimations.

Electrosorption of U(IV) by Electochemically Modified Activated Carbon Fibers

  • Jung, Chong-Hun;Oh, Won-Zin;Lee, Yu-Ri;Park, Soo-Jin
    • Carbon letters
    • /
    • v.6 no.1
    • /
    • pp.25-30
    • /
    • 2005
  • The electrosorption of U(VI) from waste water was carried out by using an activated carbon fiber (ACF) felt electrode in a continuous electrosorption cell. In order to enhance the electrosorption capacity at a lower potential, the ACF was electrochemically modified in an acidic and a basic solution. Pore structure and functional groups of the electrochemically modified ACF were examined, and the effects of the modification conditions were studied for the adsorption of U(VI). Specific surface area of all the ACFs was decreased by this modification. The amount of the acidic functional groups decreased with a basic modification, while the amount increased a lot with an acidic modification. The electrosorption capacity of U(VI) decreased on the acid modified electrode due to the shielding effect of the acidic functional groups. The base modified electrode enhanced the capacity due to a reduction of the acidic functional groups. The electrosorption amount of U(VI) on the base modified electrode at .0.3 V corresponds to that of the as-received ACF electrode at .0.9 V. Such a good adsorption capacity was due to a reduction of the shielding effect and an increase of the hydroxyl ions in the electric double layer on the ACF surface by the application of negative potential.

  • PDF

Study on the Performance Optimization of Commercial Metal Hydride Refrigerator Powered by Exhaust Gas from Micro Gas Turbine (마이크로가스터빈의 부하에 따른 상용 수소흡장냉동기의 성능 최적화에 관한 연구)

  • Kim Hyoungsik;Sohn Wha-seung;Choi Kyoung-shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.824-829
    • /
    • 2005
  • MHR(Metal Hydride Refrigerator) powered by MGT exhaust gas is investigated to find out the optimum conditions corresponding to MGT operating powers. There are many factors to affect cooling capacity of MHR. In this study, the effect of switching time, flow rate of brine on cooling temperature and capacity is investigated. The present results show (1) hydrogen reaction is saturated with 25 min switching time at 25 kW MGT power, (2) cooling power shows maximum phenomenon with increasing switching time, (3) optimum switching times are 20 minutes for 15kW MGT power and 15 minutes for 20, 25kW MGT power, (4) according to increasing brine flow rate, cooling capacity shows decrease at 15 kW MGT power and changes little at above 20 kW MGT power.