• 제목/요약/키워드: Quick test

검색결과 367건 처리시간 0.022초

Optimum time-censored ramp soak-stress ALT plan for the Burr type XII distribution

  • Srivastava, P.W.;Gupta, T.
    • International Journal of Reliability and Applications
    • /
    • 제15권2호
    • /
    • pp.125-150
    • /
    • 2014
  • Accelerated life tests (ALTs) are extensively used to determine the reliability of a product in a short period of time. Test units are subject to elevated stresses which yield quick failures. ALT can be carried out using constant-stress, step-stress, progressive-stress, cyclic-stress or random-stress loading and their various combinations. An ALT with linearly increasing stress is ramp-stress test. Much of the previous work on planning ALTs has focused on constant-stress, step-stress, ramp-stress schemes and their various combinations where the stress is generally increased. This paper presents an optimal design of ramp soak-stress ALT model which is based on the principle of Thermal cycling. Thermal cycling involves applying high and low temperatures repeatedly over time. The optimal plan consists in finding out relevant experimental variables, namely, stress rates and stress rate change points, by minimizing variance of reliability function with pre-specified mission time under normal operating conditions. The Burr type XII life distribution and time-censored data have been used for the purpose. Burr type XII life distribution has been found appropriate for accelerated life testing experiments. The method developed has been explained using a numerical example and sensitivity analysis carried out.

  • PDF

The Effects of Vibration Exercise after Modified Bröstrom Operation in Soccer Players with Ankle Instability

  • Kim, Sanghoon;Kim, Yangrae;Kim, Yongyoun
    • 국제물리치료학회지
    • /
    • 제10권2호
    • /
    • pp.1791-1796
    • /
    • 2019
  • Background: Vibration exercise after ankle surgery improves proprioception and ankle muscle strength through vibration stimulation. Objective: To examine the effects of vibration exercise on the ankle stability. Design: Randomized controlled clinical trial (single blind) Methods: Twenty soccer players were randomly divided into experimental group and control group. The Vibration exercise program was conducted 12 weeks and 3 times a week. Ankle joint proprioceptive sensory test and Isokinetic muscle strength test were performed using Biodex system pro III to measure plantar flexion / dorsiflexion and eversion / inversion motion. Results: The result of isokinetic test of ankle joint is showed significant improvement in all measurement items, such as leg flexion, lateral flexion, external and internal muscle forces, compared to previous ones by performing vibration movements for 12 weeks. However, in the comparison group, plantar flexor ($30^{\circ}$), eversion muscle ($120^{\circ}$), inversion ($30^{\circ}$) of limb muscle strength were significantly improved compared with the previous phase; was no significant difference in dorsi-flexion. There was no significant difference between groups in all the items. Conclusions: In this study, we analyzed the effects of rehabilitation exercise on soccer players who had reconstructed with an ankle joint ligament injury through vibration exercise device. As a result, we could propose an effective exercise method to improve the ability, and confirmed the applicability as an appropriate exercise program to prevent ankle injuries and help quick return.

A Short Test of English Silent Word Reading for English Language Learners

  • Kalindi, Sylvia C.;McBride, Catherine;Chan, Shingfong;Chung, Kien Hoa Kevin;Lee, Chia-Ying;Maurer, Urs;Tong, Xiuhong
    • Child Studies in Asia-Pacific Contexts
    • /
    • 제5권2호
    • /
    • pp.95-105
    • /
    • 2015
  • We developed a test of English silent word reading, following work by Mather, Hammill, Allen and Roberts (2004) and Bell, McCallum, Krik, Fuller, and McCane-Bowling (2007), in order to tap Hong Kong Chinese children's reading of English as a foreign language. We created one subtest of individual word reading and another of word reading contextualized within sentences; together, these tests require no more than 10 minutes for administration. In Study 1, we administered the entire test to 552 second grade Hong Kong Chinese children between the ages of 70 and 121 months old, from five different primary schools. The association between the subtests of English silent word reading and contextual reading was positively correlated (.78). In Study 2, 77 Hong Kong Chinese second graders were tested on our newly developed English silent word reading test, together with non-verbal IQ, an English word reading and a Chinese character recognition test (both read aloud). With age and non-verbal IQ statistically controlled, there was a significant correlation between English silent word reading and the more standard English word reading, read aloud, (.78); the association between English silent word reading and Chinese character recognition was also positively correlated (.49). This newly created test is a quick and reliable measure, suitable for both educators and researchers to use to identify poor readers who learn English as a foreign or second language.

Measurement of Ordinary Heterotrophic Organism Active Biomass in Activated Sludge Mixed Liquor: Evaluation and Comparison of the Quantifying Techniques

  • Lee, Byung Joon;Wentzel, Mark;Ekama, George;Choi, Yun Young;Choi, Jung Woo
    • Environmental Engineering Research
    • /
    • 제19권1호
    • /
    • pp.91-99
    • /
    • 2014
  • Ordinary heterotrophic organism (OHO) active biomass plays key roles in biological wastewater treatment processes. However, due to the lack of measurement techniques, the OHO active biomass exists hypothetically within the design and simulation of biological wastewater treatment processes. This research was purposed to develop a quick and easy quantifying technique for the OHO active biomass applying a modified batch aerobic growth test. Two nitrification-denitrification activated sludge systems, with 10- and 20-day sludge ages, were operated to provide well-cultured mixed liquor to the batch tests. A steady state design model was firstly applied to quantify the "theoretical" OHO active biomass concentration of the two parent systems. The mixed liquor from the parent systems was then inoculated to a batch growth test and a batch digestion test to estimate the "measured" OHO active biomass concentration in the mixed liquor. The measured OHO active biomass concentrations with the batch growth test and the batch digestion test were compared to the theoretical concentrations of the parent system. The measured concentrations with the batch growth test were generally smaller than the theoretical concentrations. However, the measured concentrations with the batch aerobic digestion tests showed a good correlation to the theoretical concentrations. Thus, a different microbial growth condition (i.e., a higher food/biomass ratio) in the batch growth test, compared to the parent system or the batch digestion test, was found to cause underestimation of the OHO active biomass concentrations.

속경성 바인더 유형에 따른 긴급보수용 스프레이 패칭 상온 재활용 아스팔트 혼합물(RAP)의 성능 평가 (Performance Evaluation of 100 % RAP Asphalt Mixtures using different types of Rapid-Setting Polymer-Modified Asphalt Emulsion for Spray Injection Application)

  • 김두열;전지성;이상염;이석근;권봉주
    • 한국도로학회논문집
    • /
    • 제19권2호
    • /
    • pp.75-85
    • /
    • 2017
  • PURPOSES : The purpose of this study was to determine the optimum mix design of the content of 100 % reclaimed asphalt pavement (RAP) for spray injection application with different binder types. METHODS : Literature review revealed that spray injection method is the one of the efficient and economical methods for repairing a small defective area on an asphalt pavement. The Rapid-Setting Polymer modified asphalt mixtures using two types of rapid setting polymers-asphalt emulsion and a quick setting polymer asphalt emulsion-were subjected to the following tests to determine optimum mix designs and for performance comparison: 1) Marshall stability test, 2) Retained stability test, 3) Wet track abrasion test, and 4) Dynamic stability test. RESULTS and CONCLUSIONS : Type A, B, and C emulsions were tested with different mix designs using RAP aggregates, to compare the performances and determine the optimum mix design. Performance of mixtures with Type A emulsion exceeded that of mixtures with Type B and C emulsion in all aspects. In particular, Type A binder demonstrated the highest performance for WTAT at low temperature. It demonstrated the practicality of using Type A mixture during the cold season. Furthers studies are to be performed to verify the optimum mix design for machine application. Differences in optimum mix designs for machine application and lab application will be corrected through field tests.

표면반발경도와 초음파 속도를 활용한 고강도 콘크리트 압축강도 추정 (Estimating the Compressive Strength of High-Strength Concrete Using Surface Rebound Value and Ultrasonic Velocity)

  • 김민욱;오홍섭;오광진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권2호
    • /
    • pp.1-9
    • /
    • 2016
  • 저자들은 비파괴시험에 의한 고강도콘크리트의 강도 예측식을 제안하기 위하여 실험적 연구를 수행하였다. 본 연구에서 사용된 콘크리트의 설계압축강도는 40~80 MPa 범위이며, 압축공시체를 제작하여 반발경도법과 초음파 속도법으로 실험한후 KS기준에 따라 압축강도 실험을 실시하였다. 실험결과는 기존의 연구자들에 의하여 제안된 다양한 실험예측식들과 비교분석하였다. 실험결과 고강도 콘크리트에서도 반발경도법과 초음파속도법의 경우 간편성과 신뢰성에 있어 콘크리트 강도를 측정하기에 충분한 유용성을 확보한 것을 확인할 수 있었다. 기존식들과의 비교를 통하여 고강도 콘크리트에 적합한 강도예측식을 제안하였으며, 실험결과에 대한 충분한 신뢰성을 확보한 것으로 판단되어, 향후 고강도 콘크리트 구조물에 적용할 수 있을 것으로 판단된다.

Environmental test campaign of a 6U CubeSat Test Platform equipped with an ambipolar plasma thruster

  • Stesina, Fabrizio;Corpino, Sabrina;Borras, Eduard Bosch;Amo, Jose Gonzalez Del;Pavarin, Daniele;Bellomo, Nicolas;Trezzolani, Fabio
    • Advances in aircraft and spacecraft science
    • /
    • 제9권3호
    • /
    • pp.195-215
    • /
    • 2022
  • The increasing interest in CubeSat platforms ant their capability of enlarging the frontier of possible missions impose technology improvements. Miniaturized electrical propulsion (EP) systems enable new mission for multi-unit CubeSats (6U+). While electric propulsion systems have achieved important level of knowledge at equipment level, the investigation of the mutual impact between EP system and CubeSat technology at system level can provide a decisive improvement for both the technologies. The interaction between CubeSat and EP system should be assessed in terms of electromagnetic emissions (both radiated and conducted), thermal gradients, high electrical power management, surface chemical deposition, and quick and reliable data exchanges. This paper shows how a versatile CubeSat Test Platform (CTP), together with standardized procedures and specialized facilities enable the acquisition fundamental and unprecedented information. Measurements can be taken both by specific ground support equipment placed inside the vacuum facility and by dedicated sensors and subsystems installed on the CTP, providing a completely new set of data never obtained before. CTP is constituted of a 6U primary structure hosting the EP system, representative CubeSat avionics and batteries. For the first test campaign, CTP hosts the ambipolar plasma propulsion system, called Regulus and developed by T4I. After the integration and the functional test in laboratory environment, CTP + Regulus performed a Test campaign in relevant environment in the vacuum chamber at CISAS, University of Padua. This paper is focused on the test campaign description and the main results achieved at different power levels for different duration of the firings.

앉았다 일어서기 검사 종류와 신체 근육량의 상관관계 연구 (Types of Sit-to-Stand Tests and Research on the Correlation with Body Muscle Mass)

  • 박태성;이소정;신명준;강종호
    • PNF and Movement
    • /
    • 제21권2호
    • /
    • pp.223-229
    • /
    • 2023
  • Purpose: Assessing physical strength and muscle mass is crucial, but many methods rely on specialized equipment, which can be challenging. In situations where a quick and straightforward test is needed, the sit-to-stand test (STST) proves useful. Although several studies have investigated STST and muscle mass separately, the actual correlation between these two factors has not been extensively researched. Hence, the objective was to comprehensively investigate the correlations between the different tests. Methods: The study participants consisted of 20 healthy young men in their 20s. In this study, measurements were taken for muscle mass, the five-times sit-to-stand test, the 30-second sit-to-stand test, and the 1-minute sit-to-stand test. The results of each test were analyzed using Pearson's correlation analysis. Results: Although no significant correlation was found between muscle mass and STST, interestingly, significant correlations were observed among the different types of STST. Conclusion: The STST is a rapid and straightforward test used to assess lower limb strength and balance ability in individuals. However, there is a dearth of research on STST conducted in domestic settings. Based on the findings of this study, further research is necessary to establish age- and gender-specific reference values for STST. This will allow its broader application, encompassing not only older adults and patients but also healthy individuals.

상호검증시험을 통한 효율적인 다운홀 탄성파 기법 수행 시스템의 구성 (Construction of Efficient Downhole Seismic Testing System by the Round Robin Test)

  • 방은석;김기석;김동수
    • 한국지반공학회논문집
    • /
    • 제23권4호
    • /
    • pp.133-147
    • /
    • 2007
  • 지반의 전단파 속도 주상도를 도출하는데 있어 다운홀 기법은 하나의 시추공을 이용하고 간단한 지표면 가진원을 사용하므로 매우 경제적이다. 따라서 학교와 현업에서 지반조사 및 연구 목적으로 널리 사용되고 있다. 그러나 올바르지 못한 장비의 구성과 해석과정으로 인하여 결과의 신뢰성에 문제가 있어왔다. 본 연구에서는 다운홀 기법의 상호검증시험(Round Robin Test)을 통해 참여 기관에 대해서 각각의 실험 장비와 결과 해석 과정에 대해 비교함으로써 문제점에 대해 분석하였으며 이를 바탕으로 최적의 수행 시스템을 구성하였다. 효율적인 가진원을 제작하고 적절한 감지기를 도입 혹은 제작하였으며 노트북 기반의 신호 획득 시스템을 구축하였다. 신호 획득 및 관리 프로그램, 결과도출 프로그램을 통해 현장에서 효율적으로 실험을 진행하고 신뢰성 있는 최종 결과를 신속하게 도출할 수 있도록 하였다. 구성된 수행 시스템을 이용하여 현장 적용 실험을 수행하였으며 그 효율성을 확인할 수 있었다.

Clinical evaluation of efficacy of transcortical anesthesia for the extraction of impacted mandibular third molars: a randomized controlled trial

  • Demir, Esin;Ataoglu, Hanife
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권1호
    • /
    • pp.9-17
    • /
    • 2020
  • Background: This study aimed to compare the pain levels during anesthesia and the efficacy of the QuickSleeper intraosseous (IO) injection system and conventional inferior alveolar nerve block (IANB) in impacted mandibular third molar surgery. Methods: This prospective randomized clinical trial included 30 patients (16 women, 14 men) with bilateral symmetrical impacted mandibular third molars. Thirty subjects randomly received either the IO injection or conventional IANB at two successive appointments. A split-mouth design was used in which each patient underwent treatment of a tooth with one of the techniques and treatment of the homologous contralateral tooth with the other technique. The subjects received 1.8 mL of 2% articaine. Subjects' demographic data, pain levels during anesthesia induction, tooth extractions, and mouth opening on postoperative first, third, and seventh days were recorded. Pain assessment ratings were recorded using the 100-mm visual analog scale. The latency and duration of the anesthetic effect, complications, and operation duration were also analyzed in this study. The duration of anesthetic effect was considered using an electric pulp test and by probing the soft tissue with an explorer. Results: Thirty patients aged between 18 and 47 years (mean age, 25 years) were included in this study. The IO injection was significantly less painful with lesser soft tissue numbness and quicker onset of anesthesia and lingual mucosa anesthesia with single needle penetration than conventional IANB. Moreover, 19 out of 30 patients (63%) preferred transcortical anesthesia. Mouth opening on postoperative first day was significantly better with intraosseous injection than with conventional IANB (P = 0.013). Conclusion: The IO anesthetic system is a good alternative to IANB for extraction of the third molar with less pain during anesthesia induction and sufficient depth of anesthesia for the surgical procedure.