• Title/Summary/Keyword: Quantitative parameters

Search Result 1,116, Processing Time 0.026 seconds

An Analysis of Relationship between Self-Reported Anxiety, Depressiveness and Parametors of Heart rate variability based on Photoplethysmography (불안 및 우울에 대한 주관적 설문평가 지표와 맥파 신호 기반의 심박변이도 요소들 간의 상관관계 분석)

  • Lee, Chung-Ki;Yoo, Sun-Kook
    • Science of Emotion and Sensibility
    • /
    • v.15 no.3
    • /
    • pp.345-354
    • /
    • 2012
  • The purpose of this study is finding alternative parameters of the HRV so as to minimize the subjective errors by STAI and BDI, could be have two types of significant correlation levels depending on normalized method. Particularly, the LF/HF presented as the quantitative physiological parameter that can reflect both state-anxiety and trait-anxiety.

  • PDF

Analysis of Arterial Stiffness Variation by Photoplethysmographic DC Component (광용적맥파 비맥동성분에 의한 혈관경직도 변화 분석)

  • Lee, Chung-Keun;Shin, Hang-Sik;Kong, In-Deok;Lee, Myoun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.109-117
    • /
    • 2011
  • Assuming that photons absorbed by a vessel do not have acute variations, DC component reflect the basal blood volume (or diameter) before blood pulsation. Vascular stiffness and reflection is influenced by changes in basal blood volume (or diameter). This paper describes analysis of the characteristic variations of vascular stiffness, according to relative variations in DC components of the PPG signal (25-75%). For quantitative analysis, we have used parameters that were proposed previously, reflection and stiffness index, and the second derivative of PPG waveform, b/a and d/a. Significantly, the vascular stiffness and reflections were increased according to increase in DC component of the PPG signal for more than about 3% of baseline values. The systolic blood pressure were increased from $113.1{\times}13.18$ to $116.2{\times}13.319$ mmHg, about 2.76% (r = 0.991, P < 0.001) and the AC component of the PPG signal were decreased from $2.073{\times}2.287$ to $1.973{\times}2.2038$ arbitrary unit, about 5.09% (r = -0.993, P < 0.001). It is separated by DC median and correlation analysis was performed for analyzing vascular characteristics according to instantaneous DC variations. There are significant differences between two correlation coefficients in separated data.

Development of a Simultaneous CAE System for the Application to Large Steel Castings (대형주강품에 대한 CAE 시스템 개발 연구)

  • Lee, Young-Chul;Lee, Doo-Ho;Kim, Jong-Ki;So, Chan-Young;Choi, Jeong-Kil;Hong, Chun-Pyo
    • Journal of Korea Foundry Society
    • /
    • v.17 no.5
    • /
    • pp.465-471
    • /
    • 1997
  • An integrated computer program consisting of a pre-processor, main solver, and post-processor was developed for the design of large steel castings. The pre-processor, based on the AutoCAD, enables the user to produce approval drawings, casting design drawings and mesh diagrams in sequence using a personal computer. In the main solver, two numerical models were employed; one models the fluid flow during mold filling, and the other models the heat transfer and solidification. The post-processor can be used to present simulation results such as flow pattern, mold filling sequences, solidification times, temperature gradients and location of shrinkage defects by color graphics. In order to validate the applicability of the present integrated program, a series of experiments on simple-shaped steel castings were carried out. After the validation of the present model, it was applied to the casting design of the large steel anchor of an SC42 alloy. Various solidification parameters such as a temperature distribution and a solidification time in the casting and the mold were compared with those obtained experimentally. Simulated results predicting shrinkage defects were in good agreement with those obtained experimentally. It was found that the present method can be successfully applied to the quantitative casting design for complex-shaped large steel castings.

  • PDF

A Design and Implementation of a Timing Analysis Simulator for a Design Space Exploration on a Hybrid Embedded System (Hybrid 내장형 시스템의 설계공간탐색을 위한 시간분석 시뮬레이터의 설계 및 구현)

  • Ahn, Seong-Yong;Shim, Jea-Hong;Lee, Jeong-A
    • The KIPS Transactions:PartA
    • /
    • v.9A no.4
    • /
    • pp.459-466
    • /
    • 2002
  • Modern embedded system employs a hybrid architecture which contains a general micro processor and reconfigurable devices such as FPGAS to retain flexibility and to meet timing constraints. It is a hard and important problem for embedded system designers to explore and find a right system configuration, which is known as design space exploration (DSE). With DES, it is possible to predict a final system configuration during the design phase before physical implementation. In this paper, we implement a timing analysis simulator for a DSE on a hybrid embedded system. The simulator, integrating exiting timing analysis tools for hardware and software, is designed by extending Y-chart approach, which allows quantitative performance analysis by varying design parameters. This timing analysis simulator is expected to reduce design time and costs and be used as a core module of a DSE for a hybrid embedded system.

Design of Sound Quality Index for Laser Printers and Its Application for Improvement Study (프린터의 음질 인덱스 제작과 음질개선에 대한 응용)

  • Kim, Eui-Youl;Lee, Young-Jun;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.6
    • /
    • pp.509-523
    • /
    • 2012
  • The sound quality based on design optimization, throughout the development process of various electronic office equipments, needs to be considered in order to respond the increased needs for the emotional satisfaction of customers in terms of psycho-acoustics. This paper focuses on how to describe the characteristics of operating sound radiated from laser printers by using various sound attributes, and to model the sound quality index that can properly evaluate the subjective preference on modification conditions in the improvement study quantitatively. Especially, the proposed verification process, in the form of combining the correlation based method and the decision error based method, was applied to improve the generality and reliability of a group of participants in the jury evaluation. The modified Aures tonality model was also proposed to improve the correlation coefficient with the mean response of participants by optimizing some parameters. As a result, the loudness, articulation index, roughness, tonality, fluctuation strength were used to model the sound quality index for laser printers by using the multiple-linear regression method. Through the improvement study, it was confirmed that replacing the absorbing materials is effective to reduce the tonalness radiated from the side of a reference printer model. Based on above results, it can be concluded that the proposed model has enough usefulness as quantitative evaluation index to evaluate the difference between modification conditions in the improvement study.

Reliability of Modified Ashworth Scale Using a Haptic Robot Finger Simulating Finger Spasticity (손가락 경직을 모사하는 로봇 시뮬레이터를 이용한 경직도 검진의 신뢰도 평가)

  • Ha, Dokyeong;Park, Hyung-Soon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.2
    • /
    • pp.125-133
    • /
    • 2017
  • This paper presents the inter-rater reliability of finger spasticity assessment tested realized by using finger simulator that mimics finger spasticity of patients after a stroke. For controlling the simulator torque, finger spasticity was modeled, and the model parameters were obtained by measuring quantitative data while grading based on Modified Ashworth Scale (MAS). A robotic finger simulator was designed for mimicking finger spasticity. Evaluation of this simulator with the help of seven rehabilitation doctors showed that the simulator had a Cohen's kappa value of 0.619 for Metacarpophalangeal Joint and 0.514 for Proximal Interphalangeal Joint. Fleiss' kappa between raters is 0.513 for Metacarpophalangeal Joint and 0.486 for Proximal Interphalangeal Joint. Therefore, the spasticity assessment made by MAS grade system is not reliable owing to the subjectivity of the assessment. The proposed robotic simulator can be used as a training tool for improving the reliability of the spasticity assessment.

A Study on the Factors Influencing on the Intention to Continuously Use a Smart Factory (스마트 팩토리 지속사용의도에 영향을 미치는 요인에 관한 연구)

  • Kim, Hyun-gyu
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.2
    • /
    • pp.73-85
    • /
    • 2020
  • While Korea became one of manufacturing powers in the world through a fast-follower strategy as well as implementing the approach of advancing manufacturing business focused on quantitative input, The advent of the fourth industrial revolution and demand becoming more complicated than ever both require a system that quickly detects the change of markets in advance and reflects it in the manufacturing strategy. Accordingly, the introduction of a smart factory is not optional but mandatory in order to strengthen the competitiveness of manufacturing business using ICT. This paper aims to investigate key factors having influence on the intention to continuously use a smart factory, the innovative IT device, on the basis of the technology acceptance model. This paper analyzed the influence of the leadership of CEO, organizational learning and perceived switching costs on the intention to continuously use a smart factory by the parameters of perceived ease of use and usefulness, the major belief valuables of the IT acceptance model.

An Analysis on Performance Degradation of Silicon Photomultipliers over Temperatures Variation for PET-MR Application (PET-MR 시스템에 적용을 위한 실리콘 광증배센서의 온도 변화에 따른 성능 열화 분석)

  • Park, Kyeongjin;Kim, Hyoungtaek;Lim, Kyungtaek;Cho, Minsik;Kim, Giyoon;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.143-151
    • /
    • 2015
  • A PET-MR system is particularly useful in diagnosing brain diseases. We have developed a prototype positron emission tomography (PET) system which can be inserted into the bore of a whole-body magnetic resonance imaging (MRI) system that enables us to obtain PET and MRI images simultaneously with a reduced cost. Silicon photomultipliers (SiPM) are appropriated as a PET detector at PET/MR system because detectors have a high gain and are insensitive to magnetic fields. Despite of its improved performance compared to that of PMT-based detectors, there is a problem of the photo-peak channel shift which is due to the increase of the temperature inside the ring detector. This problem will occur decreasing sensitivity of the PET and image distortion. In this paper, I quantitative analyze parameters of the KAIST SiPM depending on temperature by experiments. And I designed cooling methods in consideration of the degradation of sensors for correction of the temperature in the PET gantry. According to this research, we expect that distortive images and degradation of the sensitivity will not be occurred with using the above idea to reduce heat even if the PET system operates for a long time.

Calibration of APEX-Paddy Model using Experimental Field Data

  • Mohammad, Kamruzzaman;Hwang, Syewoon;Cho, Jaepil;Choi, Soon-Kun;Park, Chanwoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.155-155
    • /
    • 2019
  • The Agricultural Policy/Environmental eXtender (APEX) models have been developed for assessing agricultural management efforts and their effects on soil and water at the field scale as well as more complex multi-subarea landscapes, whole farms, and watersheds. National Academy of Agricultural Sciences, Wanju, Korea, has modified a key component of APEX application, named APEX-Paddy for simulating water quality with considering appropriate paddy management practices, such as puddling and flood irrigation management. Calibration and validation are an anticipated step before any model application. Simple techniques are essential to assess whether or not a parameter should be adjusted for calibration. However, very few study has been done to evaluate the ability of APEX-Paddy to simulate the impact of multiple management scenarios on nutrients loss. In this study, the observation data from experimental fields at Iksan in South Kora was used in calibration and evaluation process during 2013-2015. The APEX auto- calibration tool (APEX-CUTE) was used for model calibration and sensitivity analysis. Four quantitative statistics, the coefficient of determination ($R^2$),Nash-Sutcliffe(NSE),percentbias(PBIAS)androotmeansquareerror(RMSE)were used in model evaluation. In this study, the hydrological process of the modified model, APEX-Paddy, is being calibrated and tested in predicting runoff discharge rate and nutrient yield. Field-scale calibration and validation processes are described with an emphasis on essential calibration parameters and direction regarding logical sequences of calibration steps. This study helps to understand the calibration and validation way is further provided for applications of APEX-Paddy at the field scales.

  • PDF

Carcass characteristics of lambs fed diets with increasing levels of crude glycerin

  • Costa, Caio Alves da;Carvalho, Francisco Fernando Ramos de;Guim, Adriana;Andrade, Gilcifran Prestes de;Cardoso, Daniel Barros;Maciel, Michel do Vale;Silva, Gabriela Goncalves da;Nascimento, Andreza Guedes de Oliveira
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.12
    • /
    • pp.1882-1888
    • /
    • 2019
  • Objective: An experiment was conducted to evaluate the effects of increasing levels of crude glycerin (0%, 6%, 12%, and 18%) used as a substitute for corn in lamb feed on the quantitative characteristics of the carcass. Methods: A total of 40 crossbred Santa $In{\hat{e}}s$ lambs that were four months old with a mean initial weight of $21.0{\pm}0.8kg$ were randomly distributed in four treatments with ten replicates. The animals were slaughtered after 66 days of confinement. The effects of crude glycerin as a replacement for corn in the diet of the lambs on the carcass characteristics, commercial cut weight and yield and carcass measurements were studied. Results: There was an increasing linear effect for body weight at slaughter with the replacement of corn by crude glycerin. The dry matter and metabolizable energy intakes, weight of the empty body, hot carcass weight and cold carcass weight showed a quadratic effect, with maximum crude glycerin levels estimated at 10.9%, 9.8%, 10.83%, 11.78%, and 11.35%, respectively. The initial pH was not influenced by the replacement of corn for crude glycerin, while the final pH presented a quadratic effect. The other parameters of the carcass and the weights and yields of commercial cuts were not influenced. There was also no effect of the diets on carcass morphometric measurements, except for the thoracic perimeter and the carcass compactness index, which presented quadratic and linear effects, respectively. Conclusion: Crude glycerin can replace up to 18% of corn because it favours muscle tissue deposition without promoting changes in the main carcass characteristics of lambs.