DOI QR코드

DOI QR Code

Reliability of Modified Ashworth Scale Using a Haptic Robot Finger Simulating Finger Spasticity

손가락 경직을 모사하는 로봇 시뮬레이터를 이용한 경직도 검진의 신뢰도 평가

  • Ha, Dokyeong (Dept. of Aerospace and Mechanical Engineering, Korea Advanced Institute of Technology) ;
  • Park, Hyung-Soon (Dept. of Aerospace and Mechanical Engineering, Korea Advanced Institute of Technology)
  • 하도경 (한국과학기술원 기계항공시스템학부) ;
  • 박형순 (한국과학기술원 기계항공시스템학부)
  • Received : 2016.07.18
  • Accepted : 2016.11.11
  • Published : 2017.02.01

Abstract

This paper presents the inter-rater reliability of finger spasticity assessment tested realized by using finger simulator that mimics finger spasticity of patients after a stroke. For controlling the simulator torque, finger spasticity was modeled, and the model parameters were obtained by measuring quantitative data while grading based on Modified Ashworth Scale (MAS). A robotic finger simulator was designed for mimicking finger spasticity. Evaluation of this simulator with the help of seven rehabilitation doctors showed that the simulator had a Cohen's kappa value of 0.619 for Metacarpophalangeal Joint and 0.514 for Proximal Interphalangeal Joint. Fleiss' kappa between raters is 0.513 for Metacarpophalangeal Joint and 0.486 for Proximal Interphalangeal Joint. Therefore, the spasticity assessment made by MAS grade system is not reliable owing to the subjectivity of the assessment. The proposed robotic simulator can be used as a training tool for improving the reliability of the spasticity assessment.

본 연구에서는 환자의 손가락 경직을 모사하는 손가락 시뮬레이터를 통해 손가락 경직도 검진에서의 검진자간 신뢰도에 대해 연구하였다. 시뮬레이터를 제어하기 위해 경직에서 나타나는 토크를 간단하게 모델링 하고 손가락 경직 환자로부터 간단한 측정 모듈을 이용해 각각의 Modified Ashworth Scale(MAS) 등급에 맞는 파라미터를 얻어냈다. 또한 중수지 관절에 모터가 위치한 손가락 형태의 로봇을 설계하여 경직 토크 모델을 따르는 시뮬레이터를 개발하였다. 이 시뮬레이터를 통해 일곱 명의 재활의학과 전문의들의 검진 결과를 평가해본 결과 중수지 관절에서 0.619, 근위지간 관절에서 0.514의 Cohen's Kappa 값을 보였다. 검진자간의 Fleiss' Kappa 값은 중수지 관절에서 0.513, 근위지간 관절에서 0.486으로 나타났다. 또한 검진자들은 각각의 주관적인 MAS 검진 기준을 가진다는 것을 확인하였다. 결과적으로 같은 환자에 대한 MAS 검진 신뢰도가 높지 않기 때문에 개발된 로봇 시뮬레이터는 검진자의 신뢰도를 높일 수 있는 교육용 도구로서 활용 가능함을 확인하였다.

Keywords

References

  1. Mozaffarian, D., Benjamin, E.J., Go, A.S., Amett, D.K, Blaha, M.J., Cushman, M., de Ferranti, S., Despres, J.P., Fullerton, H.J., Howard, V.J., Huffman, M.D., Judd, S.E., Kissela, B.M, Lackland, D.T., Lichtman, J.H, Lisabeth, L.D., Liu, S., Mackey, R.H., Matchar, D.B., McGuire, D.K., Mohler III, E. R., Moy, C.S., Muntner, P., Mussolino, M.E., Nasir, K., Neumar, R.W., Nichol, G., Palaniappan, L., Pandey, D.K., Reeves, M.J., Rodriguez, C.J., Sorlie, P.D., Stein, J., Towfighi, A., Turan, T.N., Virani, S.S., Willey, J.Z., Woo, D., Yeh, R.W. and Turner, M.B., 2015, "Heart Disease and Stroke Statistics-2015 Update: a Report from the American Heart Association," Circulation, Vol. 131, No. 4, e29-322. https://doi.org/10.1161/CIR.0000000000000152
  2. The National SCI Statistical Center., 1999, "Facts and Figures at a Glance," Birmingham: University of Alabama.
  3. Trombly, C.A., 1989, "Occupational Therapy for Physical Dysfunction," Lippincott Williams & Wilkins, Baltimore, pp. 454-471.
  4. Lance, W.W., 1980, "The Control of Muscle Tone, Reflexes and Movement: Robetd Wartenberg Lecture," Neurology, Vol. 30, pp. 1303-1313. https://doi.org/10.1212/WNL.30.12.1303
  5. Ashworth, B., 1964, "Preliminary Trial of Carisoprodol in Multiple Sclerosis," Practitioner, Vol. 192, pp. 540-542.
  6. Bohannon, R.W. and Smith, M.B., 1987, "Interrater Reliability of a Modified Ashworth Scale of Muscle Spasticity," Physical Therapy, Vol. 67, No. 2, pp. 206-207. https://doi.org/10.1093/ptj/67.2.206
  7. Gracies, J.M., Marosszeky, J.E., Renton, R., Sandanam, J., Gandevia, S.C. and Burke, D., 2000, "Short-term Effects of Dynamic Lycra Splints on Upper Limb in Hemiplegic Patients" Arch Phys Med Rehabil, Vol. 81, No. 12, pp. 1547-55. https://doi.org/10.1053/apmr.2000.16346
  8. Cohen, J., 1960, "A Coefficient of Agreement for Nominal Scales," Educational and Psychological Measurement, Vol. 20, No. 1, pp. 37-46. https://doi.org/10.1177/001316446002000104
  9. Mehrholz, J., Wagner, K., Meissner, D., Grundmann, K., Zange, C., Koch, R. and Pohl, M., 2005, "Reliability of the Modified Tardieu Scale and the Modified Ashworth Scale in Adult Patients with Severe Brain Injury: a Comparison Study," Clin Rehabil, Vol. 19, No. 7, pp. 751-759. https://doi.org/10.1191/0269215505cr889oa
  10. Park, H.S., Kim, J. and Damiao, D.L., 2012, "Development of a Haptic Elbow Spasticity Simulator (HESS) for Improving Accuracy and Reliability of Clinical Assessment of Spasticity," IEEE Trans. Neural Syst Rehabil Eng., Vol. 20, No. 3, pp. 361-370. https://doi.org/10.1109/TNSRE.2012.2195330
  11. Zhang, L. Q., Huang, H., Sliwa, J. A. and Rymer, W. Z., 1999, "System Identification of Tendon Reflex Dynamics," IEEE Trans. Rehabil. Eng., Vol. 7, No. 2, pp. 193-203. https://doi.org/10.1109/86.769410
  12. Hill, A.V., 1938, "The Heat of Shortening and Dynamics Constants of Muscles," Proc. R. Soc. London. B, Vol. 126, No. 843, pp. 136-195. https://doi.org/10.1098/rspb.1938.0050
  13. Patrick, H. M., Janice, J. E. and Antony, J. H., 2003, "Linear Spring-damper Model of the Hypertonic Elbow: Reliability and Validity," Journal of Neuroscience Methods, Vol. 128, No. 1-2, pp. 121-128. https://doi.org/10.1016/S0165-0270(03)00169-9
  14. Devin, L.J., Aruna, D. B. and Jack, T. D., 2004, "Finger Joint Impedance during Tapping on a Computer Keyswitch," Journal of Biomechanics, Vol. 37, No. 10, pp. 1589-1596. https://doi.org/10.1016/j.jbiomech.2004.01.001
  15. Calota, A., Feldman, A.G. and Levin, M.F., 2008, "Spasticity Measurement Based on Tonic Stretch Reflex Threshold in Stroke Using a Portable Device," Clin. Neurophysiol, Vol. 119, no. 10, pp. 2329-2337. https://doi.org/10.1016/j.clinph.2008.07.215
  16. Lance, W.W., 1980, "The Control of Muscle Tone, Reflexes and Movement: Robert Wartenberg Lecture," Neurology, Vol. 30, No. 12, pp. 1303-13. https://doi.org/10.1212/WNL.30.12.1303
  17. Jeong, H.-S. and Jeong, H.-S., 2003, "Descriptive Survey on the Dimensions and the Characteristics of Korean Hands in General," Journal of the Ergonomics Society of Korea, Vol. 22, No. 2, pp. 29-44. https://doi.org/10.5143/JESK.2003.22.2.029
  18. Lee, J. and Kunii, T., 1995, "Model-based Analysis of Hand Posture," IEEE Computer Graphics and Applications, Vol. 15, No. 5, pp. 77-86. https://doi.org/10.1109/38.403831
  19. McHugh, M.L., 2012, "Interrater Reliability: the Kappa Statistic," Biochem Med (Zagreb), Vol. 22, No. 3, pp. 276-282.
  20. Fleiss, J. L., 1981, "Statistical Methods for Rates and Proportions" 2nd ed., John Wiley., New York, pp. 38-46.