• 제목/요약/키워드: Quality Measurement Software

Search Result 230, Processing Time 0.032 seconds

Fabrication and Verification of a Water Quality Sensor Equipped with Active RFID Function for Real Time Location (위치추적용 능동형 RFID 기능을 장착한 수질 측정 센서의 제작 및 검증)

  • Jung, Young-Sub;Chang, Hun;Kim, Jin-Young;Kang, Joon-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.1
    • /
    • pp.113-120
    • /
    • 2009
  • Through the automatic sensing of the environment, USN technology can give the best services. In this work, we have developed an active RFID system and examined its performance. By implementing it into water quality sensors, we constructed a system that can detect diverse indoor/outdoor environment and provide information about the pollution level obtained from the temperature and PH sensors. Our RF system had an internal Print-on-PCB antenna for the miniaturization of the tag. We used a RF transceiver CC2510 chipset of TI company to realize the active RFID function. By using RSSI constants obtained, we performed the evaluation of real time location accuracy with a software written in Labview. Among 10 arbitrary locations, we obtained average measurement errors of 1.69 m in x axis and 1.66 m in y axis. This technology can be applied to logistics, environmental monitoring, prevention of missing children and various applications.

  • PDF

Design to Realtime Test Data Topic Utilize of Data Distribution Service (데이터 분산 서비스를 활용한 실시간 시험자료 토픽 설계)

  • Choi, Won-gyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.7
    • /
    • pp.1447-1454
    • /
    • 2017
  • The realtime test data topic means that process for the data efficiently from many kinds of measurement device at the test range. There are many measurement devices in test range. The test range require accurate observation and determine on test object. In this realtime test data slaving framework system, the system can produce variety of test informations and all these data also must be transmitted to test information management or display system in realtime. Using RTI DDS(Data Distribution Service) middle ware Ver 5.2, we can product the efficiency of system usability and QoS(Quality of Service) requirements. So the application user enables to concentrate on applications, not middle ware. As the reason, Complex function is provided by the DDS, not the application such as Visualization Software. In this paper, I suggest the realtime test data topic on slaving framework of realtime test data based on DDS at the test range system.

Examination of Aggregate Quality Using Image Processing Based on Deep-Learning (딥러닝 기반 영상처리를 이용한 골재 품질 검사)

  • Kim, Seong Kyu;Choi, Woo Bin;Lee, Jong Se;Lee, Won Gok;Choi, Gun Oh;Bae, You Suk
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.6
    • /
    • pp.255-266
    • /
    • 2022
  • The quality control of coarse aggregate among aggregates, which are the main ingredients of concrete, is currently carried out by SPC(Statistical Process Control) method through sampling. We construct a smart factory for manufacturing innovation by changing the quality control of coarse aggregates to inspect the coarse aggregates based on this image by acquired images through the camera instead of the current sieve analysis. First, obtained images were preprocessed, and HED(Hollistically-nested Edge Detection) which is the filter learned by deep learning segment each object. After analyzing each aggregate by image processing the segmentation result, fineness modulus and the aggregate shape rate are determined by analyzing result. The quality of aggregate obtained through the video was examined by calculate fineness modulus and aggregate shape rate and the accuracy of the algorithm was more than 90% accurate compared to that of aggregates through the sieve analysis. Furthermore, the aggregate shape rate could not be examined by conventional methods, but the content of this paper also allowed the measurement of the aggregate shape rate. For the aggregate shape rate, it was verified with the length of models, which showed a difference of ±4.5%. In the case of measuring the length of the aggregate, the algorithm result and actual length of the aggregate showed a ±6% difference. Analyzing the actual three-dimensional data in a two-dimensional video made a difference from the actual data, which requires further research.

A Method to Calculate a Pass Rate of the ${\gamma}$-index Analysis in Tomotherapy Delivery Quality Assurance (DQA) (단층치료기를 이용한 방사선 치료의 환자별 정도관리 평가를 위한 감마인덱스의 정량화 방법)

  • Park, Dahl;Kim, Yong-Ho;Kim, Won-Taek;Kim, Dong-Won;Kim, Dong-Hyun;Jeon, Ho-Sang;Nam, Ji-Ho;Lim, Sang-Wook
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.340-347
    • /
    • 2010
  • DQA, a patient specific quality assurance in tomotherapy, is usually performed using an ion chamber and a film. The result of DQA is analysed with the treatment planning system called Tomo Planning Station (TomoPS). The two-dimensional dose distribution of film measurement is compared with the dose distribution calculated by TomoPS using the ${\gamma}$-index analysis. In ${\gamma}$-index analysis, the criteria such as 3%/3 mm is used and we verify that whether the rate of number of points which pass the criteria (pass rate) is within tolerance. TomoPS does not provide any quantitative information regarding the pass rate. In this work, a method to get the pass rate of the ${\gamma}$-index analysis was suggested and a software PassRT which calculates the pass rate was developed. The results of patient specific QA of the intensity modulated radiation therapy measured with I'mRT MatriXX (IBA Dosimetry, Germany) and DQA of tomotherapy measured with film were used to verify the proposed method. The pass rate was calculated using PassRT and compared with the pass rate calculated by OmniPro I'mRT (IBA Dosimetry, Germany). The average difference between the two pass rates was 0.00% for the MatriXX measurement. The standard deviation and the maximum difference were 0.02% and 0.02%, respectively. For the film measurement, average difference, standard deviation and maximum difference were 0.00%, 0.02% and 0.02%, respectively. For regions of interest smaller than $24.3{\times}16.6cm^2$ the proposed method can be used to calculate the pass rate of the gamma index analysis to one decimal place and will be helpful for the more accurate DQA in tomotherapy.

Analytical and experimental study on the quality improvement of 2 cavity injection-molded LCD frame (2 캐비티 LCD 사출품의 품질향상에 관한 해석 및 실험적 연구)

  • Son, Jae-Hwan;Jang, Eun-Sil;Han, Chang-Woo;Son, Jae-Yong;Lee, Young-Moon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3815-3821
    • /
    • 2012
  • The LCD frame is an important part which supports the BLU of medium/large sized TFT-LCD. To produce it efficiently, it is necessary to achieve the molding process improvement from 1 cavity to 2 cavity system. Because 2 cavity mold is compact and its hot-runner zone is broadened, it is difficult to control the temperature on the mold. In this study, injection molding analysis on the frame in 2 cavity process with FEA(Finite Element Analysis) software is carried out to estimate its quality. The calculated injection molding pressures and maximum deflection in 1 and 2 cavity processes are 41.13 MPa and 1.62 mm, 40.49 MPa and 1.66 mm respectively. The measured maximum flexure load and surface roughness of the left and right frame of 2 cavities are 209 N and 0.08 ${\mu}m$, 193 N and 0.10 ${\mu}m$ while those in 1 cavity are 140 N and 0.13 ${\mu}m$. Thermal image shows that the maximum standard deviation of the temperature on left and right side of 2 cavity mold is $1.23^{\circ}C$. The simulation and measurement results show that the quality of the frame in 2 cavity injection molding process as a whole is not worse than that of 1 cavity system. But maximum flexure loads of the frame in 2 cavity process are far greater than that in 1 cavity process.

Evaluating analytical and statistical models in order to estimate effective grouting pressure

  • Amnieh, Hassan Bakhshandeh;Masoudi, Majid;Karbala, Mohammdamin
    • Computers and Concrete
    • /
    • v.20 no.3
    • /
    • pp.275-282
    • /
    • 2017
  • Grouting is an operation often carried out to consolidate and seal the rock mass in dam sites and tunnels. One of the important parameters in this operation is grouting pressure. In this paper, analytical models used to estimate pressure are investigated. To validate these models, grouting data obtained from Seymareh and Aghbolagh dams were used. Calculations showed that P-3 model from Groundy and P-25 model obtained from the results of grouting in Iran yield the most accurate predictions of the pressure and measurement errors compared to the real values in P-25 model in this dams are 12 and 14.33 Percent and in p-3 model are 12.25 and 16.66 respectively. Also, SPSS software was applied to define the optimum relation for pressure estimation. The results showed a high correlation between the pressure with the depth of the section, the amount of water take, rock quality degree and grout volume, so that the square of the multiple correlation coefficient among the parameters in this dams were 0.932 and 0.864, respectively. This indicates that regression results can be used to predict the amount of pressure. Eventually, the relationship between the parameters was obtained with the correlation coefficient equal to 0.916 based on the data from both dams generally and shows that there is a desirable correlation between the parameters. The outputs of the program led to the multiple linear regression equation of P=0.403 Depth+0.013 RQD+0.011 LU-0.109 V+0.31 that can be used in estimating the pressure.

A Study on Evaluation Criteria for quantitatively OSS Selection (정량적인 OSS 선정을 위한 평가지표 연구)

  • Lee, Hoo-Jae;Kim, Doo-Yeon;Choi, Il-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1863-1871
    • /
    • 2012
  • Utilization of the former OSS was mainly focused on the usage of system applications such as operating system and DBMS. However, nowadays many companies are trying to make use of OSS based on the application rather than the system software. However, selection of base OSS is the most important to develop of application for utilizing OSS. The scope of existing OSS evaluation studies is covered the entire OSS quality. Thus existing studies of evaluation of OSS selection is insufficient. Also, the result of assessment is based on qualitative measurement rather than quantitative ones. In this paper, we derives only the indicators for selection among the existing OSS assessment indicators and suggests the assessment indicator that is capable of quantitative assessment in accordance with the characteristics of the project. The proposed assessment indicator is divided into an initial assessment indicator that can be assessed with only the information within the OSS community, and the detailed assessment indicator through metrics to make quantitative measurements possible. In this way, an objective basis can be provided through quantitative scores & indicators when selecting OSS.

A Study on the Analysis of $CO_2$ Concentration Variation According to the Indoor Space Condition Changes (다양한 실내 환경에서의 $CO_2$ 농도 변화 분석 연구)

  • Ahn, Gwang-Hoon;Kwon, Jong-Won;Kim, Gyu-Sik;Kim, Hie-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.347-349
    • /
    • 2009
  • Air quality of indoor space environment is affected by various pollutants like as particles and chemical stuffs. The indoor air pollution affects directly the human respiration organs to cause consequently unpleasant mental status. The $CO_2$ concentration level is one of the harmful components of air pollutants. Major factor to increase the $CO_2$ concentration level is the people's breath amount in indoor. The car exhaust gas diffused from the around road also has strong affect on $CO_2$ concentration. There are some other reasons to affect the $CO_2$ concentration change, such as, real-time change of the population movement, closeness to the indoor air flow inlet window and changes in road car traffic amount. A remote monitoring system to measure environmental indoor air pollution concerning on the $CO_2$ concentration was studied and installed realized set-up model. Zigbee network configuration was applied for this system and the $CO_2$ concentration data were collected through USN network. A software program was developed to assure systematic analysis and to display real-time data on web pages. For the experimental test various condition was set up, like as, window opening, stopping air condition operation and adjusting fan heater work, etc. The analysis result showed the relation of various environmental conditions to $CO_2$ concentration changes. The causes to increase $CO_2$ concentration were experimentally defined as windows closing, the stopping air condition system, fan heater operation. To keep the $CO_2$ concentration under the legally required ppm level in public access indoor space, the developed remote measurement system will be usefully applied.

  • PDF

The development of pH reading system based on vision system (영상 기반 pH 산도 측정 시스템 개발)

  • Moon, Ha-Jung;Lee, Dong-Hoon
    • Journal of IKEEE
    • /
    • v.17 no.4
    • /
    • pp.398-406
    • /
    • 2013
  • Nuclear medicine imaging devices such as PET diagnose disease after injecting radiopharmaceuticals in human body for diagnosis. Radiopharmaceuticals should maintain the proper pH for human body safety. In general, pH paper is used to measure the pH of the radiopharmaceutical. pH of the sample compared with the standard color chart is used for measurement. However, the pH reading difference according to the experience of a rater can be generated. Also, a pH meter for measuring pH has a high sensitivity and contamination of the sensor must be avoided. In this paper, we developed the new hardware device for pH reading method and software was developed with vision algorithm to measure pH easily and simply.

Feasibility Study of Source Position Verification in HDR Brachytherapy Using Scintillating Fiber

  • Moon, Sun Young;Jeong, EunHee;Lim, Young Kyung;Chung, Weon Kyu;Huh, Hyun Do;Kim, Dong Wook;Yoon, Myonggeun
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.213-219
    • /
    • 2016
  • The position verification of the radiation source utilized in brachytherapy forms a critical factor in determining the therapeutic efficiency. Currently, films are used to verify the source position; however, this method is encumbered by the lengthy time interval required from film scanning to analysis, which makes real-time position verification difficult. In general, the source position accuracy is usually tested in a monthly quality assurance check. In this context, this study investigates the feasibility of the real-time position verification of the radiation source in high dose rate (HDR) brachytherapy with the use of scintillating fibers. To this end, we construct a system consisting of scintillating fibers and a silicon photomultiplier (SiPM), optimize the dosimetric software setup and radiation system characteristics to obtain maximum measurement accuracy, and determine the relative ratio of the measured signals dependent upon the position of the scintillating fiber. According to the dosimetric results based on a treatment plan, in which the dwell time is set at 30 and 60 s at two dwell positions, the number of signals is 31.5 and 83, respectively. In other words, the signal rate roughly doubles in proportion to the dwell time. The source position can also be confirmed at the same time. With further improvements in the spatial resolution and scintillating fiber array, the source position can be verified in real-time in clinical settings with the use of a scintillating fiber-based system.