• Title/Summary/Keyword: QC

Search Result 473, Processing Time 0.027 seconds

Research on the use of Therapeutic Linear accelerator Quality Control using EPR/alanine Dosimeter (EPR/알라닌 선량계를 이용한 치료용 선형가속기 정도관리 활용 연구)

  • Yoon-Ha Kim;Hyo-Jin Kim;Yeong-Rok Kang;Dong-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.239-248
    • /
    • 2024
  • Radiation therapy uses high energy, which can have side effects on the human body. Therefore, it is important to ensure that the appropriate dose is set for irradiation and to have confidence in the radiation produced by the generator. The EPR/Alanine dosimetry system is characterized by water equivalence, dose response linearity, and low fading, which makes it useful for quality control of radiation therapy equipment. In this study, we compared the signal and dose response curves of EPR/Alanine dosimetry by mass of alanine using 6 MV energy of a LINAC. An alanine dosimeter and EPR spectrometer from Burker, and a LINAC from Elekta, were used. A dose response curve and a 1st order regression equation were constructed from the irradiated dose and the EPR signal from the alanine dosimeter. We compared the signal magnitude and dose response curve with mass and checked the confidence through the measurement uncertainty of the dose response curve. As a result, it was found that the magnitude of the EPR signal increased by about 1.3 times at 64.5 mg, and the sensitivity of the dose response curve increased as the mass increased. The measurement uncertainty was evaluated to be between 5.84 % and 8.93 %. Through this study, it is expected that the EPR/alanine dosimetry system can be applied to the quality assurance and quality control of a LINAC.

Determination of methamphetamine, 4-hydroxymethamphetamine, amphetamine and 4-hydroxyamphetamine in urine using dilute-and-shoot liquid chromatography-tandem mass spectrometry (시료 희석 주입 LC-MS/MS를 이용한 소변 중 메스암페타민, 4-하이드록시메스암페타민, 암페타민 및 4-하이드록시암페타민 동시 분석)

  • Heo, Bo-Reum;Kwon, NamHee;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.161-170
    • /
    • 2018
  • The epidemic of disorders associated with synthetic stimulants, such as methamphetamine (MA) and amphetamine (AP), is a health, social, legal, and financial problem. Owing to the high potential of their abuse and addiction, reliable analytical methods are required to detect and identify MA, AP, and their metabolites in biological samples. Thus, a dilute-and-shoot liquid chromatography-tandem mass spectrophotometry (LC-MS/MS) was developed for simultaneous determination of MA, 4-hydroxymethamphetamine (4HMA), AP, and 4-hydroxyamphetamine (4HA) in urine. Urine sample ($100{\mu}L$) was mixed with $50{\mu}L$ of mobile phase consisting of 0.4 % formic acid and methanol and $50{\mu}L$ of working internal-standard solution. Aliquots of $8{\mu}L$ diluted urine was injected into the LC-MS/MS system. For all analytes, chromatographic separation was performed using a C18 reversed-phase column with gradient elution and a total run time of 5 min. The identification and quantification were performed by multiple reaction monitoring (MRM). Linear least-squares regression was conducted to generate a calibration curve, with $1/x^2$ as the weighting factor. The linear ranges were 2.0-200, 1.0-800, and 10-2500 ng/mL for 4HA and 4HMA, AP, and MA, respectively. The inter- and intraday precisions were within 6.6 %, whereas the inter- and intraday accuracies ranged from -14.9 to 11.3 %. The low limits of quantification were 2.0 ng/mL (4HA and 4HMA), 1.0 ng/mL (AP), and 10 ng/mL (MA). The proposed method exhibited satisfactory selectivity, dilution integrity, matrix effect, and stability, which are required for validation. Moreover, the purification efficiency of high-speed centrifugation was clearly higher than 6-15 % for QC samples (n=5), which was higher than that of the membrane-filtration method. The applicability of the proposed method was tested by forensic analysis of urine samples from drug abusers.

Suitability Assessment of Domestic Natural Waters as a Culture Medium for Daphnia magna (Daphnia magna의 배양배지로서 국내 자연수의 적절성 평가)

  • Yeom, Dong-Hyuk;Jeon, Chan-Sig
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.3
    • /
    • pp.271-277
    • /
    • 2012
  • The present study was conducted to assess the suitability of domestic natural waters as a Daphnia magna culture medium. In order to assess survival rate and reproductive output, young female daphnids (parent animals), aged less than 24 hours at the start of the test and produced in the Elendt M4 medium, were exposed to Elendt M4 medium, de-chlorinated tap water, and natural mineral water for 21 days. D. magna cultured in Elendt M4 medium (reference medium) and natural mineral water met the criteria of OECD No. 211, Daphnia magna Reproduction Test Guidelines in terms of percent adult survival, first day of reproduction, and average young production. However, the mortalities of adult daphnids observed in de-chlorinated tap water were more than 20% in two reproduction tests for 21 days. Mortality was observed on exposure days 13, 15, and 18 in de-chlorinated water. The use of D. magna is recommended in water of hardness >80 mg $CaCO_3\;L^{-1}$. However, the hardness of de-chlorinated tap water used in the present study was 50~53 mg $CaCO_3\;L^{-1}$. Therefore, it is judged that the delayed mortalities observed in de-chlorinated tap water were caused by a rapid decreased in hardness when the medium was changed from Elendt M4 to de-chlorinated tap water. When D. magna is cultured using domestic natural waters (underground water, surface water, and de-chlorinated water), the quality-control (QC) data should be maintained through a standardization for health assessment method, toxicity test method using reference chemical, test intervals of reference toxicant toxicity test, and data treatment and interpretation. In the long term, national research programs are needed for the development of test species which are representative of domestic aquatic environmental conditions among indigenous daphnids.

Quantitative Analysis of Paeoniflorin and Paeonol in Peony Extracts and Quality Control Standards (모란 추출액에서 paeoniflorin과 paeonol 동시 정량 분석 및 화장품 원료의 품질관리 기준 설정)

  • Yun, Ki-Hun;Chi, Yong-Ha;Lee, Dong-Kyu;Paik, Soo-Heui
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.235-246
    • /
    • 2018
  • Paeony has pharmacological activities such as anti-inflammatory, anti-allergic, anti-bacterial, central inhibitory, gastric secretion inhibition, and antispasmodic activities. In addition, its antioxidant activity and whitening effect being reported, thus it is being explored as raw materials for cosmetics. We compared the changes in the contents of paeoniflorin and paeonol in Peony extracts, depending on the changes of extracting solvents, temperature and time. The HPLC method was set up for simultaneous analysis, the system suitabilities were confirmed by using the calibration curves and the QC samples for each assay batch. Paeonol was detected only in roots, and paeoniflorin was higher in leaf and flower than root. Higher concentrations of both ingredients were extracted when the root was used after grinding to a suitable size, and when 30% 1,3-butylene glycol was used as the extraction solvent. Also the concentrations tended to increase at higher temperature and longer time, but the increase was gradual at over $75^{\circ}C$ and 4 hours. The ratio of root, leaf and flower was determined to be 2+2+1g/0.5kg of batch, reaching the contents criteria of paeoniflorin and paeonol. Finally, we selected as the best extraction condition when the raw materials are mixed with 2+2+1g/0.5kg and extracted with 30% 1,3-butylene glycol as an extraction solvent at $75^{\circ}C$ for 4 hours, considering both the concentrations of two components and the cost of raw materials and manufacturing process, The extraction units were scaled up to 10 kg under this condition.

Role of Radiation Therapy for Stage III Thymoma (제 3기 흉선종에서 방사선치료의 역할)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.16-20
    • /
    • 2001
  • Purpose : To evaluate the effectiveness and tolerance of the postoperative radiation therapy for patients with Stage III thymoma and to define the optimal radiotherapeutic regimen Materials and Methods : We retrospectively analyzed the records of 24 patients with Stage III thymoma who were referred for postoperative radiation therapy in our institution from June, 1987 to May, 1999. Surgical therapy consisted of total resection in one patient, subtotal resection in seventeen, and biopsy alone in six patients. Age of the patients was ranged from 20 to 62 years with mean age of 47 years. Male to female ratio was 14 to 10. Radiation therapy was delivered with linear accelerator producing either 6 MeV or 10 MeV photons. The irradiated volume included anterior mediastinum and known residual disease. The supraclavicular fossae were not irradiated. The delivered total dose was ranged from 30 to 56 Gy. One patient received 30 Gy and eighteen patients received minimum of 50 Gy. Follow up period was ranged from 12 months to 8 years with median follow up of 40 months. Results : The overall local control rate for entire group of patients was $67\%$ at 5 years. The cumulative local failure rates at one, three and five year were $18\%,\;28\%\;and\;33\%$, respectively. In patients treated with subtotal resection and biopsy alone, local control rate was $76\%\;and\;33\%$, respectively. The actuarial observed survival rate at 5 years was $57\%$, and actuarial adjusted survival at 5 years was $72\%$. The difference between 5 year survival rates for patients treated with subtotal resection and biopsy alone was not statistically significant $(62\%\;vs\;30\%)$. Conclusion : We might conclude that postoperative radiation therapy was safe and effective treatment for patients with Stage III thymoma. Postoperative radiation therapy is recommended in cases where tumor margin is close or incomplete resection is accomplished.

  • PDF

Effects of different cooking methods on folate retention in selected mushrooms (다양한 조리법에 따른 버섯류의 엽산 리텐션)

  • Park, Su-Jin;Park, Sun-Hye;Chung, Heajung;Lee, Junsoo;Hyun, Taisun;Chun, Jiyeon
    • Food Science and Preservation
    • /
    • v.24 no.8
    • /
    • pp.1103-1112
    • /
    • 2017
  • This study was performed to investigate the effects of different cooking methods (boiling, roasting, stir-frying, and deep-frying) on folate retention in 6 kinds of mushrooms (Beech-, button-, Juda's ear-, oak-, oyster-, and winter-mushrooms) frequently consumed in Korea. In order to assure reliability of analytical data, trienzyme extraction-L casei method was verified and analytical quality control was also evaluated. Folate contents of mushrooms varied by 6.04-64.82 g/100 g depending on the type of mushrooms. and were significantly affected by cooking methods. Depending on cooking methods, folate contents of mushrooms decreased by 22-48%, 2-31%, and 17-56% for Juda's ear-, oak- and oyster-mushrooms, respectively, while 17-90% of folate was increased in Beech mushroom. Overall, the largest weight loss was found in boiled mushrooms, but the lowest one in deep-fried samples. True folate retention rates considering processing factor were less than 100% for all cooked mushrooms except for Beech samples. Overall, folate loss was the largest by boiling with water but the smallest by deep-frying. Both accuracy and precision of trienzyme extraction-L-casei method were excellent based on a recovery close to 100% and coefficient variations less than 3%. Quality control chart of folate analysis (n=26) obtained during the entire study and an international proficiency test (z-score=-0.5) showed that trienzyme extraction-L casei method is reliable enough for production of national folate database.

Application of Machine Learning Algorithm and Remote-sensed Data to Estimate Forest Gross Primary Production at Multi-sites Level (산림 총일차생산량 예측의 공간적 확장을 위한 인공위성 자료와 기계학습 알고리즘의 활용)

  • Lee, Bora;Kim, Eunsook;Lim, Jong-Hwan;Kang, Minseok;Kim, Joon
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_2
    • /
    • pp.1117-1132
    • /
    • 2019
  • Forest covers 30% of the Earth's land area and plays an important role in global carbon flux through its ability to store much greater amounts of carbon than other terrestrial ecosystems. The Gross Primary Production (GPP) represents the productivity of forest ecosystems according to climate change and its effect on the phenology, health, and carbon cycle. In this study, we estimated the daily GPP for a forest ecosystem using remote-sensed data from Moderate Resolution Imaging Spectroradiometer (MODIS) and machine learning algorithms Support Vector Machine (SVM). MODIS products were employed to train the SVM model from 75% to 80% data of the total study period and validated using eddy covariance measurement (EC) data at the six flux tower sites. We also compare the GPP derived from EC and MODIS (MYD17). The MODIS products made use of two data sets: one for Processed MODIS that included calculated by combined products (e.g., Vapor Pressure Deficit), another one for Unprocessed MODIS that used MODIS products without any combined calculation. Statistical analyses, including Pearson correlation coefficient (R), mean squared error (MSE), and root mean square error (RMSE) were used to evaluate the outcomes of the model. In general, the SVM model trained by the Unprocessed MODIS (R = 0.77 - 0.94, p < 0.001) derived from the multi-sites outperformed those trained at a single-site (R = 0.75 - 0.95, p < 0.001). These results show better performance trained by the data including various events and suggest the possibility of using remote-sensed data without complex processes to estimate GPP such as non-stationary ecological processes.

Efficient Application of Westgard Multi-Rules and Quality Control Implementation Improvement (Westgard Multi-Rules의 효율적 적용과 조치사항의 개선)

  • Jung, Heung Soo;Oh, Youn Jung;Bae, Jin Soo;Baek, Jin Young;Hwang, Bo ra;Shin, Yong Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.60-64
    • /
    • 2017
  • Purpose Westgard multi-rules application based on test quality improvement and commercialized international standard has been widely used in quality control. However, it is difficult to applicate the Westgard multi-rules in nuclear medicine in vitro tests due to the larger sample sizes and the simultaneous measurement of quality control material and patient sample. This study investigated the usefulness of Westgard multi-rules application in nuclear medicine in vitro tests. Materials and Methods A total of 282 systematic error multi-rules (22s, 101s) recorded in the samsung medical center computer system from January 2013 to June 2016 along with 117 cases of corrective measure record was analyzed. The Quality control implementation is recorded in Hospital information system were divided into 4 high-level areas including quality control material error, experimental procedural error, Kit lot number management error, and others. To prevent quality control material error, the existing method that each staff used their own method was changed. The staff who in charge of managing the quality control material was designated and daily consumption amount of every test was strictly controlled by one person. To prevent other errors, every test step was standardized so that the entire test procedures are identically implemented. Results The total quality control implementation was 117 cases; As a result, 62 quality control material errors were 62 cases, experimental process errors were 24 cases, Kit lot number control errors were 18 cases, and other errors were 13 cases. The quality control material error was corrected and could be used fresh materials within 2 days after thawing. The cases of systemic error were decreased to causes as quality control material error. The quality control materials were reduced above 10 vials to a monthly average. In addition, these errors of experimental processing and Kit lot number were improved by test standardization. Consequently, the cases of 101s and 22s in systematic error rules decreased at least 2 cases to a monthly average. Conclusion To confirm of systematic error through multi-rules application quickly, it is necessary to base on management of the QC material, target values and standard deviation. Moreover, in the event of a systematic error, it was found important to record measures based on test cause analysis. The experiment results are expected to contribute to internal quality control improvement and prompt and accurate result reporting through error recording and causal analysis based on Westgard multi-rules analysis.

  • PDF

Antioxidative Activity and Component Analysis of Quercus glauca Leaf Extracts (종가시나무 잎 추출물의 항산화 활성, 성분 분석)

  • Yang, Hee-Jung;Ahn, You-Jin;Kim, Jae-Hyun;Park, Soo-Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.3
    • /
    • pp.189-200
    • /
    • 2008
  • In this study, the antioxidative effects, inhibitory effects on elastase, and components of Quercus glauca extracts were investigated. The free radical (1,1-diphenyl-2-picrylhydrazyl, DPPH) scavenging activity $(FSC_{50})$ of extract I fractions of Quercus glauca leaf was in the order: 50% ethanol extract $(12.45{\mu}g/mL)$ < ethyl acetate fraction $(10.47{\mu}g/mL)$ < deglycosylated flavonoid aglycone fraction $(8.57{\mu}g/mL)$. Reactive oxygen species (ROS) scavenging activities $(OSC_{50})$ of some Quercus glauca leaf extracts on ROS generated in $Fe^{3+}-EDTA/H_2O_2$ system were investigated using the luminol-dependent chemiluminescence assay. The order of ROS scavenging activity was 50% ethanol extract $(OSC_{50},\;4.2{\mu}g/mL)$ < deglycosylated flavonoid aglycone fraction $(1.58{\mu}ug/mL)$ < ethyl acetate fraction $(0.66{\mu}g/mL)$. Ethyl acetate fraction showed the most prominent scavenging activity. The protective effects of extract / fractions of Quercus glauca leaf on the rose-bengal sensitized photohemolysis of human erythrocytes were investigated. The Quercus glauca leaf extracts suppressed photohemolysis in a dose dependent manner, particularly deglycosylated flavonoid aglycone fraction exhibited the most prominent celluar protective effect $({\tau}_{50}$, 398.67 min at $50{\mu}g/mL$). Aglycone fractions obtained from the deglycosylation reaction of ethyl acetate fraction among the Quercus glauca leaf extracts, showed 2 bands in TLC and 2 peaks in HPLC experiments (360 nm) as well. Two components were identified as quercetin (55.77%), and kaempferol (44.23 %). TLC chromatogram of ethyl acetate fraction of Quercus glauca leaf extracts revealed 6 bands $(QG1{\sim}QG6)$, Among them, isoquercitrin (QG3), hyperin (QG4), and rutin (QG6) were identified. The inhibitory effect of aglycone fraction on tyrosinase $(IC_{50},\;73.5{\mu}g/mL)$ and elastase $(IC_{50},\;16.2{\mu}g/mL)$ was high. These results indicate that extract / fractions of Quercus glauca can function as antioxidants in biological systems, particularly skin exposed to UV radiation by scavenging $^1O_2$ and other ROS, and protect cellular membranes against ROS. And component analysis of Quercus glauca leaf extract and inhibitory activity on tyeisinase and elastase of the aglycone fraction could be applicable to new functional cosmetics.

Prediction of Entrance Surface Dose in Chest Digital Radiography (흉부 디지털촬영에서 입사표면선량 예측)

  • Lee, Won-Jeong;Jeong, Sun-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.573-579
    • /
    • 2019
  • The purpose of this study is predicted easily the entrance surface dose (ESD) in chest digital radiography. We used two detector type such as flat-panel detector (FP) and IP (Imaging plate detector). ESD was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image. Dose-area product (DAP) or exposure index (EI) was checked by Digital Imaging and Communications in Medicine (DICOM) header on phantom images. Statistical analysis was performed by the linear regression using SPSS ver. 19.0. ESD was significant difference between FP and IP($85.7{\mu}Gy$ vs. $124.6{\mu}Gy$, p=0.017). ESD was positively correlated with image quality in FP as well as IP. In FP, adjusted R square was 0.978 (97.8%) and linear regression model was $ESD=0.407+68.810{\times}DAP$. DAP was 4.781 by calculating the $DAP=0.021+0.014{\times}340{\mu}Gy$. In IP, adjusted R square was 0.645 (64.5%) and linear regression model was $ESD=-63.339+0.188{\times}EI$. EI was 1748.97 by calculating the $EI=565.431+3.481{\times}340{\mu}Gy$. In chest digital radiography, the ESD can be easily predicted by the DICOM header information.