• Title/Summary/Keyword: Purpose of use

Search Result 19,341, Processing Time 0.055 seconds

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.

  • PDF

Clinical effects of additional use of erythritol powder air polishing device on non-surgical periodontal treatment in moderate chronic periodontitis (중등도 만성 치주염 환자에서 erythritol 공기분말 연마기구를 부가적으로 이용하는 비외과적 치주치료의 임상적 효과)

  • Lee, Mun-Young;Park, Eon-Jeong;Kwon, Eun-Young;Kim, Hyun-Joo;Lee, Ju-Youn;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.39-45
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the clinical effects of erythritol powder air polishing device (EPAP) in addition to scaling and root planing (SRP) in non-surgical periodontal treatment in moderate chronic periodontitis patients. Materials and Methods: Clinical evaluation was performed at 21 sites treated with SRP (control) and 21 sites treated with the addition of SRP+EPAP (test). All examinations were performed before treatment, 1 month after treatment, and 3 months after treatment. Depth of the periodontal pocket, gingival recession, clinical attachment level, plaque index, and bleeding of probing were measured as clinical parameters. Results: In both test and control groups, there was a significant decrease in the depth of the periodontal pocket, plaque index, bleeding of probing, increased gingival recession, and gain of clinical attachment level at 1 month and 3 months after treatment. However, there was no significant clinical difference between the test group and the control group. Clinical result was improved after 1 month compared to the baseline; in contrast, results at 3 months after treatment were worse than at 1 month after treatment. Conclusion: In this study, we cannot suggest that SRP + EPAP is clinically more effective than SRP alone as non-surgical periodontal treatments. Periodic periodontal therapy, at intervals of at least every three months, is important for sustaining effects of this treatment.

A Study on the Effectiveness of 3PL Logistics Information System : A Focus on the Role of Supply Chain Performance in Shipper and Long-term Relationship intention (3PL 물류정보시스템의 효과성에 관한 실증적 연구 : 화주기업의 공급사슬성과와 장기지향적관계성의 역할을 중심으로)

  • Cho, Jae-yong
    • Journal of Venture Innovation
    • /
    • v.3 no.2
    • /
    • pp.111-128
    • /
    • 2020
  • Recently, in the process of globalization of companies, the use of third party logistics providers (3PL) has been strengthened. Therefore, the purpose of this study is to test the effectiveness of the logistics information system provided by 3PL companies. This study is to test the relationship between the effect of the characteristics of the 3PL logistics information system on the shipper's supply chain performance, that is, logistics performance, customer performance, and organizational performance, and the shipper's loyalty to the 3PL company, that is, 3PL corporate performance. In addition, long-term relationship orientation is to test whether there is a moderating effect between the shipper company and the 3PL company. Through this, this study aims to provide strategic implications for improving the competitiveness of 3PL companies. In this study, a total 205 data were collected and used for analysis of shippers companies for hypothesis testing, and analyzed using SPSS 21.0 and AMOS 21.0 statistical programs. The results of the study are summarized as follows. First, it was found that the accuracy, timeliness, and usefulness of the 3PL logistics information system all had a significant positive (+) effect on the performance of the shipper's supply chain. Second, it was found that the accuracy, timeliness, and usefulness of the 3PL logistics information system all had a significant positive (+) effect on 3PL corporate performance. Third, it was found that the performance of the supply chain of the shipper company had a significant positive (+) effect on the performance of the 3PL company. Finally, it was found that long-term relationship orientation had a moderating effect on the relationship between the performance of the shipper company's supply chain and the performance of the 3PL company. The purpose of this study is to provide academic and practical implications for securing competitive advantage through the logistics information system of 3PL logistics companies.

Relationship between exhaled nitric oxide and pulmonary function test in children with asthma (소아 천식에서 호기산화질소와 폐기능 검사의 관계)

  • Ko, Han-Seok;Chung, Sung-Hoon;Choi, Yong-Sung;Choi, Sun-Hee;Rha, Yeong-Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.2
    • /
    • pp.181-187
    • /
    • 2008
  • Purpose : Asthma is characterized by reversible airway obstruction and bronchial hyperresponsiveness result from airway inflammation. Fraction of nitric oxide in expired air (FeNO) has recently been investigated as a noninvasive measure of airway inflammation. FeNO has been reported to correlate with induced sputum eosinophilia and methacholine challenge test that it is represent severity of asthma. The purpose of this study was to analyze the relationship of FeNO with pulmonary function tests in patients with intermittent asthma. Methods : Eighty children included in this study were diagnosed as asthma from April through August, 2005 in Department of Pediatrics, College of Medicine, Kyunghee University. They aged from 4 to 15 years who were able to conduct spirometry and FeNO monitoring. They did not have upper respiratory tract infection and did not use an asthma controller which contain corticosteroids within 4 weeks. Pulmonary function test was done and FeNO was measured with online tidal breathing method using a chemiluminescence NO analyzer (CLD 88 sp, Eco Medics, Duernten, Switzerland). The correlations between pulmonary function test and FeNO were analyzed using Spearman correlation coefficient method. Results : The mean of FeNO of subject was 16.88 parts per billion (ppb). The mean of forced expiratory volume in 1 second ($FEV_1$) was $0.890{\pm}0.455L$ and forced vital capacity (FVC) was $1.071{\pm}0.630L$. The mean of predicted $FEV_1%$ ($FEV_1%pred$) was $98.39{\pm}34.27%$ and $FEV_1/FVC$ was $88.53{\pm}19.49$. FeNO was significantly correlate with $FEV_1$ (r=0.345, P<0.01) and FVC (r=0.244, P<0.05). FeNO did not correlate with $FEV_1%pred$ or $FEV_1/FVC$. Conclusion : The measurement of FeNO could be a useful marker in the management of childhood asthma and it is evolving to provide a complementary role alongside existing pulmonary function test. We propose that measuring technique and establishment of normal reference range are important area for future research.

The Study for clinical application of The New Sasang Constitution Questionnaire (새로운 사상체질 설문지의 임상적 활용에 관한 연구)

  • Kim, Tae-gyun;Kim, Jong-weon
    • Journal of Sasang Constitutional Medicine
    • /
    • v.12 no.1
    • /
    • pp.173-185
    • /
    • 2000
  • 1. The purpose of study The purpose of study is The New Sasang Constitution Questionnaire to improve clinical right, as the person takes off uncomfortable to must use both Questionnaire of Sasang Constitution Classification II (QSCC) and Questionnaire of Sasang Classification(I) 2. The method of study I made the judgmental equation, increasing ability of judgment to give thinking importance among each subject about a Clinical study of judgment and the method of using, I investigated which Equation is better by a Clinical Study of the judgment. I made Equation, 9 and examine the Accuracy rate of the judgment through patients, student of University formal peoples and peoples taking the drugs 304 member totally. 3. The result of study I made 9 Equation of the judgment. The Equation of the judgment(I-2) is the highest ability of the judgment, the diagnostic accuracy is 60.53% about Soeum, 52.78% about Taeum, 48.39 about Soyang.

  • PDF

An experimental study of cutting efficiency of air-driven diamond burs on human tooth (수종 air-turbine 다이아몬드 버의 절삭 효과에 관한 실험적 연구)

  • Hong, Jin-Sun;Yeo, In-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the cutting efficiency of coarse grit diamond burs with air-turbine handpiece on natural tooth. Materials and methods: Four groups of coarse grit diamond bur were selected: Komet (A), Shofu (B), Premier (C), and Mani (D). The extracted maxillary central incisors were used, and ten cuts were made on each specimen, using the rotary diamond burs. The surface of each bur was measured at the upper, middle, and bottom of the bur with confocal laser scanning microscope and imaged with SEM. The data were analyzed with one-way ANOVA and t-test at the significance level of 0.05. Results: The surface roughness was measured. At the A diamond bur, the Sa values were $52.93\;{\mu}m$, $48.32\;{\mu}m$, $46.79\;{\mu}m$, $45.06\;{\mu}m$, and $43.43\;{\mu}m$ for control, test 1, 2, 3, and 4 respectively. The Sa values were $50.68\;{\mu}m$, $45.62\;{\mu}m$, $44.41\;{\mu}m$, $44.10\;{\mu}m$, and $42.46\;{\mu}m$ for B diamond bur, $58.02\;{\mu}m$, $55.53\;{\mu}m$, $52.22\;{\mu}m$, $48.26\;{\mu}m$, and $45.36\;{\mu}m$ for C diamond bur, and $50.11\;{\mu}m$, $46.73\;{\mu}m$, $45.46\;{\mu}m$, $42.58\;{\mu}m$, and $41.80\;{\mu}m$ for D diamond bur. Surface roughness after each bur use showed significant changes, but no significant difference was found in surface roughness change between bur systems. Conclusions: Surface roughness in the same bur system showed significant differences after each tooth preparation. However no statistically significant differences were found in surface roughness between bur systems. The SEM images between control and test 4 showed the abraded particles.

Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer (조기유방암환자의 이차원치료계획과 삼차원치료계획의 방사선조사범위의 차이)

  • Jo, Sun-Mi;Chun, Mi-Son;Kim, Mi-Hwa;Oh, Young-Taek;Kang, Seung-Hee;Noh, O-Kyu
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • Purpose: Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Materials and Methods: Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inframammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. Results: The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. Conclusion: The use of 3D CT based planning reduced the radiation field in early breast cancer patients with small breasts in relation to conventional planning. Though a coherent definition of the breast is needed, CT-based planning generated the better plan in terms of reducing the irradiation volume of normal tissue. Moreover it was possible that 3D CT based planning showed better CTV coverage including postoperative change.

The Variation of Surface Dose by Beam Spoiler in 10 MV Photon Beam from Linear Accelerator (선형가속기 10 MV 광자선에서 산란판(Beam Spoiler) 사용 시 표면선량 변화)

  • Bae, Seong-Cheol;Kim, Jun-Ho;Lee, Choul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • Purpose: The purpose of this study is to find a optimal beam spoiler condition on the dose distribution near the surface, when treating a squamous cell carcinoma of the head and neck and a lymphatic region with 10 MV photon beam. The use of a optimal spoiler allows elivering high dose to a superficial tumor volume, while maintaining the skin-sparing effect in the area between the surface to the depth of 0.4 cm. Materials and Methods: The lucite beam spoiler, which were a tissue equivalent, were made and placed between the surface and the photon collimators of linear accelerator. The surface-dose, the dose at the depth of 0.4 cm, and the maximum dose at the dmax were measured with a parallel-plate ionization chamber for $5{\times}5cm\;to\;30{\times}30cm^2$ field sizes using lucite spoilers with different thicknesses at varying skin-to-spoiler separation (SSS). In the same condition, the dose was measured with bolus and compared with beam spoiler. Results: The spoiler increased the surface and build-up dose and shifted the depth of maximum dose toward the surface. With a 10 MV x-ray beam and a optimal beam spoiler when treating a patient, a similer build-up dose with a 6 MV photon beam could be achieved, while maintaining a certain amount of skin spring. But it was provided higher surface dose under SSS of less than 5 cm, the spoiler thickness of more than 1.8 cm or more, and larger field size than $20{\times}20cm^2$ provided higher surface dose like bolus and obliterated the spin-sparing effect. the effects of the beam spoiler on beam profile was reduced with increasing depths. Conclusion: The lucite spoiler allowed using of a 10 MV photon beam for the radiation treatment of head and neck caner by yielding secondary scattered electron on the surface. The dose at superficial depth was increased and the depth of maximum dose was moved to near the skin surface. Spoiling the 10 MV x-ray beam resulted in treatment plans that maintained dose homogeneity without the consequence of increased skin reaction or treat volume underdose for regions near the skin surface. In this, the optimal spoiler thickeness of 1.2 cm and 1.8 cm were found at SSS of 7 cm for $10{\times}10cm^2$ field. The surface doses were measured 60% and 64% respectively. In addition, It showed so optimal that 94% and 94% at the depth of 0.4 cm and dmax respectively.

  • PDF

Comparison of relative fitness between zirconia single coping and 3-unit fixed partial dentures (FPDs) manufactured by dental CAD/CAM system (치과 캐드/캠 시스템으로 제작된 지르코니아 single 코핑과 3-unit 구조물의 상대적 적합도 비교)

  • Lee, Wan-Sun;Park, Jong-Kyoung;Kim, Wook-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.16-22
    • /
    • 2014
  • Purpose: The purpose of this study was to assess the marginal and mesial fitness of zirconia single copings and 3-unit fixed partial dentures (FPDs) manufactured with an identical model. Materials and Methods: An epoxy model in which the maxillary right 2nd premolar is lost and maxillary 1st premolar and 2nd molar are formed as abutments was manufactured and scanned by using a laser scanner. A ten units of zirconia single copings were manufactured for maxillary 1st premolar and 2nd molar, respectively and the same number of 3-unit FPDs were manufactured. For the measurements of fitness, the manufactured silicone replicas were divided into four parts and the fitness were measured by digital microscope at measurement points (P1, P2, P3, P4 and P5) of each plane. The measured gaps were classified into three categories: marginal gap (MG, P1), axial gap (AG, average of P2 and P3), occlusal gap (OG, average of P4 and P5). Results: The ranges of MG, AG and OG for single copings were 18.47 - 40.54 ${\mu}m$, 39.73 - 73.61 ${\mu}m$ and 116.90 - 134.69 ${\mu}m$, respectively. The ranges of MG, AG and OG for 3-unit FPDs were 45.95 - 87.44 ${\mu}m$, 23.78 - 57.00 ${\mu}m$ and 99.89 - 131.06 ${\mu}m$, respectively. Conclusion: The result of the study shows that the MGs for 3-unit FPDs were higher than those of single copings, though they are within the range of clinical acceptance, indicating that the use of more homogeneous zirconia block and modification of sintering processes are needed to ensure the prevention of increase of gap in 3-unit FPDs.

Research on the Need Assessment Tool for the Korean Elderly at Home Focused on their Desires Based (한국 재가노인의 욕구중심 사정도구 개발에 관한 연구)

  • Kirn, Young sook;Jung, Kook in;Park, So rah
    • 한국노년학
    • /
    • v.27 no.2
    • /
    • pp.459-472
    • /
    • 2007
  • This research has its purpose of developing a tool to assess the needs of the Korean elderly at home population and to provide adequate services by evaluating their physical, psychological, and socio-environmental aspects. This developed tool is composed of two hundred questions and has the advantage of combined physical, psychological and social environmental situation assessment of the elderly at home. The tool also contains not only the objective view of the professionals, but also the subjective appeals of the elderly at home population so that it can reflect their substantial desires. The assessment tool was developed over 21 months from July, 2004 to March, 2006 and this period can be divided into three different stages. In the first stage, collecting of questions for the desire-focused assessment of the elderly by literature investigation and researching foreign source materials was carried out, and this ultimately developed assessment tool was applied to the long-term care insurance pilot project in the second stage. In this process, we revised some insufficiencies of this tool after we applied to elderly of 250 from the pilot project and other 200 elderly from this research team. For the last stage, the tool was completed by using inquiries of the focused group and the group of professionals to ensure its reliability and validity. In the process of developing the tool, the total of 200 questions under 13 subcategories was selected. The 13 subcategories are basic information, subjective appeals, information of the main helper, use of services, house environment, condition of health, condition of rehabilitation, daily living(ADL, IADL, defecation, assistance), social maintenance, behavioral disability, medical health, living habits, and strength. This tool is on the purpose to assess thoroughly the desires that the elderly at home population has and to provide the best service they need.