• Title/Summary/Keyword: Pumping efficiency

Search Result 246, Processing Time 0.033 seconds

Assessment of Water Management Efficiencies for Irrigation Pumping Stations in the Han River and Nakdong River Basins (한강 및 낙동강 유역의 양수장 지구 물관리효율 평가)

  • Kim, Hyeon-Jun;Kim, Chul-Gyum;kim, Sung
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.1
    • /
    • pp.23-32
    • /
    • 2003
  • The objective of this study is assessing water management efficiency using water withdrawals from rivers and water requirements for paddies. The water management efficiency was defined by the ratio of water requirements and water withdrawals. Water withdrawals were estimated using the operating times and pumping capacity of the pumping stations from 1992 to 1999 in the Han River and Nakdong River basins. Water requirements were estimated by adding the evapotranspiration of the crops and infiltrations in the irrigated area. Evapotranspiration from the paddies was calculated by the FAO modified Penman method with observed daily weather data. The monthly water management efficiency was analyzed for each pumping stations and the district offices of KARICO (Korea Agricultural and Rural Infrastructure Corporation). The efficiencies of 59 pumping stations in the Han River basin varied from 19% to 135%, and the average was 61%. The efficiencies of 146 pumping stations in the Nakdong River basin ranged from 17% to 190%, and the average was 72%. There were no good correlations between the water management efficiency and pump capacity or irrigated area, it showed that the water management efficiency was affected by the traditional water management practices rather than the scale of irrigation district.

Effect of Distilled Water Supply Method on Performance of PEMWE Typed Hydrogen Generators for Inhalation (흡입용 PEMWE형 수소 발생기에서 증류수 공급 방법이 성능에 미치는 영향)

  • In-Soo, You;Hyunwoo, Bae;Joon Hyun, Kim;Jaeyong, Sung
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.117-127
    • /
    • 2022
  • The present study has investigated the performance of hydrogen gas generators for inhalation purposes based on polyelectrolyte membrane water electrolysis (PEMWE). The system applied two watering methods. One is pumped water (pumping system) and the other is gravity-fed water without a pump (non-pumping system). The cell efficiencies were compared by measuring the cell voltage and temperature in the hydrogen gas generator, respectively. The results show that the cell voltage and temperature increase with the cell current. The cell temperature is lower in the pumping system than that in the non-pumping system at a given cell current. Even though the amount of hydrogen production is the same regardless of the pumping system, the cell efficiency of the hydrogen gas generator in the non-pumping system is better than that in the pumping system.

Pumping Efficiency of the Small Size Tube Well (소형관정의 양수효율)

  • Jeoung, Jae-Hun;Park, Seung-Ki;Kang, Sung-Min;Lee, Seung-Kee
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.221-224
    • /
    • 2002
  • The analysis of characteristics of pumping in the small tube well for agriculture were surveyed. Study area was located at the Galsinri in Yesangun near the yedang reservoir. Agricultural electricity using rates for pumping, ground water level and volume of pumping was monitored every week. Pump working ratio and pump efficiency during period of transplanting of rice showed 48.5%, 58.4% respectively.

  • PDF

Development of concrete pumping technology for construction of high-rise building using electromagnetic field (전자기장을 활용한 초고층 건축물 콘크리트 압송기술개발)

  • Kim, Woo-Jea;Kwon, Seung-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.4-5
    • /
    • 2018
  • Recently, high-strength concrete used for shortening the construction time of high-rise building construction, Concrete pumping technology is emerging as the core technology of high-rise buildings. In this paper, we have started to study the use of electromagnetic field as a method to increase the efficiency of the lubricating layer between the inside of the pipe and concrete, which has been established as the most important factor determining the pumping performance. The pumping performance improvement effect of concrete strength was verified and basic research was carried out to utilize it as a method to increase the efficiency of pumping in field application. In the related work, the effect of the electromagnetic field was verified by conducting a mock-up performance evaluation (horizontal 300 m) of the pumping force by the concrete strength.

  • PDF

Analysis of Irrigation Efficiency and Pattern in Galshin Pumping District (갈신양수장 관개지구의 관개효율과 관개패턴분석)

  • Ryu, Bumhee;Park, Seungki
    • Journal of Korean Society of Rural Planning
    • /
    • v.26 no.3
    • /
    • pp.91-102
    • /
    • 2020
  • The purpose of study was analyze the pumping characteristics, Irrigation Efficiency(IE), and irrigation pattern by period of rice growing stage with based on the performance of design irrigation water requirement and operational Galshin Pumping(GP) station in GP irrigation district constructed under rural water development project master plan. GP station was located in Yedang reservoir, Yesan-gun, Chungcheongnam-do and has been supplying irrigation water since 2006. The research data are the Irrigation Water Requirement(IWR) and the Pumping Water Amount(PWA) from 2006 to 2015 at the GP station, which is the supplied amount. The IWR were calculated using the Blaney-Criddle formula of the HOMWRS program, Hydrological Operation Model for Water Resource System, developed by Korea Rural Community Corporation. The Blaney-Criddle formula was used to calculate design irrigation water requirement of Galshin rural water development project master plan. During 2006-2015, the study period, the annual average IWR is 763.2(±149.1)mm, the annual PWA of the GP station is 397.4mm to 1,056.9mm, and those average annual PWA is 643.4(±208.4)mm. The annual IE of GP station 96.5% to 169.0%, and the average annual IE is 124.3%, which is higher than the research results conducted in other pumping stations. Analyzing the irrigation patterns of the GP irrigation district, the IWR Ratio per 10days(IWRR) and the PWA Ratio per 10days(PWAR) of the G P station were obtained. The IWRR is the percentage of IWR for each 10 days of a month to total IWR per year, and the PWAR is the percentage of PWA for each 10 days of a month to total PWA per year. The Kolmogorov- Smirnov(K-S) test results of IWRR and PWAR showed the characteristics classification by rice growing stage and stable normal distribution characteristics. Average IWRR(AIWRR) and Average PWAR(APWAR) are presented as irrigation patterns. Irrigation pattern analysis will be able to standardize comparison, analysis and probability calculation of the pumping station characteristics of different pumping stations and apply to objective evaluation of the pumping station district.

해안 지역 농촌지하수 시스템분석 (화성시 매향리 일대)

  • 김윤영;이기철;정형재;박종철
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.422-425
    • /
    • 2003
  • Many pumping station of Maehang-ri of Hwasung city are established for irrigation water supply, and brine permeation phenomenon is happening thereby. Proposed optimum pumping fluid amount conclusion model that use tidal efficiency and Ghyben-Hertzberg theory so that brine does not permeate in pumping station hereupon and applied this in study area.

  • PDF

Estimation of water efficiency for the irrigation pumping area in the Han River basin (한강유역의 농업용수 양수장 물관리 효율 산정(관개배수 \circled1))

  • Kim, Chul-Gyum;Kim, Hyeon-Jun;Kim, Sung
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.132-137
    • /
    • 2000
  • A term, $\ulcorner$Water Efficiency$\lrcorner$ was defined as a measure for the effective water management improvements in agriculture. To estimate the water efficiency, 7-year (1993∼1999) historical pumping records were collected from 59 pumping stations and water requirements of paddy fields for each station were estimated in the Han River basin. The water efficiency was estimated monthly and annually, and the assessment of the results was performed for each station and the associated branch offices of KARICO.

  • PDF

A VPP Generator Design for a Low Voltage DRAM (저전압 DRAM용 VPP Generator 설계)

  • Kim, Tae-Hoon;Lee, Jae-Hyung;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.776-780
    • /
    • 2007
  • In this paper, the charge pump circuit of a VPP generator for a low voltage DRAM is newly proposed. The proposed charge pump is a 2-stage cross coupled charge pump circuit. The charge transfer efficiency is improved, and Distributed Clock Inverter is located in each charge pump stage to reduce clock period so that the pumping current is increased. In addition, the precharge circuit is located at Gate node of charge transfer transistor to solve the problem which is that the Gate node is maintained high voltage because the boosted charge can't discharge, so device reliability is decreased. The simulation result is that pumping current, pumping efficiency and power efficiency is improved. The layout of the proposed VPP generator is designed using $0.18{\mu}m$ Triple-Well process.

  • PDF

Characteristics of Pumping in Small Tube Wells for Agricultural (농업용 소형 관정의 양수 특성)

  • Jung, Jae-Hun;Hwang, Moo-Suk;Park, Seung-Ki;Lee, Seung-Ki
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.106-109
    • /
    • 2001
  • The analysis of characteristics of pumping in the small tube well for agriculture were surveyed. Study area was located at the Galsinri in Yesangun near the yedang reservoir. Agricultural electricity using rates for pumping, ground water level and volume of pumping was monitored every week. Pump working ratio and pump efficiency during period of transplanting of rice showed 48.9%, 62.7% respectively.

  • PDF