• 제목/요약/키워드: Pulsed Current

검색결과 494건 처리시간 0.033초

전차선로 해빙시스템의 온도특성 (Temperature Analysis of the De-icing System for Overhead Contact Wire)

  • 고병훈;박영;정호성;권삼영;박현준
    • 한국전기전자재료학회논문지
    • /
    • 제20권11호
    • /
    • pp.1004-1008
    • /
    • 2007
  • The ice coats are built on 25 kV overhead contact wire when the temperature is lower than $0^{\circ}C$. It generates shockwaves at the mechanical interface of the collecting strips of the pantograph and the contact wire. The de-icing processes should be performed to avoid shockwaves which are generated by a pulsed high-voltage arc discharge. This paper presents temperature analysis of the de-icing effects which could be applied to the overhead contact wire of railways using Joule heat. The results show that 350 A is the proper current for $0^{\circ}C$ conductor according to environmental condition such as velocity of air stream, ambient temperature and moisture.

전자빔 다이오드 구조개선에 의한 대전력 후진파발진기의 구현 (Implementation of a High Power Backward Wave Oscillator on Electron Beam Diode Structure Improvement)

  • 김원섭
    • 한국전기전자재료학회논문지
    • /
    • 제22권10호
    • /
    • pp.897-903
    • /
    • 2009
  • We have designed the backward wave oscillator. A power-pulsed generator oscillated at 24 GHz has higher frequency than current one. It is very inportant to prevent microwave from going into the beam diode, since intence microwave will harmfully affect beam generation. Due to the axial mode operation, there exist a critial value of beam energy for the oscillation. By changing the condition at the SWS end, an enhanced performance of the K-band oversized BWO is observed in a low magnetic field region about 0.8T.

A Design and Implement of the Medical Nd:YAG Laser Firmware under in ZCC method

  • Kim, Whi-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.40.3-40
    • /
    • 2001
  • The pulsed Nd:YAG laser is the most commonly used type of solid-state laser in many fields. In material processing and medical treatment, the power density control of a laser beam Considered to be significant, which depends on the flashlamp current pulse width and pulse repetition rate. For general laser power supply to control the laser power density, the secondary of the power transformer is connected to the rectifier and filter capacitor. The output of a rectifier is applied to a switching element in the secondary of the transformer. So power supply is complicated and the loss of switching is considerably. In addition, according to increasing pulse repetition rate, charged energy of energy-storage capacitor bank is not transferred sufficiently to flashlamp, and laser output efficiency decreases. In this study, we have ...

  • PDF

Two-dimensional Laser Drilling Using the Superposition of Orthogonally Polarized Images from Two Computer-generated Holograms

  • Lee, Hwihyeong;Cha, Seongwoo;Ahn, Hee Kyung;Kong, Hong Jin
    • Current Optics and Photonics
    • /
    • 제3권5호
    • /
    • pp.451-457
    • /
    • 2019
  • Laser processing using holograms can greatly improve processing speed, by spatially distributing the laser energy on the target material. However, it is difficult to reconstruct an image with arrays of closely spaced spots for laser processing, because the specklelike interference pattern prevents the spots from getting close to each other. To resolve this problem, a line target was divided in two, reconstructed with orthogonally polarized beams, and then superposed. Their optical reconstruction was performed by computer-generated holograms and a pulsed laser. With this method, we performed two-dimensional (2D) laser drilling of polyimide film, with a kerf width of $20{\mu}m$ and a total processing length of 20 mm.

Optical Stimulation and Pacing of the Embryonic Chicken Heart via Thulium Laser Irradiation

  • Chung, Hong;Chung, Euiheon
    • Current Optics and Photonics
    • /
    • 제3권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Optical stimulation provides a promising alternative to electrical stimulation to selectively modulate tissue. However, developing noninvasive techniques to directly stimulate excitable tissue without introducing genetic modifications and minimizing cellular stress remains an ongoing challenge. Infrared (IR) light has been used to achieve optical pacing for electrophysiological studies in embryonic quail and mammalian hearts. Here, we demonstrate optical stimulation and pacing of the embryonic chicken heart using a pulsed infrared thulium laser with a wavelength of 1927 nm. By recording stereomicroscope outputs and quantifying heart rates and movements through video processing, we found that heart rate increases instantly following irradiation with a large spot size and high radiant exposure. Targeting the atrium using a smaller spot size and lower radiant exposure achieved pacing, as the heart rate synchronized with the laser to 2 Hz. This study demonstrates the viability of using the 1927 nm thulium laser for cardiac stimulation and optical pacing, expanding the optical parameters and IR lasers that can be used to modulate cardiac dynamics.

PLS-II 용 반도체 스위치 기반 키커 펄스 모듈레이터 설계 및 제작 (Design and Implementation of Solid-State Kicker Modulator for PLS-II)

  • 안석호;공형섭;박웅화;이병준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.307-308
    • /
    • 2019
  • The Pohang Light Source (PLS) - II is a 3 GeV third-generation synchrotron radiation facility. To inject electron beam from LINAC, a kicker modulator system and kicker magnets are installed in the PLS-II storage ring tunnel. The injected beam then falls into the storage ring beam dynamic aperture. This paper describes the design and implementation of the solid-state kicker modulator for PLS-II. The solid-state kicker modulator is consisted of high voltage solid state switch stacks. the technical considerations of the solid-state switch stacking for kicker modulator is discussed. The achieved capability of the solid-state kicker modulator demonstrates that is fulfills the design requirement of providing half-sine pulsed current of 10kA (peak), 6us (Base-width), with jitter < 2ns (Standard deviation). simulation and experimental results are presented to demonstrate the performance of the solid-state kicker modulator.

  • PDF

의료용 선형가속기 응용분야를 위한 고전압 펄스 전원 모듈레이터 (High voltage Pulsed Power modulator for medical LINAC applications)

  • 조현빈;송승호;이승희;박수미;장성록;류홍제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.101-103
    • /
    • 2018
  • This paper describes -40kV high voltage solid state pulse power modulator (SSPPM) for driving a magnetron, which is used as a RF power source of LINAC for cancer treatment systems. In case of the medical LINAC, small size and light weight are required. The SSPPM is 92 liters in size and weighs 50 kg. In this paper, S-band 2.6 MW magnetron load experiment is conducted and impedance matching was applied to obtain a smooth output current. Finally, the experimental results is discussed and the reliability of SSPPM is verified.

  • PDF

Compact, Wavelength-selectable, Energy-ratio Variable Nd:YAG Laser at Mid-ultraviolet for Chemical Warfare Agent Detection

  • Kim, Jae-Ihn;Cho, Ki Ho;Lee, Jae-Hwan;Ha, Yeon-Chul
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.243-247
    • /
    • 2019
  • We have developed a compact, wavelength-selectable, Q-switched Nd:YAG laser at mid ultraviolet for chemical warfare agent detection. The fundamental wave at 1064 nm is delivered by a pulsed solid state laser incorporating with a square-type Nd:YAG rod in a resonator closed by two crossed Porro prisms for environmental reliability. The output energy at 213 nm ($5{\omega}$) and 266 nm ($4{\omega}$) by ${\chi}^{(2)}$ process in the sequentially disposed BBO crystals are measured to be 6.8 mJ and 15.1 mJ, respectively. The output wavelength is selected for $5{\omega}$ and $4{\omega}$ by a motorized wavelength switch. The energy ratio of the $5{\omega}$ to the $4{\omega}$ is varied from 0.05 to 0.85 by controlling the phase matching temperature of the nonlinear crystal for sum-frequency generation without change of the output pulse parameters.

Evanescent-field Q-switched Yb:YAG Channel Waveguide Lasers with Single- and Double-pass Pumping

  • Bae, Ji Eun;Choi, Sun Young;Krankel, Christian;Hasse, Kore;Rotermund, Fabian
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.180-185
    • /
    • 2021
  • A femtosecond-laser inscribed Yb:YAG surface channel waveguide (WG) laser with single-walled carbon nanotubes deposited on the top surface of the WG was passively Q-switched by evanescent field interaction. Q-switched operation of the 14-mm-long compact Yb:YAG WG laser was achieved near 1031 nm with two different pumping schemes (single- and double-pass pumping) with an output coupling transmission of 91%. The Q-switched pulse characteristics depending on the absorbed pump power were investigated for both pumping geometries and analyzed in detail based on theoretical modeling. The best performances (energy/pulse duration) for each configuration were 204.4 nJ/75 ns at a repetition rate of 1.87 MHz, and 201.1 nJ/81 ns at 1.75 MHz for single- and double-pass pumping, respectively.

Autofluorescence Loss in Photobleaching for Human Dentin ex vivo

  • Lee, Seunghwan Goldmund;Kim, Minwoo;Jeong, Sunghee;Hwang, Jaejoon;Kim, Jisu;Gourrier, Aurelien;Vial, Jean Claude;Kyhm, Kwangseuk
    • Current Optics and Photonics
    • /
    • 제6권1호
    • /
    • pp.86-91
    • /
    • 2022
  • Two-photon fluorescence microscopy was performed on the enamel-dentin junction area of a human tooth using a femtosecond pulsed laser. We obtained a clear image contrast between the bright dentin and dark tubules with the autofluorescence generated from the endogenous fluorophores in dentin. The autofluorescence shows a broad spectrum due to complex cross links between dentinal collagens, which extend from blue to orange wavelengths (470-590 nm), but a gradual autofluorescence loss in photobleaching was observed for a long-term exposure under strong excitation. For increasing excitation power, we found that two-step decay becomes significant in the spectrally integrated autofluorescence.