• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.032 seconds

PULSE OXIMETER AS A DIAGNOSTIC TEST OF PULP VITALITY (Pulse Oximeter를 이용한 치수생활력측정)

  • Koo, Bon-Kyung;Lee, Jae-Ho;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.103-107
    • /
    • 2000
  • Traditionally, EPT and thermal tests were used as diagnostic methods for pulp vitality test. The thermal and electrical stimulation tests are the methods to determine the vitality of a tooth based on its neuronal response. These have certain limitations, one of them is the difficulty of approaching the correct result in case of treatment of children. The reason is management problem caused by the unpleasant stimulation. Also, the response from patients are not objective, and false positive or false negative could be happened. Recently, laser doppler flowmetry and pulse oximeter which evaluate vascular integrity are introduced in an effort of overcoming to limitation of traditional methods. The principle of pulse oximeter is to and out level of oxygen saturation by ratio of the two pulses between emitted light and detected light penetrating them to the termination of body, such as ears or fingers. From this point of view, it can be applied to a tooth to determine its vitality. The objective of this study lies mainly on varifying pulse oximeter as a method of determining tooth vitality and providing basic data of its clinical implementation. The result of the research showed that level of oxygen saturation in vital teeth was average of 96.3% and 0.0% in pulpless teeth. As a comprehensive result, pulse oximeter could be an useful diagnostic equipment in determining of tooth vitality.

  • PDF

Retrospective Clinical Study of Pulse Wave Characteristics According to Healthy State Level in Sasang Constitution (사상체질 완실무병(完實無病) 수준에 따른 맥파(脈波) 특성의 후향적 임상 연구)

  • Su-Hyun Kim;Jun-Yong Park;Ho-In Kim;Jong-Cheon Joo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.35 no.4
    • /
    • pp.1-9
    • /
    • 2023
  • Objectives This study is designed to examine the relationship between healthy state (完實無病) of Sasang constitution and pulse wave (脈波). Methods The subjects were 100 patients who were diagnosed with Sasang constitution and underwent pulse analyzer test. The status of urination, defecation, perspiration, and digestion was classified as good, intermediate, and poor. The power, depth, speed, and roughness of pulse waves (脈波) were analyzed. Results Patients with poor digestion had relatively powerless pulse wave (無力脈). Soeumin patients had a higher rate of poor digestion compared to other constitutions. Soyangin patients had a higher rate of poor perspiration compared to other constitutions. Soyangin with poor defecation had relatively choppy pulse wave (澁脈), and poor perspiraton had relatively slippery (滑脈). Soeumin patients with poor digestion had relatively powerless pulse wave (無力脈). Conclusions The pulse wave of poor healthy state (完實無病) is an expression of a pathological syndromes (病證) caused by lack of or damage to healthy energy (保命之主). It was concluded that the pulse analyzer can be used to evaluate healthy state (完實無病).

Method for Determining the Deficient and Solid Pulse with a New Pulse Wave Parameter (새로운 맥상 파라메터를 이용한 허실맥 판단 방법)

  • Kim, Sung-Hun;Kim, Jae-Uk;Jeon, Young-Ju;Kim, Keun-Ho;Kim, Jong-Yoel
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.1
    • /
    • pp.42-47
    • /
    • 2010
  • The pulse diagnosis is an important method in Oriental Medicine. Recently, there have been continuous attempts to replace the finger palpation by Oriental medical doctors (OMDs) by more objective tools based on machines, e.g., pulse analyzers. To improve the performance of the pulse analyzers, both the machine-appropriate interpretations for the pulse images appeared in the literature and the improvement in the repeatability and reproducibility of the measurement sensors are to be developed. As an attempt towards the transformation of the pulse images in terms of machine-appropriate language, in this work, we suggest an upgraded algorithm for the solid/deficient pulses, which are the two representative pulse images informing us how strong the pulse pressure is. It has been argued that one could determine the solid/deficient pulses by the maximum pulse pressure from pulse analyzers. However, by a clinical test, we found that the maximum pulse pressure alone is not sufficient to determine the solid/deficient pulses. In addition to the maximum pulse pressure, the mean pulse pressure averaged over for five different hold-down pressures(3-D MAC) is needed to improve the agreement with the OMD's decision for the solid/deficient pulse. We found that, among the data diagnosed with having either the solid pulse or deficient pulse by OMDs, the novel algorithm showed 86.0% diagnosis rate and 81.6% concordance rate.

Experiments on Development A Pulse-Gun Pressure-Wave Inducing Device for Stability Rating Test Technique (연소안정성 평가시험 기법을 위한 펄스건 압력파 유도장치 개발 실험)

  • Lee, Kwang-Jin;Kim, Hong-Jip;Seo, Seong-Hyeon;Moon, Il-Yoon;Kim, Hyung-Mo;Lee, Soo-Yong;Ko, Young-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.99-106
    • /
    • 2005
  • The SRT(stability rating test) technique, which is indispensable for the development of a LRE(liquid rocket engine), essentially requires a development of a combustion test sequence as well as artificial perturbation devices. For the development of an indigenous SRT technique, several combustion tests of sub-scale LRE were performed to search a proper combustion test sequence. At first, a pressure-wave inducing device which is used for adapting pulse gun was designed and a cooling gas supply system for the pressure-wave inducing device was set up to prevent a malfunction of pulse gun. Through the several combustion tests which included cooling procedure of a pressure-wave inducing device, a proper combustion test sequence was found out. It did not make any significant disturbance at normal combustion process. Finally, an indigenous SRT technique has been developed successfully.

Performance Test of Domestic Glass Fabric by varying cleaning conditions in a Pulse-Jet Cleaned Fabric Filter (충격기류 탈진방식 여과포집진장치에서 탈진조건 변화에 따른 국산유리섬유여과포의 성능시험)

  • 박영옥;구철오;임정환;김영성;손재익
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.3
    • /
    • pp.183-190
    • /
    • 1994
  • Performance of domestic glass fabrics was tested in a Pulse- jet cleaned fabric filter under simulated coal combustion. Pulse Pressure were 2.5, 4.0kgf/$\textrm{cm}^2$ and pulse air nozzle diameter were 4.0, 6.0mm Pressure drop and penetration turned out to be low at small pulse air nozzle diameter and low pulse air pressure. Fractional penetration through the dust cake and fabric at face velocity of 1.7m/min was higher than that at face velocity of 1.0m/min. As a consequense, the performance of domestic glass fabrics was better with face velocity of less than 1.0m/min, pulse air pressure of 2.5 kgf/$\textrm{cm}^2$ and pusle air nozzle diameter of 4.0mm.

  • PDF

FUNDAMENTAL PERFORMANCE OF IMAGE CODING SCHEMES BASED ON MULTIPULSE MODEL

  • Kashiwagi, Takashi;Kobayashi, Daisuke;Koda, Hiromu
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.825-829
    • /
    • 2009
  • In this paper, we examine the fundamental performance of image coding schemes based on multipulse model. First, we introduce several kinds of pulse search methods (i.e., correlation method, pulse overlap search method and pulse amplitude optimization method) for the model. These pulse search methods are derived from auto-correlation function of impulse responses and cross-correlation function between host signals and impulse responses. Next, we explain the basic procedure of multipulse image coding scheme, which uses the above pulse search methods in order to encode the high frequency component of an original image. Finally, by means of computer simulation for some test images, we examine the PSNR(Peak Signal-to-Noise Ratio) and computational complexity of these methods.

  • PDF

Effect of Auxiliary Address Pulse on Face-to-face Sustain Electrode Structure in AC-PDP

  • Kim, Bo-Sung;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.605-608
    • /
    • 2007
  • The discharge characteristics of the face-to-face sustain electrode structure employing auxiliary address pulse are investigated under a sustain driving frequency of 20 kHz and various auxiliary address pulse widths (500 ns, $1{\mu}s$, $2\;{\mu}s$) in the 6-in. test panel (42-in. Full HD grade) with a pressure of 450 Torr and a 4 % Xe-content. The luminance and the luminous efficiency at the auxiliary address pulse width of 500 ns are improved more than these of $1\;{\mu}s$ and $2\;{\mu}s$. At the auxiliary address pulse width of 500 ns, the luminous efficiency shows about 0.96 lm/W at the auxiliary pulse of 90 V and the sustain voltage of 260 V.

  • PDF

Pulse Multiplication in Autotransformer Based AC-DC Converters using a Zigzag Connection

  • Singh, Bhim;Gairola, Sanjay
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.191-202
    • /
    • 2007
  • This paper deals with pulse multiplication in zigzag connected autotransformer based 12-pulse AC-DC converters feeding vector controlled induction motor drives (VCIMD) for improving the power quality at the point of common coupling (PCC) without using a Zero-Sequence-Blocking-Transformer (ZSBT). The proposed 24-pulse AC-DC converter is based on the principle of DC ripple re-injection technique for pulse multiplication and harmonic mitigation. The design of the autotransformer is carried out for the proposed AC-DC converter and the effect of load variation on VCIMD is also studied to demonstrate the effectiveness of the proposed AC-DC converter. Test results from a laboratory developed prototype, along with simulated results, are presented to validate the design and model of the proposed 24-pulse AC-DC converter.

A Study on the Welding Behavior of A3003 Aluminium Alloy Thin Sheet by Nd : YAG Laser Beam (박판 A3003 Al합금의 Nd : YAG 레이저빔 용접에 관한 연구)

  • 허인석;김병철;김도훈;김진수;이한용
    • Laser Solutions
    • /
    • v.4 no.1
    • /
    • pp.29-38
    • /
    • 2001
  • This work was carried out to investigate the welding behavior of thin A3003 Al alloy sheets by Nd : YAG laser beam. Considering bead shape and mechanical properties, the laser pulse shapes selected were two kinds of 2-division and 3-division by varying power level and pulse duration. In order to obtain optimum conditions, the factorial design method and central composite design method were applied. Tensile test, optical microscopy, micro hardness test and TEM analysis were performed. Due to the annealing caused by thermal effect during laser welding, precipitates were coarsended. The HAZ was softened and failed during tensile test. The hardness of HAZ was lower than that of base metal, since the heat input relieved the work hardening effect and caused grain growth.

  • PDF

Winding Deformation Measurement using Low-voltage Impulse Tester in Transformers (변압기에서 저압충격시험기를 이용한 권선변형 측정)

  • Cho, Kook-Hee;Kang, Dong-Sik;Kim, Kwang-Hwa;Kweon, Dong-Jin;Yoon, Jin-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1737-1739
    • /
    • 1997
  • We describe the characteristic of LVI test system and methods to detect the deformation of windings in the power transformers. As the front rise time of recurrent-surge generator pulse less than 1000ns and the peak value of pulse is about 500V, we have the good results of detecting winding deformation in the LVI test of transformer. And we discuss the application of LVI test method and the condition of RSG pulse through results of in one and three pole transformers under Lab. tests.

  • PDF