• Title/Summary/Keyword: Pulse sequence

Search Result 308, Processing Time 0.023 seconds

A Study on A Multi-Pulse Linear Predictive Filtering And Likelihood Ratio Test with Adaptive Threshold (멀티 펄스에 의한 선형 예측 필터링과 적응 임계값을 갖는 LRT의 연구)

  • Lee, Ki-Yong;Lee, Joo-Hun;Song, Iick-Ho;Ann, Sou-Guil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.20-29
    • /
    • 1991
  • A fundamental assumption in conventional linear predictive coding (LPC) analysis procedure is that the input to an all-pole vocal tract filter is white process. In the case of periodic inputs, however, a pitch bias error is introduced into the conventional LP coefficient. Multi-pulse (MP) LP analysis can reduce this bias, provided that an estimate of the excitation is available. Since the prediction error of conventional LP analysis can be modeled as the sum of an MP excitation sequence and a random noise sequence, we can view extracting MP sequences from the prediction error as a classical detection and estimation problem. In this paper, we propose an algorithm in which the locations and amplitudes of the MP sequences are first obtained by applying a likelihood ratio test (LRT) to the prediction error, and LP coefficients free of pitch bias are then obtained from the MP sequences. To verify the performance enhancement, we iterate the above procedure with adaptive threshold at each step.

  • PDF

Experimental Study of Chemical Shift Artifacts at 1.5T and 3.0T MRI using Gradient Echo Pulse Sequence (GE 펄스시퀀스을 이용한 1.5T와 3.0T MRI의 화학적 이동 인공물의 실험적 연구)

  • Cheol, Kweon Dae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.531-537
    • /
    • 2016
  • An experimental study was to use the parameter to determine the MRI artifact of chemical shift that occurs in water and fats. Scanning the image according to the encoding parameter and the bandwidth and change in 1.5T and 3.0T MRI to the SNR, we compared the CNR. In the image was confirmed that the occurrence of artefacts in the chemical shift of the water and oil. 3.0T more image artifacts in the 1.5T was confirmed that the relatively reduced. The width of the bandwidth it could be confirmed that according to the honeycombs artifacts decrease. Therefore, in order to reduce the artifacts in the MRI scan of the chemical shift runners weak field strength, is thought to be appropriate to widen the width of the bandwidth.

Improved Current Source Design to Measure Induced Magnetic Flux Density Distributions in MREIT

  • Oh Tong-In;Cho Young;Hwang Yeon-Kyung;Oh Suk-Hoon;Woo Eung-Je;Lee Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.30-37
    • /
    • 2006
  • Injecting currents into an electrically conducting subject, we may measure the induced magnetic flux density distributions using an MRI scanner. The measured data are utilized to reconstruct cross-sectional images of internal conductivity and current density distributions in Magnetic Resonance Electrical Impedance Tomography (MREIT). Injection currents are usually provided in a form of mono-polar or bi-polar pulses synchronized with an MR pulse sequence. Given an MRI scanner performing the MR phase imaging to extract the induced magnetic flux density data, the current source becomes one of the key parts determining the signal-to-noise ratio (SNR) of the measured data. Since this SNR is crucial in determining the quality of reconstructed MREIT images, special care must be given in the design and implementation of the current source. This paper describes a current source design for MREIT with features including interleaved current injection, arbitrary current waveform, electrode switching to discharge any stored charge from previous current injections, optical isolation from an MR spectrometer and PC, precise current injection timing control synchronized with any MR pulse sequence, and versatile PC control program. The performance of the current source was verified using a 3T MRI scanner and saline phantoms.

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

The Design of 32 Bit Microprocessor for Sequence Control Using FPGA (FPGA를 이용한 시퀀스 제어용 32비트 마이크로프로세서 설계)

  • Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.6
    • /
    • pp.431-441
    • /
    • 2003
  • This paper presents the design of 32 bit microprocessor for a sequence control using a field programmable gate array(FPGA). The microprocessor was designed by a VHDL with top down method, the program memory was separated from the data memory for high speed execution of sequence instructions. Therefore it was possible that sequence instructions could be operated at the same time during the instruction fetch cycle. In order to reduce the instruction decoding time and the interface time of the data memory interface, an instruction code size was implemented by 32 bits. And the real time debug operation was implemented for easeful debugging the designed processor with a single step run, PC break point run, data memory break point run. Also in this designed microprocessor, pulse instructions, step controllers, master controllers, BM and BCD type arithmetic instructions, barrel shift instructions were implemented for sequence logic control. The FPGA was synthesized under a Xilinx's Foundation 4.2i Project Manager using a V600EHQ240 which contains 600,000 gates. Finally simulation and experiment were successfully performed respectively. For showing good performance, the designed microprocessor for the sequence logic control was compared with the H8S/2148 microprocessor which contained many bit instructions for sequence logic control. The designed processor for the sequence logic showed good performance.

In Vitro Imaging of MRI and Ultrasound for Gastric Carcinoma (위암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Kil, Sung-Won;Jee, Keum-Nahn
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.178-187
    • /
    • 2008
  • Purpose : To evaluate and compare the diagnostic accuracy of MRI and ultrasound(US) for estimation of invasion depth of gastric carcinoma by correlation with histopathologic findings in vitro and to find out the best MR pulse sequence for detection and accurate delineation of tumor. Materials and Methods : Resected specimen of total or subtotal gastrectomy from 53 patients with gastric carcinoma were done of imaging studies of MRI and US. And US was examined by using high frequency linear transducer for tumor invasion depth by a radiologist. In each case, both imaging findings of MRI and US were evaluated independently for tumor detection and invasion depth by consensus of two radiologists and were compared the diagnostic accuracy between two imaging modalities according to the histopathologic findings. MR imaging with five MR pulse sequences, spin echo T1 and in- and out-of phase gradient echo T1 weighted images, FSE and SSFSE T2 weighted images, were performed. Five MR pulse sequences were evaluated and compared on the point of detection and accurate distinction of tumor from surrounding normal tissue. Results : In EGC, diagnostic accuracy of US(77%) was superior than that of MRI(59%) but no statistically significant difference was noted between two imaging modalities(p=0.096). In AGC, both imaging modalities of MRI and US showed relatively high diagnostic accuracy as 97% and 84% respectively. Diagnostic accuracy of MRI was statistically better than that of US at the significant level(p<0.001). The best MR pulse sequence among five in each specimen was FSE T2WI(75.5%, 40/53) in both EGC and AGC. In AGC, FSE T2WI showed excellent imaging quality by showing very high ratio (93.5%, 29/31) of accurate delineation of tumor. Conclusion : MRI and US show relatively high diagnostic accuracy in the evaluation of tumor invasion depth of resected specimen in AGC. The most excellent pulse sequence of MRI for the evaluation of tumor invasion depth is FSE T2WI on the point of detection and accurate delineation of tumor in both EGC and AGC.

  • PDF

On the Performance Enhancements of VC Merging-capable Scheduler for MPLS Routers by Sequence Skipping Method (Sequence Skipping 방법을 이용한 MPLS 라우터의 VC 통합기능 스케쥴러의 성능 향상에 관한 연구)

  • Baek, Seung-Chan;Park, Do-Yong;Kim, Young-Beom
    • Journal of IKEEE
    • /
    • v.5 no.1 s.8
    • /
    • pp.111-120
    • /
    • 2001
  • VC merging involves distinguishing cells from an identical merged VC label. Various approaches have been proposed to help this identification process. However, most of them incur additional buffering, protocol overhead and/or variable delay. They make the provision of QoS difficult to achieve. So it was proposed a merge capable scheduler to support VC-merging (VCMS). However, in situations where all VCs are to be merged or the incoming traffic load is very low, it could happen that there are not enough non-merging cells to snoop. In this situation the scheduler uses special control cells to fill the empty time slots out. Too many control cells can cause high cell loss ratio and an additional packet transfer delay. To overcome the drawbacks, we propose a Sequence Skipping(SS) method where the sequencers skip the empty queues and insert SS cells. We show SS method is suitable for VC-merging and can reduce the cell loss ratio and the mean packet transfer delay through simulations.

  • PDF

Multi-slice Multi-echo Pulsed-gradient Spin-echo (MePGSE) Sequence for Diffusion Tensor Imaging MRI: A Preliminary Result (일회 영상으로 확산텐서 자기공명영상을 얻을 수 있는 다편-다에코 펄스 경사자장 스핀에코(MePGSE) 시퀀스의 초기 결과)

  • Jahng, Geon-Ho;Pickup, Stephen
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.65-72
    • /
    • 2007
  • An echo planar imaging (EPI)-based spin-echo sequence Is often used to obtain diffusion tensor imaging (DTI) data on most of the clinical MRI systems, However, this sequence is confounded with the susceptibility artifacts, especially on the temporal lobe in the human brain. Therefore, the objective of this study was to design a pulse sequence that relatively immunizes the susceptibility artifacts, but can map diffusion tensor components in a single-shot mode. A multi-slice multi-echo pulsed-gradient spin-echo (MePGSE) sequence with eight echoes wasdeveloped with selective refocusing pulses for all slices to map the full tensor. The first seven echoes in the train were diffusion-weighted allowing for the observation of diffusion in several different directions in a single experiment and the last echo was for crusher of the residual magnetization. All components of diffusion tensor were measured by a single shot experiment. The sequence was applied in diffusive phantoms. The preliminary experimental verification of the sequence was illustrated by measuring the apparent diffusion coefficient (ADC) for tap water and by measuring diffusion tensor components for watermelon. The ADC values in the series of the water phantom were reliable. The MePGSE sequence, therefore, may be useful in human brain studies.

  • PDF

Design of a Clock and Data Recovery Circuit Using the Multi-point Phase Detector (다중점 위상검출기를 이용한 클럭 및 데이터 복원회로 설계)

  • Yoo, Sun-Geon;Kim, Seok-Man;Kim, Doo-Hwan;Cho, Kyoung-Rok
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.72-80
    • /
    • 2010
  • The 1Gbps clock and data recovery (CDR) circuit using the proposed multi-point phase detector (PD) is presented. The proposed phase detector generates up/down signals comparing 3-point that is data transition point and clock rising/falling edge. The conventional PD uses the pulse width modulation (PWM) that controls the voltage controlled oscillator (VCO) using the width of a pulse period's multiple. However, the proposed PD uses the pulse number modulation (PNM) that regulates the VCO with the number of half clock cycle pulse. Therefore the proposed PD can controls VCO preciously and reduces the jitter. The CDR circuit is tested using 1Gbps $2^{31}-1$ pseudo random bit sequence (PRBS) input data. The designed CDR circuit shows that is capable of recovering clock and data at rates of 1Gbps. The recovered clock jitter is 7.36ps at 1GHz and the total power consumption is about 12mW. The proposed circuit is implemented using a 0.18um CMOS process under 1.8V supply.

A Study on PLL Speed Control System of DC Servo Motor for Mobile Robot Drive (자립형 이동로봇 구동을 위한 직류 서보전동기 PLL 속도제어 시스템에 관한 연구)

  • 홍순일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.60-69
    • /
    • 1993
  • The speed control associated with dc servo motors for direct-drive applications of mobile robot is considered in this study. Robot is moved by power wheeled steering of two dc servo motors mounted to it. In order to cooperate with micro-computer and to achieve the high-performance operation of dc servo motor, speed control system is composed of a digital Phase Locked Loop and H-type drive circuit. And the motor is driven by Pulse Width Modulations. In controlling PWM, it is modified to compose of H-type drive circuit with feedback diodes and switching transistor and design of control sequence so that it may show linear characteristics. As a result, speed characteristics of motor showed linear features. In order to get data on design of PLL control system, the parameters of 80[W[ motor & robot device is measured by simple software control. The PLL speed control system is schemed and designed by leaner drive circuit and measured parameters. A complete speed control system applied to 80[W] dc servo motor showed good linearity, stability and high response. Also, it is verified that the PLL speed control system has good compatibility as a mobile robot driver.

  • PDF