• Title/Summary/Keyword: Pulse interval

Search Result 249, Processing Time 0.03 seconds

MIG-WELDING OF MAGNESIUM ALLOYS WITH PARTICULAR CONSIDERATION OF DROP DETACHMENT

  • Wohlfahrt, H.;Rethmeier, M.;Wiesner, S.
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.94-100
    • /
    • 2002
  • During the last years, great progress has been made in the fields of welding power sources and filler materials for the MIG-welding of magnesium alloys. This advice resulted in a better welding process, md, therefore, in highly improved welding results. Furthermore the gap between short-circuiting- and spray-arc-trunsfer could be closed by the triggered short-circuiting- and the short-circuiting-arc with pulse overlay. A crucial contribution to the welding process is the energy input into the filler material. Many problems result from the physical properties of magnesium, for instance its narrow interval between melting point 600$^{\circ}C$ and vaporization point 1100$^{\circ}C$. The energy input into the filler material has to be regulated in such a way that the wire will melt but not vaporize. For th is reason, special characteristics of power sources hue been examined and optimized with the help of high-speed-photographs of the welding process with particular consideration of the drop detachment. An important improvement of the weld seam profile has been achieved by using filler material of only 1.2 mm in diameter. The experiments hue been made with 2.5 mm thick extruded profiles of AZ31 and AZ6l. The results of tensile testing showed strength values of 80 to 100% of the base metal. B ending angles up to 60$^{\circ}$ have been reached. The fatigue strength under reversed bending of the examined magnesium alloys after welding reaches 50% of the strength of the base metal. When the seam reinforcement is ground of the fatigue strength can be raised up to 75% of the base metal.

  • PDF

Reference values for pulp oxygen saturation as a diagnostic tool in endodontics: a systematic review and meta-analysis

  • Paula Lambert;Sergio Augusto Quevedo Miguens Jr;Caroline Solda;Juliana Tomaz Sganzerla;Leandro Azambuja Reichert;Carlos Estrela;Fernando Branco Barletta
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.48.1-48.11
    • /
    • 2020
  • Objectives: This systematic review aimed to identify mean oxygen saturation values (SpO2) using pulse oximetry in permanent maxillary anterior teeth. Materials and Methods: The MEDLINE, Scientific Electronic Library Online, Cochrane Central Register of Controlled Trials, EMBASE, and Literatura Latino Americana em Ciências da Saúde electronic databases were searched. Combinations and variations of "oximetry" AND "dental pulp test" were used as search terms. Studies reporting means and standard deviations of SpO2 values were included. Two reviewers independently extracted data following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist. Heterogeneity was assessed using the I2 statistic, and all analyses were performed using R software. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool and the Newcastle-Ottawa scale. Results: Of the 251 studies identified, 19 met the eligibility criteria and were included (total sample, 4,541 teeth). In the meta-analysis, the mean SpO2 values were 84.94% (95% confidence interval [CI], 84.85%-85.04%) for the central incisors, 89.29% (95% CI, 89.22%-89.35%) for the lateral incisors, and 89.20% (95% CI, 89.05%-89.34%) for the canines. The studies were predominantly low-quality due to the high risk of bias associated with the index test, unclear risk regarding patient selection, and concerns about outcome assessment. Conclusions: Although most studies were low-quality, the oxygen saturation levels in normal pulp could be established (minimum saturation, 77.52%). Despite the risk of bias of the included studies, the reference values reported herein are clinically relevant for assessments of changes in pulp status.

Respiratory complications during recovery from gastrointestinal endoscopies performed by gastroenterologists under moderate sedation

  • Inna Eidelman Pozin;Amir Zabida;Moshe Nadler;Guy Zahavi;Dina Orkin;Haim Berkenstadt
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.188-193
    • /
    • 2023
  • Background/Aims: Data on the incidence of adverse respiratory events during recovery from gastrointestinal endoscopy are limited. The aim of this study was to investigate the incidence of these complications. Methods: In this retrospective cohort study, data were obtained from the electronic records of 657 consecutive patients, who underwent gastroenterological procedures under sedation. Results: Pulse oximetry oxygen saturation (SpO2) <90% for <60 seconds occurred in 82 patients (12.5%), and in 11 patients (1.7%), SpO2 of <90% for >60 seconds occurred in 79 patients (12.0%) and in 14 patients (2.1%), and SpO2 <75% occurred in four patients (0.6%) and in no patients during the procedure and recovery period, respectively. No major complications were noted. The occurrence of desaturation during recovery was correlated with desaturation during the procedure (p<0.001). Higher American Society of Anesthesiologists score (odds ratio [OR], 1.867; 95% confidence interval [CI], 1.008-3.458), ischemic heart disease (OR, 1.815; 95% CI, 0.649-5.080), hypertension (OR, 1.289; 95% CI, 0.472-3.516), and diabetes mellitus (OR, 2.406; 95% CI, 0.950-6.095) increased the occurrence of desaturation during recovery. Conclusions: We found no major complications during recovery after balanced propofol-based sedation administered by a gastroenterologist-nurse team. Patients with the identified risk predictors must be monitored carefully.

3T MR Spin Echo T1 Weighted Image at Optimization of Flip Angle (3T MR 스핀에코 T1강조영상에서 적정의 숙임각)

  • Bae, Sung-Jin;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.177-182
    • /
    • 2009
  • Purpose : This study presents the optimization of flip angle (FA) to obtain higher contrast to noise ratio (CNR) and lower specific absorption rate (SAR). Materials and Method : T1-weighted images of the cerebrum of brain were obtained from 50$^\circ$ to 130$^\circ$ FA with 10$^\circ$ interval. Signal to noise ratios (SNRs) were calculated for white matter (WM), gray matter (GM), and background noise. The proper FA was analyzed by T-test statistics and Kruskal-wallis analysis using R1 = 1- exp ($\frac{-TR}{T1}$) and Ernst angle cos $\theta$ = exp ($\frac{-TR}{T1}$). Results : The SNR of WM at 130$^\circ$ FA is approximately 1.6 times higher than the SNR of WM at 50$^\circ$. The SNR of GM at 130$^\circ$ FA is approximately 1.9 times higher than the SNR of GM at 50$^\circ$. Although the SNRs of WM and GM showed similar trends with the change of FA values, the slowdown point of decrease after linear fitting were different. While the SNR of WM started decreasing at 120$^\circ$ FA, the SNR of GM started decreasing at less than 110$^\circ$. The highest SNRs of WM and GM were obtained at 130$^\circ$ FA. The highest CNRs, however, were obtained at 80$^\circ$ FA. Conclusion : Although SNR increased with the change of FA values from 50$^\circ$ to 130$^\circ$ at 3T SE T1WI, CNR was higher at 80$^\circ$ FA than at the usually used 90$^\circ$ FA. In addition, the SAR was decreased by using smaller FA. The CNR can be increased by using this optimized FA at 3T MR SE T1WI.

  • PDF

Quantitative Elemental Analysis in Soils by using Laser Induced Breakdown Spectroscopy(LIBS) (레이저유도붕괴분광법을 활용한 토양의 정량분석)

  • Zhang, Yong-Seon;Lee, Gye-Jun;Lee, Jeong-Tae;Hwang, Seon-Woong;Jin, Yong-Ik;Park, Chan-Won;Moon, Yong-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.5
    • /
    • pp.399-407
    • /
    • 2009
  • Laser induced breakdown spectroscopy(LIBS) is an simple analysis method for directly quantifying many kinds of soil micro-elements on site using a small size of laser without pre-treatment at any property of materials(solid, liquid and gas). The purpose of this study were to find an optimum condition of the LIBS measurement including wavelengths for quantifying soil elements, to relate spectral properties to the concentration of soil elements using LIBS as a simultaneous un-breakdown quantitative analysis technology, which can be applied for the safety assessment of agricultural products and precision agriculture, and to compare the results with a standardized chemical analysis method. Soil samples classified as fine-silty, mixed, thermic Typic Hapludalf(Memphis series) from grassland and uplands in Tennessee, USA were collected, crushed, and prepared for further analysis or LIBS measurement. The samples were measured using LIBS ranged from 200 to 600 nm(0.03 nm interval) with a Nd:YAG laser at 532 nm, with a beam energy of 25 mJ per pulse, a pulse width of 5 ns, and a repetition rate of 10 Hz. The optimum wavelength(${\lambda}nm$) of LIBS for estimating soil and plant elements were 308.2 nm for Al, 428.3 nm for Ca, 247.8 nm for T-C, 438.3 nm for Fe, 766.5 nm for K, 85.2 nm for Mg, 330.2 nm for Na, 213.6 nm for P, 180.7 nm for S, 288.2 nm for Si, and 351.9 nm for Ti, respectively. Coefficients of determination($r^2$) of calibration curve using standard reference soil samples for each element from LIBS measurement were ranged from 0.863 to 0.977. In comparison with ICP-AES(Inductively coupled plasma atomic emission spectroscopy) measurement, measurement error in terms of relative standard error were calculated. Silicon dioxide(SiO2) concentration estimated from two methods showed good agreement with -3.5% of relative standard error. The relative standard errors for the other elements were high. It implies that the prediction accuracy is low which might be caused by matrix effect such as particle size and constituent of soils. It is necessary to enhance the measurement and prediction accuracy of LIBS by improving pretreatment process, standard reference soil samples, and measurement method for a reliable quantification method.

Relationship of Average Volume of Alcohol Consumption and Binge Drinking to Arterial Stiffness in Community-Dwelling Healthy Adults (지역사회 건강한 성인에서 알코올 섭취량 및 폭음과 동맥경직도의 관련성)

  • Kweon, Sun-Seog;Lee, Young-Hoon
    • Journal of agricultural medicine and community health
    • /
    • v.37 no.1
    • /
    • pp.23-35
    • /
    • 2012
  • Objectives: The purpose of this study was to investigate the association of the average volume of alcohol consumption and binge drinking with arterial stiffness. Methods: The study population consisted of 5944 community-dwelling healthy adults aged 50 years and older. Average volume of alcohol consumption was calculated and frequency of binge drinking defined as the consumption of 7 or more drinks for men and 5 or more for women on a single occasion, was assessed using a structured interview. High brachial-ankle pulse wave velocity (baPWV), a marker of arterial stiffness, was defined as the highest gender-specific quartile of maximal baPWV distribution in the study population. Results: Compared to never drinkers, the multivariate-adjusted odds ratio (OR) of men who consumed 0.1-10.0, 10.1-20.0, 20.1-40.0, and >40.0 g/day was 0.93, 1.18, 1.38, and 2.36, respectively. The OR was 0.90, 0.97, 1.45, and 1.82 in women consuming 0.1-5.0, 5.1-10.0, 10.1-20.0, and >20.0 g/day, respectively. Binge drinking of <1 day/week (OR=1.66, 95% confidence interval [CI]=1.13-2.42) and ${\geq}1$ day/week (OR=1.61, 95% CI=1.04-2.50) were associated with increased risk for high baPWV in men, and binge drinking of ${\geq}1$ day/week (OR=3.12, 95% CI=1.16-8.34) was associated with increased risk for high baPWV in women. Conclusions: A J-shaped relationship between the average volume of alcohol consumption and high baPWV was observed, suggesting the detrimental effects of heavy alcohol drinking on arterial stiffness. Binge drinking was also significant risk factors for increased arterial stiffness, independently of the average volume of alcohol consumption.

Study of Catalytic Filter on the Removal of Dust and HVOC (촉매필터를 이용한 먼지 및 HVOC 제거 특성 연구)

  • Jeong, Soon Kwan;Park, Young Ok
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.80-85
    • /
    • 2008
  • Catalytic filter is capable of performing shallow bed dust filtration plus a catalytic reaction, promoted by a catalyst deposited in its inner structure. Such a feature may allow potential cost and space reduction in several environmental applications. Dust filtration and halogenated volatile organic compound (1,2-dichlorobenzene) destruction were carried out in a lab-scale reactor. $WO_3-V_2O_5/TiO_2$ supplied by MaGreen, which showed high catalytic acitivity at low temperature, was used as a catalyst. P-84 that can be operated under $250^{\circ}C$ was used as a felt. The catalytic activity and filtration efficiency of catalytic filters were investigated under the operating conditions, including temperature, face velocity, and dust concentration. The catalytic activity of catalytic filter increased with increasing temperature and the amount of catalyst loaded. The test results showed that the filtration efficiency was primarily affected by the face velocity. Pressure drop variations as a function of time were investigated for a variety of conditions. In case of virgin filter, a dramatic decrease in the pulse interval and a slightly increase in the base line pressure drop were observed. A relatively slow pressure drop build-up was recorded for the catalytic filter due to smooth and slippery surface characteristics of nanofiber. The catalytic filter indicated that high filtration efficiency over 99.98% and high catalytic activity over 90% at 1 m/min and $210^{\circ}C$.

ETS Sampler design for borehole radar receiver using 4 different clock phases (위상이 다른 4개의 클럭을 이용한 시추공 레이다 수신기용 ETS 샘플러 설계)

  • Yoo, Young-jae;Oh, Chaegon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.680-687
    • /
    • 2018
  • Borehole radar is a radar used for underground resources and geological exploration purposes. It needs a high-speed sampler to transmit electromagnetic waves with a pulse width of several ns and to receive reflected waves of several tens to several hundreds of MHz reflected from the object to be surveyed. ETS (Equivalent-Time Sampling), which can achieve sampling performance of several GHz with a sampling frequency of several tens of MHz, is suitable for use as a sampler of a borehole radar receiver. In this paper, we propose a method to control the sampling clock delay, which is the most important factor in ETS sampler design, using four clocks with phase difference of $90^{\circ}$ for one clock source. The proposed method can reduce the time required to acquire the data within the set interval by 1/25 than the conventional method using the delay generator. When the implemented sampler is applied to the receiver of existing borehole radar, it is possible to accumulate 58 additional times due to the shortened sampling time. In addition, by using one delay control logic compared with the conventional method using several sampling clock delay control logic in order to satisfy the target sampling range, it is possible to omit the correction process which was necessary in the past. As a result, the structure of the system can be simplified and a uniform sampler can be realized.

The Clinical Study on 40 Cases of Patient with Chronic Prostatitis (만성전립선염환자(慢性前立腺炎患者) 40예(例)에 대(對)한 임상적(臨床的) 고찰(考察))

  • Cho, Chung Sik;Kim, Chul Jung
    • Journal of Haehwa Medicine
    • /
    • v.8 no.2
    • /
    • pp.245-257
    • /
    • 2000
  • A clinical study was done 40 patients of chronic prostatitis who was treated in Dept. of Internal Medicine, Oriental Medicine Hospital, Taejon University, from 1 Mar. 1999 to 31 Oct. 1999. The results were as follows. 1. In distribution of age, 30's and 40's were 57.5% the most, 20's and 60's were 35.0%, 50's was 7.5%. 2. In distribution of past history, the urethritis(45.0%) was the most. 3. In distribution of ocupation, a white-collar worker was 35.0%, a business man was 22.5%, a public servant was 12.5%, etc. 4. Sitting the mean time of day were distributed 5~7 hours, above 7 hours, 3~5 hours, under 3 hours, etc. 5. The resting interval of a long distance drive were distributed 2 hours(35.0%), 3 hours(32.5%), etc. 6. The habit of enduring ejaculation during sexual intercourse was showed 45.0%. 7. The habit of enduring urination was showed 20.0%. 8. Influency of mental stress was showed 90.0%. 9. Ten cases(25.0%) were showed riding horse or riding bicycle. 10. Four cases(10.0%) were showed wearing tight trousers. 11. The habit of put a wallet his hip pocket was showed 57.5%. 12. The most common symptom was distributed the others symp-tom(66.8%) and the voiding symptom(63.3%) more than pain-neuro-logical symptom(37.5%) and symptom related with sexual function (26.6%). 13. In distribution of palpation, lower abdominal pain, lumbar pain, perineal or parascrotal pain were mostly showed right side. Moreover diagnosis of pulsation was weakly showed chi pulse of right. 14. Duration of disease were distributed above 1 year(82.5%), under 1 year(17.5%). Degree of prostatitis was severe showed adove 1 year. 15. The distribution of WBC count of the prostatic secretion, com-paring with before therapy and after therapy, were showed from 5 cases to 0 case in very many/HPF, from 23 cases to 13 cases in many/HPF, from 12 cases to 13 cases in 10~30/HPF, from 0 case to 13 cases in under 10/HPF. 16. Therapeutic improvement of symptom were distributed pain-neurological symptom(94.8%), the others symptom(90.8%), the void-ing symptom(89.6%) and symptom related with sexual function(67.5%). 17. Differentiation of symptoms and signs were distributed dificiency of spleen-lung vital energy, wetness-heat of lower warmer, dificiency of spleen-kidney yang, dificiency of kidney yin, wetness-phlegm, dificiency of vital energy and blood. The prescriptions were Bojungikgitang(44.6%), Yukmijihwangtang(20.7%), Palmijihwangtang(12.0%), etc.

  • PDF

Experimental Evaluation of an Analytical Method for Chlorofluorocarbons (CFSs) in Air and Water Using Gas Chromatography (가스 크로마토그래피를 이용한 대기와 물시료의 CFCs(chlorofluorocarbons) 분석법의 실험적 평가)

  • Koh, Dong-Chan;Choi, Beom-Kyu;Kim, Yong-Je
    • Economic and Environmental Geology
    • /
    • v.40 no.1 s.182
    • /
    • pp.129-140
    • /
    • 2007
  • CFC(CFC-12, CFC-11 and CFC-113) analytical system for air and water was constructed using a customized purge and trap extraction device and a gas chromatograph with an electron capture detector. Sampling methods of air and water for CFCs were also established. The analytical system was experimentally optimized to result in reproducibilities of triplicates less than 2% for current air samples and less than 5% for groundwater samples with CFC-12 concentration of 160 to 180 pg/kg, and verified with respect to the CFC system in USGS, which showed analytical results were in agreement within 10%. CFCs in air were monitored at three sites over 19-month period in the central part of South Korea, and the result indicates no significant local sources of CFCs in those areas. For groundwater in Jeju Island, CFCs were measured over a year with a two-month interval. The time-series data showed seasonal fluctuations which could be interpreted by the effect of recharge pulse derived from large amount of rainfall during monsoon period with a few month delay, which indicates high permeability of basaltic rocks in Jeju Island.