• Title/Summary/Keyword: Pulse design

Search Result 1,445, Processing Time 0.025 seconds

RESEARCH ON LASER-ACCELERATED PROTON GENERATION AT KAERI

  • PARK SEONG HEE;LEE KITAE;CHA YOUNG HO;JEONG YOUNG UK;BAIK SUNG HOON;YOO BYUNG DUK
    • Nuclear Engineering and Technology
    • /
    • v.37 no.3
    • /
    • pp.279-286
    • /
    • 2005
  • A prototype of a relativistic proton generation system, based on laser-induced plasma interaction, has been designed and fabricated. The system is composed of three major parts: a fs TW laser; a target chamber, including targets and controls; and a diagnostic system for charged particles and lasers. An Offner-type pulse stretcher for chirped pulse amplification (CPA) and eight pass pre-amplifier are installed. The main amplifier will be integrated with a new pumping laser. The design values of the laser at the first stage are 1 TW in power and 50 fs in pulse duration. We expect to generate protons with their maximum energy of approximately 3 MeV and the flux of at least $10^6$ per pulse using a 10 $\mu$m Al target. A prototype target chamber with eight 8-inch flanges, including target mounts, has been designed and fabricated. For laser diagnostics, an adaptive optics based on the Shack-Hartmann type, beam monitoring, and alignment system are all under development. For a charged particle, CR-39 detectors, a Thomson parabola spectrometer, and Si charged-particle detectors will be used for the density profile and energy spectrum. In this paper, we present the preliminary design for laser-induced proton generation. We also present plans for future work, as well as theoretical simulations.

Optimum Design for Piezoelectric Actuator of Inkjet head for Improving Performance (Inkjet head에서의 압전 작동기에 대한 성능 향상을 위한 최적설계)

  • 김시종;조종두
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.655-658
    • /
    • 1997
  • In this paper, we intend to develop optimized design algorithm by deciding design parameters which are considered in the first design stage of inkjet printer head. thus, the parameters are such as electric pulse, input voltage of actuator to operate actuator, shape dimension of actuator an so on. in the first design stage, according to such parameters, a lot of time and money to develop inkject printer head are needed. to reduce trial and error and to save development time in the first design stage, optimized design algorithm is required all the more. design algorithm was developed via commercial FE analysis code(ANSYS & COENTOR) for the readability and convenience of algorithm. the reasonability of algorithm was verified by implementing analysis of system stage based on the data of piezoelectric actuator which was designed through algorithm.

  • PDF

An Experimental Investigation of the G-M type Pulse Tube Refrigerator

  • Park, Seong-Je;Koh, Deuk-Yong;Yeom, Han-Kil;Hong, Yong-Ju;Kim, Hyo-Bong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.40-45
    • /
    • 2004
  • The experimental results of the G-M (Gifford-McMahon) type pulse tube refrigerators are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The objectives of this study are to develop the design technology of the G-M type pulse tube refrigerator and acquire its application methods for replacing G-M cryocooler. As a preliminary test, the refrigeration performances of the basic, orifice, and double inlet pulse tube refrigerators were investigated. The lowest temperature obtained in the one-stage pulse tube refrigerator was 34.4K and the refrigeration capacity at the optimum operation condition was 23W at 80K. And the lowest temperature of the second stage cold head in the two-stage pulse tube refrigerators was 18.3K and the refrigeration capacities at optimum condition were 0.45W at 20K and 20W at 80K, respectively. Finally, the lowest temperature obtained in the three-stage pulse tube refrigerator was 29.8K and the refrigeration capacity at the optimum operation condition was 1.3W for 40K and 5W for 70K.

Radial Pulse Wave Detection system for the Korean Medicine (한방용(韓方用) 맥파 검출시스템)

  • Lee, H.J.;Kim, J.W.;Kim, H.O.;Park, Y.B.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.66-69
    • /
    • 1991
  • This paper describes a design of transducer for non-invasively detecting pressure radial pulse wave in aterial system and a recording system that for the studing the aterial pulse diagnosis of korean traditional medicine. The mechanism of transducer is composed of sensing mechanism, pressure sensor, conditioning amplifier. The variation of radial pulse pressure in the sensing mechanism is converted to the electric signal by piezo-resistive pressure sensor and it converted to the digital signal after preprocessing via A/D converter. The converted signals inputed to the computer as data files and then it display to the monitor for waveform watching and this datas can be used as the aterial pulse diagnosis data. This system effectively detect non-differential radial pulse wave and we conside that if analizing the recorded radial pulse wave, compared each other, it can be helpful in quantify radial pulse wave diagonosis of the Korean traditional medicine.

  • PDF

Pneumatic Test Assessment of Pulse Separation Device for Multi-Pulse Rocket Motor (다중펄스 로켓모타 적용 펄스분리장치의 공압시험평가)

  • Lee, Dong-Won;Lee, Won-Bok;Kang, Seong-Yeop;Lee, Jong-Won;Chang, Hong-Been
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.101-104
    • /
    • 2010
  • A bulkhead-type pulse separation device has been developed for the multi-pulse rocket motor. The design parameters of the pulse separation device were the shape of the rupture disc slit, welding conditions, and the implementation of the seal disc. The pneumatic tests of the fabricated pulse separation devices showed that the rupture pressure increased as the quantity of the rupture disc slit and welding strength increased and the seal disc was implemented.

  • PDF

Experimental Study on a GM-type Two-Stage Pulse Tube Refrigerator for Cryopump Applications

  • Lee, S.J.;Hong, Y.J.;Park, S.J.;Kim, H.B.;Kwon, S.B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.2
    • /
    • pp.35-38
    • /
    • 2007
  • A single-stage and two-stage pulse tube refrigerators have been designed for cryopump application. The different diameters of pulse tube and regenerator have been investigated at single-stage pulse tube refrigerator(PTR). Experiments have been performed on single-stage PTR to reach minimum temperature with optimum valve opening at a few frequencies. And the two-stage pulse tube refrigerators have been assembled with tested single-stage pulse tube and tested. When orifice turn is opened to 9 and double inlet is opened to 3 at a single-stage, the lowest temperature of 33.7 K is achieved. The cooling capacity at single-stage is 38 W at temperature of 80 K. A two-stage pulse tube refrigerator has 16.3K at the second stage and 59.7K at the first stage. The cooling capacity achieved is 16.5 W at 80 K, the first stage and 0.6 W at 20 K, the second stage. Some details on the design of pulse tube refrigerator and the experimental apparatus are given.

Propagation and Crosstalk Characteristic Analysis of Pulse Shaped Signals on the Coupled Microstrip Lines (결합 마이크로스트립 선로상의 펄스형태 신호의 전파 및 누화 특성 해석)

  • Park, Sun-Keun;Kim, Nam;Rhee, Sung-Yup;Jang, Woo-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.5
    • /
    • pp.516-524
    • /
    • 1997
  • The propagation properties of various pulse signal types(square pulse, Gaussian pulse, trapezoid pulse, RF pulse) on coupled microstrip lines are investigated. Numerical integration technique which has its accuracy and is easily simulated, is used to obtain the time domain response of pulse signals. Frequency-dependent characteristics of coupled microstrip line is obtained using Jansen's approximate equation. The propagation properties of pulse signal on coupled microstrip lines is analyzed regarding to its geometric structure (relative permittivity ${varepsilon}_r$ substrate height h, strip width w of the microstrip line) and pulse width ${\tau}$ of signal pulse. The simulation results show that space between two lines is very significant parameter in pulse distortion in comparison of any other parameters. The results of this paper are compatible to the trade-off determination of relative permittivity, substrate height, strip width and pulse width of signal pulse when a design of MIC and MMIC is necessary.

  • PDF

Data Based Lower-Order Controller Design: Moment Matching Approach (데이터 기반 저차제어기 설계: 모멘트 정합 기법)

  • Kim, Young Chol;Jin, Lihua
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1903-1910
    • /
    • 2012
  • This paper presents a data based low-order controller design algorithm for a linear time-invariant process with a time delay. The algorithm is composed by combining an identification step based on open loop pulse test with a low-order controller design step to obtain the entire set of controllers achieving multiple performance specifications. The initial information necessary for this algorithm are merely the width and amplitude of a rectangular pulse, a controller of four types (PI, PD, PID, first-order), and design objectives. Various parametric approaches that have been developed are merged in the controller design algorithm. The resulting controller set satisfying the design objectives are displayed on the 2D and 3D graphics and thus it is very easy for us to pick a controller inside the admissible set because we can check the corresponding closed-loop performances visually.

Unknown Inputs Observer Design Via Block Pulse Functions

  • Ahn, Pius
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.3
    • /
    • pp.205-211
    • /
    • 2002
  • Unknown inputs observer(UIO) which is achieved by the coordinate transformation method has the differential of system outputs in the observer and the equation for unknown inputs estimation. Generally, the differential of system outputs in the observer can be eliminated by defining a new variable. But it brings about the partition of the observer into two subsystems and need of an additional differential of system outputs still remained to estimate the unknown inputs. Therefore, the block pulse function expansions and its differential operation which is a newly derived in this paper are presented to alleviate such problems from an algebraic form.

Design and Implementation of Multiplexing Pressure-measurement System using Multimode Optic Fiber (Multimode 광섬유를 이용한 다점 압력 계측 system 설계 및 구현)

  • 강기호;김명식;손정영;오명환
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.625-628
    • /
    • 1989
  • 광섬유와 micro변형기를 이용하여 다점 압력 계측 system을 구성하여 실험을 행하였다. 그 결과 pulse generator와 analog switch를 이용함으로써 100ns의 광 pulse를 쉽게 얻을 수 있었으며, 또한 3개의 광 pulse를 analog switch를 이용하여 쉽게 분리할 수 있었다. 한편 변형기에 가한 힘과 광 손실간의 상관관계를 이론치와 비교하여 조사한 결과 힘과 광손실간의 상관관계는 이론치와 실험치가 유사한 경향을 나타내는 것을 알 수 있었다.

  • PDF