• Title/Summary/Keyword: Pulse analysis system

Search Result 649, Processing Time 0.036 seconds

The interference effect of Frequency Hopping signal for 16 QAM system in impulsive noise environment (임펄스 잡음 환경하에서 16QAM시스템에 미치는 주파수 호핑 신호의 간섭효과)

  • 장은영;김원후
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1987.04a
    • /
    • pp.191-195
    • /
    • 1987
  • When a 160QAM receiver in the band of spread spectrum system is interfered with a pseudo-random frequency-hopp-ing signal the interference signal has the form of the pulse amplitude probability density function. Each interfrering pulse amplitude probability density function Each interfering pulse amplitude is dependent upon theprobability density function of hopping frequency and the selectivity characteristic of 16QAM system in this paper the error rate equation of a system performance has been derived in the above condition which are interfrerence form and impulsive noise environmensts. The results of system analysis show us that the system performance is de-graded by impulsive noise and interference power, which improved as the frequency hopping bandsidth increases whit respect to receiver bandwidth

  • PDF

Measurement and Analysis of Pulse Wave using Clip Type Pulsimeter Equipped with a Permanent Magnet and a Hall Device (영구자석과 홀소자로 구비된 집게형 맥진기를 이용한 맥진파형 측정과 분석)

  • Son, Il-Ho;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.3
    • /
    • pp.104-107
    • /
    • 2011
  • We measured signals at the "Guan" region of a radially arterial pulse using the prototype of a clamping pulsimeter equipped with a Hall effect device, which is passed signals through the voltage detecting hard ware system. The important four different measuring times of the period, systolic, reflective, and notch peaks for a temporally pulse signal are obtained and compared each other from the analysis for an arbitrary pulse wave of one position of small size permanent magnet. It is possible to measure the reproducible pulse rate and blood pressure by using the cuffless clip type pulsimeter without an unpleasant oppressive feeling due to the use of pressurization.

Parameter Evaluation of High-Power Pulse Transformer for L-Band 30-MW Klystron (L-band 30-MW 클라이스트론용 고출력 펄스트랜스포머의 파라미터 평가)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Kim, S.H.;Yang, H.R.;Moon, S.I.;Kwon, B.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1079-1081
    • /
    • 2007
  • An L-band Linear Accelerator System for E-beam sterilization is under construction for bio-technology application. The klystron-modulator system as an RF microwave source has an important role as major components to offer the system reliability for long time steady-state operations. A PFN line type pulse generator with a peak power of 71.5-MW, $7\;{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7\;{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present measurements and its analysis on the design parameters, and an initial test result as well as a design concept on the high-power pulse transformer.

  • PDF

Evaluation of pulse effect on frequency content of ground motions and definition of a new characteristic period

  • Yaghmaei-Sabegh, Saman
    • Earthquakes and Structures
    • /
    • v.20 no.4
    • /
    • pp.457-471
    • /
    • 2021
  • This study aims at providing a simple and effective methodology to define a meaningful characteristic period for special class of earthquake records named "pulse-like ground motions". In the proposed method, continuous wavelet transform is employed to extract the large pulse of ground motions. Then, Fourier amplitude spectra obtained from the original ground motion and the residual motion is simply compared. This comparison permits to define a threshold pulse-period (Tp∗) as the threshold period above which the pulse component has negligible contributions to the Fourier amplitude spectrum. The effect of pulse on frequency content of motions was discussed on the light of this definition. The advantage and superior features of the new definition were related to the inelastic displacement ratio (IDR) for single-degree-of-freedom systems with period equal to one half of the threshold period. Analyses performed for the proposed period at three ductility levels u=2,4,6 were compared with the results obtained at half of pulse period derived from wavelet analysis, peak-point method and the peak of product of the velocity and the displacement response spectra (Sv x Sd). According to the results, pulse effects on inelastic displacement ratio seem to be more important when $\frac{T_p^*}{T}=2$ (T is the fundamental vibration period of system). The results showed that utilizing of the proposed definition could facilitate an enhanced understanding of pulse-like records features.

Loss Analysis of Pulse Type Inverter Circuit for PLS (PLS용 펄스형 인버터 회로의 손실분석)

  • Jung Yong-Chae;Jung Yun-Chul;Kim Eui-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.146-148
    • /
    • 2006
  • The aim of the paper is to design the PLS(Plasma Lighting System) driving inverter circuit with optimal efficiency. In general, it is known that the PLS driven by a pulse has a higher light-conversion efficiency. There are the Class-E type resonant inverter and the semi-bridge inverter as a circuit which can make a pulse with low duty ratio. In this paper, we analyze the losses of the above two circuits. To verify the loss analysis, the inverter circuit with 220V 380W input consumption is manufactured and tested. Throughout the experimental results, the high efficiency PLS system has confirmed.

  • PDF

Algebraic Observer Design for Descriptor Systems via Block-pulse Function Expansions (블록펄스함수 전개를 이용한 Descriptor 시스템의 대수적 관측기 설계)

  • 안비오
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.6
    • /
    • pp.259-265
    • /
    • 2001
  • In the last two decades, many researchers proposed various usages of the orthogonal functions such as Walsh, Haar and BPF to solve the system analysis, optimal control, and identification problems from and algebraic form. In this paper, a simple procedure to design and algerbraic observer for the descriptor system is presented by using block pulse function expansions. The main characteristic of this technique is that it converts differential observer equation into an algerbraic equation. And furthermore, a simple recursive algorithm is proposed to obtain BPFs coefficients of the observer equation.

  • PDF

A Study on The State Estimation of The Time-Invariant Linear Systems via The Improved Parameter Estimation Method for The Block Pulse Coefficients (개선된 블록 펄스 계수 추정 기법을 이용한 선형 시불변계의 상태 추정에 관한 연구)

  • Kim, Tai-Hoon;Kim, Jin-Tae;Chung, Je-Wook;Sim, Jae-Seon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.4
    • /
    • pp.137-143
    • /
    • 2002
  • Because Block Pulse functions are used in a variety of fields such as the analysis and controller design of systems, it is necessary to find the more exact value of the Block Pulse series coefficients. This paper presents a method for the state estimation of the time-invariant linear systems via the improved estimation method for the Block Pulse coefficients by using the Simpson's rule. The proposed method using the Simpson's rule improve the accuracy of the Block Pulse coefficients.

Analysis on Code Used in Pulse Compression Method for Improving Resolution of Ultrasound Imaging System (초음파 영상 시스템에서의 해상도 개선을 위한 펄스압축기법에 사용되는 코드에 대한 분석)

  • You, Y.M.;Lee, H.H.;Song, T.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.115-116
    • /
    • 1998
  • Pulse echo techniques have been used for the conventional medical ultrasound imaging systems. However, their resolution is limited in the transmitted signal power. To overcome this limit, pulse compression method used in the radar systems was proposed. This system transmits a continuous coded signal and then compresses the received signal into the short and high resolution pulse by using correlator. The reflectors can be detected by cross-correlation between the transmitted signal and the received signal with the depth information. In this paper, we will present a comparative study of the performances of the most common sequences(pseudo-chirp, m-sequences, modified Golay code). The best result for improving resolution is obtained with the modified Golay Code.

  • PDF

Deterioration Diagnostic Techniques for Power Facilities by Analyzing Pulse-Height of leakage current (누설전류 파고분석에 의한 전력설비의 열화진단 기술)

  • 한주섭;김명진;손원진;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.367-370
    • /
    • 2001
  • This paper proposes a new deterioration diagnostic technique for power facilities by analyzing the pulse-height analysis of leakage current. Until now, various deterioration diagnostic techniques to prevent power system failures by deterioration of power facilities are suggested, and most of which measures leakage current amplitude only as a estimation parameter. In this experiment, it is known that the pulse heights of the leakage current are increased according to deterioration progress as well as there comes remarkable changes in pulse height distribution thereto. Therefore, the use of pulse height distribution in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only leakage current value. From the application test, it is confirmed that the proposed technique has sufficient performance to diagnose deterioration of power facilities.

  • PDF

Pulse-Sequence Analysis of Discharges in Air, Liquid and Solid Insulating Materials

  • Suwayno, Suwayno;Mizutani, Teruyoshi
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.528-533
    • /
    • 2006
  • Electrical discharges may occur in gas, liquid as well as solid insulating materials. This paper describes the investigation results on the discharges in air, silicone oil and low density polyethylene (LDPE) using needle plane electrode system under AC voltage of 50 Hz. The experimental results showed that for discharge in air (corona), discharge pulses were concentrated around the peak of applied voltage at negative half cycle. For silicone oil positive as well as negative discharges were observed which concentrated around the peak of applied voltage. The positive pulse number was smaller but the magnitude was higher than that of negative discharge. Discharges in void took place at wider range of phase of applied voltage. The unbalance in pulse number and magnitude similar to that of oil discharges were observed. For electrical treeing in LDPE, the discharges were spread before the zero cross of the applied voltage up to the peak at both positive and negative half cycles. The discharge pulse sequence analysis indicated that the PD occurrence in air, oil and void were strongly affected by the magnitude of applied voltage. However, for electrical treeing it was observed that the discharge occurrence was strongly affected by the time derivative of the applied voltage (dv/dt).