• Title/Summary/Keyword: Pulse Width Modulation (PWM)

Search Result 717, Processing Time 0.023 seconds

A Design of Current-mode Buck-Boost Converter using Multiple Switch with ESD Protection Devices (ESD 보호 소자를 탑재한 다중 스위치 전류모드 Buck-Boost Converter)

  • Kim, Kyung-Hwan;Lee, Byung-Suk;Kim, Dong-Su;Park, Won-Suk;Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.330-338
    • /
    • 2011
  • In this paper, a current-mode buck-boost converter using Multiple switching devices is presented. The efficiency of the proposed converter is higher than that of conventional buck-boost converter. In order to improve the power efficiency at the high current level, the proposed converter is controlled with PWM(pulse width modulation) method. The converter has maximum output current 300mA, input voltage 3.3V, output voltage from 700mV to 12V, 1.5MHz oscillation frequency, and maximum efficiency 90%. Moreover, this paper proposes watchdog circuits in order to ensure the reliability and to improve the performance of dc-dc converters. An electrostatic discharge(ESD) protection circuit for deep submicron CMOS technology is presented. The proposed circuit has low triggering voltage using gate-substrate biasing techniques. Simulated result shows that the proposed ESD protection circuit has lower triggering voltage(4.1V) than that of conventional ggNMOS(8.2V).

New Strategy for Eliminating Zero-sequence Circulating Current between Parallel Operating Three-level NPC Voltage Source Inverters

  • Li, Kai;Dong, Zhenhua;Wang, Xiaodong;Peng, Chao;Deng, Fujin;Guerrero, Josep;Vasquez, Juan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.70-80
    • /
    • 2018
  • A novel strategy based on a zero common mode voltage pulse-width modulation (ZCMV-PWM) technique and zero-sequence circulating current (ZSCC) feedback control is proposed in this study to eliminate ZSCCs between three-level neutral point clamped (NPC) voltage source inverters, with common AC and DC buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter.

Comparison of Temperature Loss from The Switching Method of Midium Voltage Multilevel Inverter (고압 멀티레벨 인버터의 스위칭 기법에 따른 온도 손실 비교)

  • Lee, Seul-A;Kang, Jin-Wook;Hong, Seok-Jin;Hyun, Seong-Wook;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.9-10
    • /
    • 2016
  • 최근 급속한 산업 발달로 인하여 기존의 수 MW급 대용량 인버터가 산업용 팬, 컴프레서, 고속 철도 시스템 등 여러 분야에 사용되면서 이와 관련된 대용량 인버터 연구가 활발히 진행 중이다. 이런 대용량 인버터는 고효율과 직병렬의 구성된 전력용반도체 소자를 동시다발적으로 제어되어야하기 때문에 멀티레벨 인버터의 구조가 가장 적합하다. Cascaded H-bridge 멀티레벨 인버터는 커패시터와 다이오드를 사용하지 않고 스위치만으로 구성하며, 필터를 따로 구성하지 않아도 정현파와 유사하게 전압을 출력할 수 있다. 이로 인해 고주파 감소 및 각 셀을 직렬로 연결하여 입력전압보다 높은 출력전압을 얻을 수 있다. 또한, 스위칭 방법에 따라 동일한 Cascaded H-bridge 멀티레벨인버터 토폴로지에서도 각 THD와 온도에 따른 손실이 달라질 수 있다. Cascaded H-bridge 멀티레벨 인버터에서 이용하는 스위칭 방식은 첫 번째로 유니폴라 방식을 기본으로 한 Phase-shift가 있다. 이는 180도 위상차를 갖는 2개의 레퍼런스 파형과 위상천이가 된 캐리어 파형의 비교로 PWM (Pulse Width Modulation) 을 수행한다. 두 번째 방식으로는 Level-shift가 있다. 이는 캐리어 파형을 IPD (In-Phase Disposition) 방식으로 수직적으로 대역폭이 연속적이게 나열하여 레퍼런스 파형과 비교하는 PWM방식이다. 본 논문에서는 Phase-shift와 Level-shift 방식에 따른 Cascaded H-bridge 인버터와 NPC (Neutral Point Clamped) 인버터를 결합한 토폴로지에서의 온도에 따른 손실을 분석하고, 시뮬레이션을 통하여 비교 분석하였다.

  • PDF

Phase-Shift Full-Bridge DC-DC Converter using the One-Chip Micom (단일칩 마이컴을 이용한 위상변위 방식 풀브리지 직류-직류 전력변환기)

  • Jeong, Gang-Youl
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.517-527
    • /
    • 2021
  • This paper presents the phase-shift full-bridge DC-DC converter using the one-chip micom. The proposed converter primary is the full-bridge power topology that operates with the unipolar pulse-width modulation (PWM) by the phase-shift method, and the secondary is the full-bridge full-wave rectifier composed of four diodes. The control of proposed converter is performed by the one-chip micom and its MOSFET switches are driven by the bootstrap circuit. Thus the total system of proposed converter is simple. The proposed converter achieves high-efficiency using the resonant circuit and blocking capacitor. In this paper, first, the power-circuit operation of proposed converter is explained according to each operation mode. And the power-circuit design method of proposed converter is shown, and the software control algorithm on the micom and the feedback and switch drive circuits operating the proposed converter are described, briefly. Then, the operation characteristics of proposed converter are validated through the experimental results of a designed and implemented prototype converter by the shown design and implementation method in this paper. The highest efficiency in the results was about 92%.

Circuit Modeling and Simulation of Active Controlled Field Emitter Array for Display Application (디스플레이 응용을 위한 능동 제어형 전계 에미터 어레이의 회로 모델링 및 시뮬레이션)

  • Lee, Yun-Gyeong;Song, Yun-Ho;Yu, Hyeong-Jun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.2
    • /
    • pp.114-121
    • /
    • 2001
  • A circuit model for active-controlled field emitter array(ACFEA) as an electron source of active-controlled field emission display(ACFED) has been proposed. The ACFEA with hydrogenated amorphous silicon thin-film transistor(a-Si:H TFT) and Spindt-type molibdenum tips (Spindt-Mo FEA) has been fabricated monolithically on the same glass. A-Si:H TFT is used as a control device of field emitters, resulting in stabilizing emission current and lowering driving voltage. The basic model parameters extracted from the electrical characteristics of the fabricated a-Si:H TFT and Spindt-Mo FEA were implemented into the ACFEA model with a circuit simulator SPICE. The accuracy of the equivalent circuit model was verified by comparing the simulated results with the measured one through DC analysis of the ACFEA. The transient analysis of the ACFEA showed that the gate capacitance of FEA along with the drivability of TFT strongly affected the response time. With the fabricated ACFEA, we obtained a response time of 15$mutextrm{s}$, which was enough to make 4bit/color gray scale with the pulse width modulation (PWM).

  • PDF

The Characteristics Analysis and Design of High-Frequency Isolated Type ZVZCS PS-PWM DC-DC Converter with Fuel Cell Generation System (연료전지 발전시스템에 적용된 고주파 절연형 ZVZCS PS-PWM DC-DC 컨버터의 설계 및 특성 해석)

  • Suh, Ki-Young;Mun, Sang-Pil;Kim, Dong-Hun;Lee, Hyun-Woo;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.21-28
    • /
    • 2006
  • In this paper, the proposed full-bridge high frequency isolated zoo voltage and zero current switching phase shifted pulse width modulation(ZVZCS PS-PWM)DC-DC converter among fuel cell generation system consist of 1.2[kW] fuel cell of Nexa Power Module, full-bridge DC-DC converter to boost the fuel cell low voltage($28{\sim}43[%]$) to 380[VDC] and a single phase full-bridge inverter is implemented to produce AC output(220[VAC], 60[Hz]). A tapped inductor filter with freewheeling diode is newly implemented in the output filter of the proposed full-bridge high frequency isolated ZVZCS PS-PWM DC-DC converter to suppress circulating current under the wide output voltage regulation range, thus to eliminate the switching and transformer turn-on/off over-short voltage or transient phenomena. Besides the efficiency of $93{\sim}97[%]$ is obtained over the wide output voltage regulation ranges and load variations.

A Study on PWM Speed Controller for Long line Fishing Motor (어로 작업용 연승기 전동기의 PWM 속도제어기에 관한 연구)

  • Vuong, Duc-Phuc;Bae, Cherl-O;Ahn, Byong-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.1
    • /
    • pp.97-102
    • /
    • 2015
  • The long line fishing machine is combined with motor and two disc rollers has used on the small size fishing-boat under 1 ton located in near Jeollanam-do seaside. The long line fishing motor is controlled only one direction because the fishing line is loaded heavily at pulling up. On this paper we made the long line fishing 400W power motor controller which it was usually applied under 1 ton fishing boat, and designed the controller using PWM chip, Half bridge driver and MOSFET for one direction motor control. Furthermore some user convenience devices were added like battery indicator and safety protection circuit for battery overdischarge and battery source wire mismatch connection. So we protected the battery from overdicharging when the battery voltage was below 11.5V and fishermen didn't need to worry about source lines misconnection anymore. We confirmed the test version of controller was the good working condition at land and sea.

A Study on Operation Method of Protection Device for LVDC Distribution Feeder in Light Rail System (경전철용 LVDC 배전계통의 보호기기 운용 방안에 관한 연구)

  • Kang, Min-Kwan;Choi, Sung Sik;Lee, Hu-Dong;Kim, Gi-Yung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.25-34
    • /
    • 2019
  • Recently, when a fault occurs at a long-distance point in a LVDC (low voltage direct current) distribution feeder in a light rail system, the magnitude of the current can decrease to less than that of the load current of a light rail system. Therefore, proper protection coordination method to distinguish a fault current from a load current is required. To overcome these problems, this paper proposes an optimal algorithm of protection devices for a LVDC distribution feeder in a light rail system. In other words, based on the characteristics of the fault current for ground resistance and fault location, this paper proposes an optimal operation algorithm of a selective relay to properly identify the fault current compared to the load current in a light rail system. In addition, this paper modelled the distribution system including AC/DC converter using a PSCAD/EMTDC S/W and from the simulation results for a real light rail system, the proposed algorithm was found to be a useful and practical tool to correctly identify the fault current and load current.

Identification of Motor Parameters and Improvement of Voltage Error for Improvement of Back-emf Estimation in Sensorless Control of Low Speed Operation (저속 센서리스 제어의 역기전력 추정 성능 향상을 위한 모터 파라미터 추정과 전압 오차의 개선)

  • Kim, Kyung-Hoon;Yun, Chul;Cho, Nae-Soo;Jang, Min-Ho;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.5
    • /
    • pp.635-643
    • /
    • 2018
  • This paper propose a method to identify the motor parameters and improve input voltage error which affect the low speed position error of the back-emf(back electromotive force) based sensorless algorithm and to secure the operation reliability and stability even in the case where the load fluctuation is severe and the start and low speed operation frequently occurs. In the model-based observer used in this paper, stator resistance, inductance, and input voltage are particularly influential factors on low speed performance. Stator resistance can cause resistance value fluctuation which may occur in mass production process, and fluctuation of resistance value due to heat generated during operation. The inductance is influenced by the fluctuation due to the manufacturing dispersion and at a low speed where the change of the current is severe. In order to find stator resistance and inductance which have different initial values and fluctuate during operation and have a large influence on sensorless performance at low speed, they are commonly measured through 2-point calculation method by 2-step align current injection. The effect of voltage error is minimized by offsetting the voltage error. In addition, when the command voltage is used, it is difficult to estimate the back-emf due to the relatively large distortion voltage due to the dead time and the voltage drop of the power device. In this paper, we propose a simple circuit and method to detect the voltage by measuring the PWM(Pulse Width Modulation) pulse width and compensate the voltage drop of the power device with the table, thereby minimizing the position error due to the exact estimation of the back-emf at low speed. The suitability of the proposed algorithm is verified through experiment.

Modelling a Stand-Alone Inverter and Comparing the Power Quality of the National Grid with Off-Grid System

  • Algaddafi, Ali;Brown, Neil;Rupert, Gammon;Al-Shahrani, Jubran
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Developments in power electronics have enabled the widespread application of Pulse Width Modulation (PWM) inverters, notably for connecting renewable systems to the grid. This study demonstrates that a high-quality power can be achieved using a stand-alone inverter, whereby the comparison between the power quality of the stand-alone inverter with battery storage (off-grid) and the power quality of the utility network is presented. Multi-loop control techniques for a single phase stand-alone inverter are used. A capacitor current control is used to give active damping and enhance the transient and steady state inverter performance. A capacitor current control is cheaper than the inductor current control, where a small current sensing resistor is used. The output voltage control is used to improve the system performance and also control the output voltage. The inner control loop uses a proportional gain current controller and the outer loop is implemented using internal model control proportional-integral-derivative to ensure stability. The optimal controls are achieved by using the Sisotool tool in MATLAB/Simulink. The outcome of the control scheme of the numerical model of the stand-alone inverter has a smooth and good dynamic performance, but also a strong robustness to load variations. The numerical model of the stand-alone inverter and its power quality are presented, and the power quality is shown to meet the IEEE 519-2014. Furthermore, the power quality of the off-grid system is measured experimentally and compared with the grid power, showing power quality of off-grid system to be better than that of the utility network.