• Title/Summary/Keyword: Pulse Mode Response Time

Search Result 18, Processing Time 0.027 seconds

Life Firing Test of 1 N-class Monopropellant Thruster Development Model -Part II: Pulse Mode Performance (1 N급 단일추진제 추력기 개발모델의 장기수명 연소시험 -Part II: 펄스모드 성능 특성)

  • Won, Su-Hee;Kim, Su-Kyum;Jun, Hyoung-Yoll;Lee, Jun-Hui;Park, Su-Hyang;Lee, Jae-Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.6
    • /
    • pp.68-74
    • /
    • 2014
  • During the life firing test of 1 N-class thruster development model, pulse mode performance and performance changes were examined. The deviation of pulse mode response time according to thruster feed pressure was relatively small and the resultant ignition delay, response time, tail-off time were 32-35 ms, 86-91 ms, 89-98 ms, respectively. For the stabilized pulse region the impulse bit revealed the outstanding reproducibility of 1.41, 1.32, 2.10% at $3{\sigma}$. During the life firing test, the impulse bit was decreased with limited amounts, therefore the pulse mode performance could be considered to be maintained. The thrust centroid was also maintained during the life firing test.

Rapid Dynamic Response Flyback AC-DC Converter Design

  • Chang, Changyuan;Wu, Menglin;He, Luyang;Zhao, Dadi
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1627-1633
    • /
    • 2018
  • A constant voltage AC-DC converter based on digital assistant technology is proposed in this paper, which has rapid dynamic response capability. The converter operates in the PFM (Pulse Frequency Modulation) mode. According to the load state, the compensation current produced by the digital compensation module was injected into the CS pin to adjust the switching pulse width dynamically and improve the dynamic response. The control chip is implemented based on NEC $1{\mu}m$ 5V/40V HVCMOS process. A 5V/1.2A prototype has been built to verify the proposed control method. When the load jumps from idle to heavy, the undershoot time is only 7.4ms.

Verilog Modeling of Transmission Line for USB 2.0 High-Speed PHY Interface

  • Seong, Ki-Hwan;Lim, Ji-Hoon;Kim, Byungsub;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.463-470
    • /
    • 2014
  • A Verilog model is proposed for transmission lines to perform the all-Verilog simulation of high-speed chip-to-chip interface system, which reduces the simulation time by around 770 times compared to the mixed-mode simulation. The single-pulse response of transmission line in SPICE model is converted into that in Verilog model by converting the full-scale analog signal into an 11-bit digital code after uniform time sampling. The receiver waveform of transmission line is calculated by adding or subtracting the single-pulse response in Verilog model depending on the transmitting digital code values with appropriate time delay. The application of this work to a USB 2.0 high-speed PHY interface reduces the simulation time to less than three minutes with error less than 5% while the mixed-mode simulation takes more than two days for the same circuit.

Pulse Propagation Characteristics of Multilayer-Multiconcuctor Transmission Line Network (다층 다도체 선로로 구성된 회로의 펄스전송 특성)

  • 장행종;임영석
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.10
    • /
    • pp.39-47
    • /
    • 1994
  • In this paper, by modeling the Multilayer-Multiconductor Transmission Line(MMTL) with the characteristic parameters-effective dielectric constant, eigen modal voltages, characteristic impedances at each mode, pulse propagation characteristics of MMTL network are simulated. Transmission line modelling is performed in frequency domain, then time domain resposes are obtained by transforming the frequency domain response using fast Fourier transform.

  • PDF

Small Signal Modeling for the PWM Series Resonant Converter (PWM-SRC) (펄스-폭 변조방식의 직렬공진 컨버터의 소신호 모델링)

  • Choi, Hyun-Chil
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.11
    • /
    • pp.1441-1447
    • /
    • 1999
  • A discrete time domain modeling is presented for the pulse-width modulated series resonant converter (PWM-SRC) with a discontinuous current mode. This nonlinear system is linearized about its equilibrium state to obtain a linear discrete time model for the investigation of small signal performances such as the stability and transient response. The usefulness of this small signal model is verified through the dynamic simulation.

  • PDF

Operation modes and Protection of VS(Vertical Stabilization) Converter for International Thermonuclear Experimental Reactor (국제 핵융합실험로용 VS(Vertical Stabilization) 컨버터의 운전모드 및 보호동작)

  • Jo, Hyunsik;Jo, Jongmin;Oh, Jong-Seok;Suh, Jae-Hak;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.130-136
    • /
    • 2015
  • This study describes the structure and operation modes of vertical stabilization (VS) converter for international thermonuclear experimental reactor (ITER) and proposes a protection method. ITER VS converter supplies voltage (${\pm}1000V$)/current (${\pm}22.5kA$) to superconducting magnets for plasma current vertical stabilization. A four-quadrant operation must be achieved without zero-current discontinuous section. The operation mode of the VS converter is separated in 12-pulse mode, 6-pulse mode and circulation current mode according to the magnitude of the load current. Protection measures, such as bypass and discharge, are proposed for abnormal conditions, such as over current, over voltage, short circuit, and voltage sag. VS converter output voltage is controlled to satisfy voltage response time within 20 msec. Bypass operation is completed within 60 msec and discharge operation is performed successfully. The feasibility of the proposed control algorithm and protection measure is verified by assembling a real controller and implementing a power system including the VS converter in RTDS for a hardware-in-loop (HIL) facility.

The Response Characteristics of the Hydrogen Peroxide Monopropellant Thruster as Injector and Catalyst Grain Size (인젝터 방식 및 촉매 알갱이 크기에 따른 과산화수소 단일추진제 추력기의 응답 특성)

  • An, Sung-Yong;Park, Dae-Jong;Chung, Seung-Mi;Kwon, Se-Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.1
    • /
    • pp.19-26
    • /
    • 2009
  • The response characteristics of $H_2O_2$ monopropellant thrusters at a pulse mode were presented in this paper. A catalyst bed was fixed to $MnO_2$/$Al_2O_3$ to investigate the thruster design effect to response time. Three different thrusters (50 N class) having different injectors, ullage volumes, catalyst grain sizes, and reactor volumes were prepared to investigate the response characteristics. As a result, the ignition delay, pressure rising and tail-off time of case 2-2 thruster with 16-20 mesh catalyst size were 14, 108, 94 ms respectively, which were comparable to requirement of response time at commercial hydrazine thrusters.

Construction and Performance Characterization of Time-correlated Single Photon Counting System having Picosecond Resolution (피코초 분해능의 시간 상관 단광자 계수 장치 구성 및 동작 특성)

  • 이민영;김동호
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.90-99
    • /
    • 1994
  • Picosecond time-correlated single photon counting system and time-resolved luminescence spectrometer were constructed, employing a mode-locked picosecond laser, fast electronics, and microchannel plate tube. It has been shown that the instrument response function critically depends on laser pulse shape, timing jitter and walk of the electronics, and characteristics of detector and amplifier. Correcting time dispersion in the optical system, the best instrument response function obtained appears to be 25 ps, which made it possible to measure the luminescence lifetime with less than 10 ps resolution in the picosecond to microsecond range. range.

  • PDF

Spectral Analysis of Heart Rate Variability in ECG and Pulse-wave using autoregressive model (AR모델을 이용한 심전도와 맥파의 심박변동 스펙트럼 해석)

  • Kim NagHwan;Lee EunSil;Min HongKi;Lee EungHyuk;Hong SeungHong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • The analysis of power spectrum based on linear AR model is applied widely to quantize the response of autonomic nerve noninvasively, In this paper, we estimate the power spectrum density for heartrate variability of the electrocadiogram and pulse wave for short term data(less than two minute), The time series of heart rate variability is obtained from the time interval(RRI, PPI) between the feature point of the electrocadiogram and pulse wave for normal person, The generated time series reconstructed into new time series through polynomial interpolation to apply to the AR mode. The power spectrum density for AR model is calculated by Burg algorithm, After applying AR model, the power spectrum density for heart rate variability of the electrocadiogram and the pulse wave is shown smooth spectrum power at the region of low frequence and high frequence, and that the power spectrum density of electrocadiogram and pulse wave has similar form for same subject.

  • PDF

Duplex Pulse Frequency Modulation Mode Controlled Series Resonant High Voltage Converter for X-Ray Power Generator

  • Chu Enhui;Ogura Koki;Moisseev Serguei;Okuno Atsushi;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.295-300
    • /
    • 2001
  • A variety of high voltage DC power supplies employing the high frequency inverter are difficult to achieve soft switching considering a quick response and no overshoot response under the wide load variation ranges which are used in medical-use x-ray high voltage generator from 20kV to 150kV in the output voltage and from 0.5mA to 1250mA, respectively. The authors develops soft switching high voltage DC power supply designed for x-ray power generator applications, which uses series resonant inverter circuit topology with a multistage voltage multiplier instead of a conventional high voltage diode rectifier connected to the second-side of a high-voltage transformer with a large turn ratio. A constant on-time dual mode frequency control scheme operating under a principle of zero-current soft switching commutation is described. Introducing the multistage voltage multiplier, the secondary transformer turn-numbers and stray capacitance of high-voltage transformer is effective to be greatly reduced. It is proved that the proposed high-voltage converter topology with dual mode frequency modulation mode control scheme is able to be the transient response and steady-state performance in high-voltage x-ray tube load. The effectiveness of this high voltage converter is evaluated and discussed on the basis of simulation analysis and observed data in experiment.

  • PDF