• Title/Summary/Keyword: Pulse Analysis

Search Result 2,092, Processing Time 0.032 seconds

ANALYSIS OF THREE PHASE INDUCTION MOTOR FED BY P.N.W BOXES ALGORITHM

  • Nasr, M.Sh;Abdul-baki, E.M.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.1035-1040
    • /
    • 1989
  • This paper describes first Boxes algorithm as a good method to generate the pulse patterns for a pulse width modulated inverter which has a good characteristics and simple to excute. Second we present the motor analysis fed by P.W.M. inverter in steady-state operation. In this analysis we improve the MRF ( Multiple Reference Frames ) to can be easy apply to analyse all the induction motor parameters. Finally we presented all the results obtained for a 3-phase induction motor.

  • PDF

Studies on Working Intensity in Felling Operation of the Thinning Forest -In Thinning of Some Conifer Species- (벌채작업(伐採作業)에서의 작업강도(作業强度) 측정연구(測定硏究) -침엽수(針葉樹) 간벌림에(間伐林)서-)

  • Park, Soo-Kyoo;Kang, Gun-Uh
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.3
    • /
    • pp.396-408
    • /
    • 1996
  • The purposes of this study were to standardise the forest working system to design the intensity of working system in felling operation of the thinning forest in our country as well as to contrive the improvement of working method and the increase of productivity. For the purpose of investigating these, element working was classified by felling operation in softwood thinning forest, and a pulse rate were measured and analyzed. The results were as follow : 1. From the analysis of the pulse frequence measurment, the average pulse showed 108 pulse per minute for worker A in the total of pure working time, 130 pulse per minutes for worker B, 119 pulse per minute for worker C and 125 pulse per minute for worker D, respectively. 2. From the results of the pulse frequence analysis according to element working classification, the highest pulse frequence represented 115 pulse per minute for worker A in the circumference, 131 pulse per minute for worker B in the movement, 122 pulse per minute for worker C in the limbing operation and 128 pulse per minute for work D in hang-up. 3. If the original pulse frequence was 100% for workers, the working intensity showed as follow : worker A was 160%(original pulse frequence was 61=100%) for the total of the working intensity and 188% for the circumference among element working. Worker B was 220%(original pulse frequence was 57=100%) for the total of the working intensity and 229 for movement among element working. Worker C was 159%(original pulse frequence was 73=100%) for the total of the working intensity and 168% for limbing operation among the element working. Worker D was 156%(original pulse frequence was 70=100%) for the total of working intensity and 182% for hang-up among element working. 4. At the limit point of Labor performance rating, showing the total of working intensity, overtime pulse rate per minute was 30 for worker A, 207 for worker B, 14 for worker C and 67 for worker D. Worker B was highest in working intensity, and got physically a big load.

  • PDF

Clinical Study of the Floating-Sinking Pulse Quantification Analysis on Ages, Left/Right, and Palpation Positions (20/60대 여성을 중심으로 살펴본 좌우 촌관척 부/침맥 정량화 임상연구)

  • Kim, Jae-Uk;Kim, Sung-Hun;Jeon, Young-Ju;Ryu, Hyun-Hee;Lee, Yu-Jung;Lee, Hae-Jung;Kim, Jong-Yoel
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1193-1198
    • /
    • 2009
  • Pulse diagnosis is a central diagnosis method used in traditional Oriental medicine. To standardize and modernize the pulse diagnosis method, it is essential to develop an instrument-based reinterpretation of the clinically used pulse images in terms of the physical quantities such as the strength, period, width, length, and depth of the pulse. As a step towards such standardization, we conducted a clinical study on the floating/sinking pulses based on an automated palpation instrument (3D-MAC, Daeyo Medi, Korea) for 213 female subjects in their 20s and 174 female subjects in their 60s. The floating/sinking pulses are the two representative pulse images depending only on the depth of the pulse, and can be conveniently scaled by the coefficient of the floating-sinking pulse ($C_{fs}{\in}(0,1)$), which represents how strong one should apply the hold-down pressure to obtain the maximal pulse strength. As a result, primarily we found that it tends to appear more floating-like pulse ($C_{fs}{\rightarrow}0$) at Gwan and more sinking-like pulse ($C_{fs}{\rightarrow}1$) at Cheek, at both age groups and at both wrists. This result is consistent with a previous study on the geometrical structure of the blood vessel by an ultrasonograph. Second, the pulse tends to be more sinking-like in the age group of 60s than 20s. Finally, the pulses at the right palpation positions were found to be more sinking-like than the left, at both age groups.

Non-destruction and Neutralization Properties of Mortar Mixed with Non-active Hwangto and Stone Dust (비활성 황토와 석분을 혼입한 모르타르의 비파괴 및 중성화 특성)

  • 성찬용;윤준노
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.3
    • /
    • pp.59-64
    • /
    • 2003
  • Hwangto would be an environment-friendly material that can be readily used. The purpose of this study is to obtain the absorption ratio, ultrasonic pulse velocity and neutralization of the mortar with non-active Hwangto and stone dust. The absorption ratio and neutralization depth are increased with increase of non-active Hwangto. But, the ultrasonic pulse velocity is decreased with increase of non-active Hwangto. In results of SEM analysis, the crystals are increased with increase of non-active Hwangto.

Time-Domain Numerical Investigation of Ring Resonator Optical Delay Devices

  • Chung, Youngchul
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.441-446
    • /
    • 2013
  • A split-step time-domain model for the analysis of pulse delay characteristics through ring resonator all-pass filters (APF's) is developed and its accuracy is checked. The dependence of the delay time and pulse distortion on the coupling ratios is investigated using the model. It is observed that the bandwidth of the APF's needs to be wide enough to minimize the pulse distortion.

Analysis and Performance Improvement of Integrated E1 Pulse Generator for EMP Protection Performance Test (EMP 방호성능 시험용 통합형 E1 펄스 발생장치 분석 및 성능 개선)

  • Kim, Young-Jin;Kang, Ho-jae;Jeong, Young-Kyung;Youn, Dong-Gi;Park, Yong Bae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.6
    • /
    • pp.415-423
    • /
    • 2018
  • We herein investigate the E1 pulse for evaluating the conducted performance of transmission lines connected to the electromagnetic pulse protection facilities against a conducted high-altitude electromagnetic pulse threat exposed to an external electromagnetic environment. The existing E1 pulse generator uses the Marx generator high-voltage step-up method; however, in this research, we used the Tesla transformer method to easily change the broadband output voltage(30 to 350 kV). We also analyzed the controller, power supply, high-voltage booster, and pulse-shaping device. The E1 pulse performance using the Tesla transformer was predicted through simulations and validated by measurements.

Integrated Circuit Implementation and Analysis of a Pulse-type Hodgkin-Huxley Neuron Model (펄스형 호지킨-혁슬리 신경세포 모델의 집적회로 구현 및 분석)

  • Kwon, Bo-Min;Jung, Jin-Woo;Park, Ju-Hong;Lee, Je-Won;Park, Yong-Su;Song, Han-Jung
    • 전자공학회논문지 IE
    • /
    • v.46 no.1
    • /
    • pp.16-22
    • /
    • 2009
  • Integrated circuit of a pulse-type neuron for Hodgkin-Huxley model is implemented in a $0.5{\mu}m$ 1 poly 2 metal CMOS technology. Proposed pulse-type neuron model consist of input stage with summing function and pulse generating block which make neuron pulse above threshold value. Pulse generating circuit consist of several transistors, capacitors and negative resistor with a charge supply function. SPICE simulation results show that neuron pulse is generated above threshold current of 70 nA. Measurements of the fabricated pulse type neuron chip in condition of 5 V power supply are shown and compared with the simulated results.

Design, Test and Evaluation on the PSD with Thermal Barrier Type for Subscale Dual Pulse Rocket Motor (격막형 PSD를 적용한 소형 추진기관 설계 및 시험평가)

  • Kim, Jinyong;Kwon, Taeha;Lee, Wonbok;Cho, Wonman;Lee, Bangeop;Yun, Namgyun;Rhee, Youngwoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.6
    • /
    • pp.82-87
    • /
    • 2014
  • Dual pulse rocket motor has a rocket motor with different pulse grains divided by a pulse separation device such as a fragile bulkhead or a thermal barrier type. It distributes thrust energy very effectively via pulse separation device to improve range and terminal velocity of a missile. This paper contains the thermal barrier design and experimental analysis through ground firing tests of small dual pulse motors. The results will be applied to the design, test and evaluation of the scale up dual pulse rocket motor.

Analysis of Arterial Stiffness by Age Using Pulse Waveform Measurement of 5-levels Graded Pressure (5단계 가압 맥파측정에 의한 연령별 혈관 경화도 분석)

  • Kwon, Sun-Min;Kang, Hee-Jung;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.27 no.2
    • /
    • pp.107-120
    • /
    • 2010
  • Objectives : The aim of this study is to measure pulse waveforms by applying 5-level graded pressure, and selecting optimum pulse waveforms. Also to proposing the possibility of using AW(Area of the 1/3 upper height of h1) rate in respect to AT(Total Area) for risk assessment of hypertension or arteriosclerosis is another aim of the study. Methods : Pulse waveforms of normotensive were measured by 5-level graded pressure. The pulse waveforms well reflecting properties of blood vessel(having the largest h1) were selected for optimum pulse waveforms. Various parameters(h-parameter, t-parameter, and others) of optimum pulse waveforms were analyzed. AIx(Augmentation index) was calculated by height-parameters to assess arterial stiffness. The area rate of the 1/3 upper height for h1 in respect to total area was analyzed according to aging. Results : According to aging 1. in height-parameter, h2 and h3 were increased but h5 was decreased. 2. In time-parameter, t2, t3, and t5 were getting short. 3. Area of systolic period was increased, and that of diastolic period decreased. 4. AIx rose by aging. 5. AW was significantly increased despite no changes in AT. Conclusions : By analyzing optimum pulse waveforms of 5-level graded pressure method, we could complement weakness of single graded pressure method. Also, possibility of applying the AW rate to risk assessment of hypertension or arteriosclerosis was confirmed in normotensive population which might not be assessed by AIx.

Parameter Evaluation of High-Power Pulse Transformer for L-Band 30-MW Klystron (L-band 30-MW 클라이스트론용 고출력 펄스트랜스포머의 파라미터 평가)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Kim, S.H.;Yang, H.R.;Moon, S.I.;Kwon, B.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1079-1081
    • /
    • 2007
  • An L-band Linear Accelerator System for E-beam sterilization is under construction for bio-technology application. The klystron-modulator system as an RF microwave source has an important role as major components to offer the system reliability for long time steady-state operations. A PFN line type pulse generator with a peak power of 71.5-MW, $7\;{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7\;{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present measurements and its analysis on the design parameters, and an initial test result as well as a design concept on the high-power pulse transformer.

  • PDF