DOI QR코드

DOI QR Code

Analysis and Performance Improvement of Integrated E1 Pulse Generator for EMP Protection Performance Test

EMP 방호성능 시험용 통합형 E1 펄스 발생장치 분석 및 성능 개선

  • Received : 2018.02.12
  • Accepted : 2018.05.23
  • Published : 2018.06.30

Abstract

We herein investigate the E1 pulse for evaluating the conducted performance of transmission lines connected to the electromagnetic pulse protection facilities against a conducted high-altitude electromagnetic pulse threat exposed to an external electromagnetic environment. The existing E1 pulse generator uses the Marx generator high-voltage step-up method; however, in this research, we used the Tesla transformer method to easily change the broadband output voltage(30 to 350 kV). We also analyzed the controller, power supply, high-voltage booster, and pulse-shaping device. The E1 pulse performance using the Tesla transformer was predicted through simulations and validated by measurements.

본 논문에서는 HEMP(High-altitude Electromagnetic Pulse)와 같은 외부전자파 환경에 노출된 EMP 방호시설에 연결된 전송선로에 유기된 HEMP 위협에 대한 전도성 방호 성능 평가를 위한 E1 펄스에 대해 연구한다. 기존 E1 펄스 발생장치는 Marx Generator 고전압 승압 방식을 사용하지만, 본 연구에서는 광대역 출력전압(30~350 kV) 가변이 용이한 Tesla Transformer 방식을 사용한다. E1 펄스 발생장치의 구성 요소인 제어기, 전원장치, 고전압 승압장치, 펄스성형장치도 각각 분석한다. Tesla Transformer를 이용한 E1 펄스는 시뮬레이션을 통해 성능을 예측하고, 실제 개발된 장비를 이용하여 결과를 검증한다.

Keywords

References

  1. 최은하, "고출력 마이크로파의 발진장치 및 전자기 펄스탄 개발동향," 전력전자학회지, 9(1), pp. 20-25, 2004년 2월.
  2. R. Hoad, W. A. Radasky, "Progress in high-altitude electromagnetic pulse(HEMP) standardization," IEEE Transactions on Electromagnetic Compatibility, vol. 55, no. 3, pp. 532-538, Jun. 2013. https://doi.org/10.1109/TEMC.2012.2234753
  3. 정연춘, "고출력 전자기파 방호 제도 도입에 관한 연구," 한국전자파학회논문지, 24(8), pp. 781-790, 2013년 8월. https://doi.org/10.5515/KJKIEES.2013.24.8.781
  4. 국방부, 국방.군사시설기준 전자파 방호시설계기준, DMFC 4-40-70, 2012년 4월.
  5. High-Altitude Electromagnetic Pulse(HEMP) Protection for Ground-Based C4I Facilities Performing Critical, Time-Urgent Missions, Part I - Fixed Facilities, MILSTD-188-125, 2005.
  6. 장태헌 "HEMP 전도성 방해 펄스 전류 주입(PCI) 케이블의 영향 분석," 한국전자파학회논문지, 24(8), pp. 772-780, 2013년 8월. https://doi.org/10.5515/KJKIEES.2013.24.8.772
  7. Electromagnetic compatibility(EMC) - Part 4: Testing and measurement techniques-Section 24: Test methods for protective devices for HEMP conducted disturbance-Basic EMC publication, IEC 61000-4-24, 1997.
  8. 정영경, 신진호, 손규호, 김보성, 윤동기 "테슬라 방식소형 고전압 발생기에 응용을 위한 4분할 적층 원통형 코어에 관한 연구," 대한전기학회 학술대회 논문집, pp. 1338-1339, 2013년 7월.