• 제목/요약/키워드: Pulled out

검색결과 108건 처리시간 0.026초

ISO/TS16949 품질경영시스템 인증에 따른 경영성과에 관한 연구 (A Study on Management Performance by ISO/TS 16949 Quality Management System Certification)

  • 박종영;홍정의;김광수
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 추계학술대회
    • /
    • pp.269-288
    • /
    • 2009
  • After enterprise get a certification in acquisition, the core requirements of ISO/TS 16949 standard is pull out the Performance Indicators by process access approach during the settlement and operation of system, and the pulled key performance indicators classified into the customer intention process, support process and management process and analyzed the effect to the management result. This study conducted with following step. Firstly, preceding research, the literature and investigation analysis about process approach method which is the special characteristics of ISO/TS 16949 standard. Secondly, each process of ISO/TS 16949 standard is classified and deduced the key performance indicators followed process access method. Finally, get a enterprise survey data related to improvement of Performance Indicator and analyzed by SPSS statistical software.

  • PDF

ISO/TS16949 품질경영시스템 인증에 따른 경영성과에 관한 연구 (A Study on Management Performance by ISO/TS 16949 Quality Management System Certification)

  • 박종영;홍정의;김광수
    • 대한안전경영과학회지
    • /
    • 제11권3호
    • /
    • pp.227-237
    • /
    • 2009
  • After enterprise get a certification in acquisition, the core requirements of ISO/TS 16949 standard is pull out the Performance Indicators by process access approach during the settlement and operation of system, and the pulled key performance indicators classified into the customer intention process, support process and management process and analyzed the effect to the management result. This study conducted with following step. Firstly, preceding research, the literature and investigation analysis about process approach method which is the special characteristics of ISO/TS 16949 standard. Secondly, each process of ISO/TS 16949 standard is classified and deduced the key performance indicators followed process access method. Finally, get a enterprise survey data related to improvement of Performance Indicator and analyzed by SPSS statistical software.

CONSIDERATIONS FOR METALLOGRAPHIC OBSERVATION OF INTERGRANULAR ATTACK IN ALLOY 600 STEAM GENERATOR TUBES

  • HUR, DO HAENG;CHOI, MYUNG SIK;LEE, DEOK HYUN;HAN, JUNG HO
    • Nuclear Engineering and Technology
    • /
    • 제47권7호
    • /
    • pp.934-938
    • /
    • 2015
  • This technical note provides some considerations for the metallographic observation of intergranular attack (IGA) in Alloy 600 steam generator tubes. The IGA region was crazed along the grain boundaries through a deformation by an applied stress. The direction and extent of the crazing depended on those of the applied stress. It was found that an IGA defect can be misevaluated as a stress corrosion crack. Therefore, special caution should be taken during the destructive examination of the pulled-out tubes from operating steam generators.

Fixing hair using a hair-fixing sheet: better than hairpins?

  • Hye Mi Lee;Hyeon Hee Lee;Young Cheon Na
    • 대한두개안면성형외과학회지
    • /
    • 제25권1호
    • /
    • pp.48-50
    • /
    • 2024
  • Identifying tumors or wounds on the scalp is difficult because hair blocks the vision during surgery and suturing. In the meantime, we have commonly used hairpins to hold the hair for a clearer view; however, we would like to suggest a new method, a "hair-fixing sheet," consisting of hook-like surface. We applied the two methods, hair-fixing sheets and hairpins, assuming several situations. In these situations, it was possible to fix a wider range or various shapes more conveniently using a hair-fixing sheet than using several hairpins at a similarly low cost. In addition, it was easy to change the hair to be fixed, remove it postoperatively, and prevent the hair from being pulled out, thereby preventing additional postoperative pain.

지반 반력 스프링 시스템을 이용한 강관 합성 말뚝의 수평 지지 특성 평가 (Estimation of the lateral behavior of steel-concrete composite piles using subgrade-reaction spring system)

  • 권형민;이주형;박재현;정문경;곽기석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.388-395
    • /
    • 2009
  • Steel casing used to keep a borehole wall in the construction of drilled shaft increases the vertical and lateral stiffness and strength of pile, but it is usually pulled out or ignored due to the absence of standard or the problem of erosion of steel casing. In order to make use of steel casing as a permanent structure, this study carried out an experimental work for the steel-concrete composite pile. Four types of piles were used to estimate the lateral behavior of piles, which are reinforced concrete pile, steel pile and steel-concrete composite pile with and without reinforcing bar. The subgrade-reaction spring system was developed to simulate the lateral stiffness of soil in laboratory. Also, the composite loading system which can apply the axial and lateral load simultaneously was employed.

  • PDF

비정질 강섬유보강 시멘트복합체의 정역학특성 및 내충격성능 평가를 통한 구조물 적용 가능성 검토 (Investigation on the Applicability of Structures by Evaluating the Static Properties and the Impact Resistance Performance of Amorphous Metallic Fiber Reinforced Cement Composites)

  • 강일수;김규용;이보경;이상규;손민재;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.79-80
    • /
    • 2017
  • This study examined the effect that the amorphous metallic fibers had on the static mechanical properties and the impact resistance of cement composites to those of hooked steel fibers. The hooked steel fiber exhibited pull-out from the matrix after the peak flexural stress was attained, while the amorphous metallic fiber was not pulled out from the matrix, but was instead cut off. In terms of impact resistance, the amorphous metallic fiber reinforced cement composite was found to be more effective at resisting cracking than the hooked steel fiber reinforced cement composite. Therefore, amorphous metallic fiber should be used in fiber reinforced cement composite materials, and for structural materials, and for protection panels.

  • PDF

자기회로의 위상학적 상사성을 이용한 전류제한기 구조에 관한 연구 (The Research for a Structure of Current Limiter using a Phasic Similitude of Magnetic Circuit)

  • 지근양;민경일;이수원;장봉환;문영현
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2128-2135
    • /
    • 2009
  • In this paper, current limiter using a magnetic switching which is based on magnetic flux change in the case of fault is proposed. This current limiter consists of iron-core and three parts of coils. One is the primary coil connected to the power system. Another is the secondary coil wound to the opposite direction of the primary coil's winding. The other is the secondary of the secondary coil which is a movable copper plate winding and located below the secondary coil. In the normal state, the magnetic flux produced in the primary and secondary coils flows to the opposite directions each other and becomes to be canceled out. Therefore the voltages induced between the coils are zero. In the case of a fault, at the moment of a fault occurrence recognition, the switch connected to a secondary coil is opened and the secondary of the secondary coil is pulled out to the outside of the iron-core. Then, magnetic flux becomes to flow through the iron-core. Accordingly, the voltage is induced between the both ends of the primary coil and makes the current reduced. Therefore it is possible to cut off the circuit breaker easily with the proposed current limiter. This paper analyzes the current limiting effects and the detailed results are given.

Ir-192 밀봉선원의 표면오염 방지 (Microscopic Examination of Fracture Particles on the Surface of Ir-192 Sealed Source and Ultrasonic Cleaning)

  • 국일현;박춘득;구자호
    • 방사선산업학회지
    • /
    • 제9권2호
    • /
    • pp.91-102
    • /
    • 2015
  • The iridium disc, generally used in industrial radiography, is examined to find the fracture morphology and fine particles remaining on the shear blank surface. Randomly selected 1,200 discs were observed under a scanning electron microscope tilted more than $45^{\circ}$. Fracture surfaces are classified into three groups: (1) surface fall-out, (2) fracture on the edge and (3) multi-step brittle fracture, which shows the mutual relationship between the fracture morphology and remaining particles. Fracture particles were removed by cleaning the discs in a ultrasonic bath with acetone and collected at the bottom. Removed number of the particles were counted for each different group of fracture surfaces. Followings are conclusions: (1) About 80.5% of discs (966/1,200), have sound plastic shear surfaces with particles remained. (2) About 2% discs accompany surface fall-out's having large particles tens of ${\mu}m$, which is stable not to be pulled out even after the considerably long time of ultrasonic cleaning. (3) About 5% discs contain the fractures on the edge and the particles are removed thoroughly within 30 minutes. (4) 234 discs out of 1,200 discs have multi-step fracture surfaces whose particles never removed in a short period of time but come out very slowly. Such a disc having multiple-step fracture is attributed to the promate cause to the 'leaker'. It is noted here that the discs having mutiple-step fractures should be treated separately with special care, and it is need to study how to treat them.

접착 테이프 박리거동에 미치는 외부효과에 관한 연구 (A Study on External Effects on Peeling-off Behavior of Adhesive Tape)

  • 한원흠;정형식;이문호
    • 접착 및 계면
    • /
    • 제13권1호
    • /
    • pp.9-16
    • /
    • 2012
  • 접착용 테이프 박리거동에 미치는 외부효과를 알아보고, 이를 설명하는 준강체 실린더 체인(semi-rigid body cylinder chain) 모델을 제안하였다. 먼저 평면으로부터 테이프를 떼어낼 때, 테이프의 거동을 정성적으로 파악하고, 이를 토대로 준강체 실린더 체인 모형을 도식화하였다. 그 다음 테이프를 떼어내는 힘에 미치는 여러 요소들(온도, 표면거칠기, 떼어내는 속도, 각도 의존성, 테이프 폭 등)의 효과와 이들의 민감도를 분석하여 동일한 실험 기준조건을 설정하고, 이 조건에서 평면으로부터 테이프를 떼어내는 힘(벡터)의 각도 의존성을 $10^{\circ}$ 간격으로 측정하였다. 실험결과는 본 연구에서 확립한 모형이론과 실험오차범위 내에서 잘 일치하였고, 다른 요소들의 효과는 현상론적 입장에서 정성적으로 잘 설명되었다. 이러한 이유로, 본 결과는 PSA 테이프의 접착력을 시험 평가하는 모델로 활용될 수 있을 것으로 기대된다.

Pull-out bond strength of a self-adhesive resin cement to NaOCl-treated root dentin: effect of antioxidizing agents

  • Khoroushi, Maryam;Kachuei, Marzieh
    • Restorative Dentistry and Endodontics
    • /
    • 제39권2호
    • /
    • pp.95-103
    • /
    • 2014
  • Objectives: This study evaluated the effect of three antioxidizing agents on pullout bond strengths of dentin treated with sodium hypochlorite. Materials and Methods: Root canals of 75 single-rooted human teeth were prepared. Fifteen teeth were irrigated with normal saline for a negative control group, and the remaining 60 teeth (groups 2 - 5) with 2.5% NaOCl. The teeth in group 2 served as a positive control. Prior to post cementation, the root canals in groups 3 - 5 were irrigated with three antioxidizing agents including 10% rosmarinic acid (RA, Baridge essence), 10% hesperidin (HPN, Sigma), and 10% sodium ascorbate hydrogel (SA, AppliChem). Seventy-five spreaders (#55, taper .02, Produits Dentaires S.A) were coated with silica and silanized with the Rocatec system and ceramic bond. All the prepared spreaders were cemented with a self-adhesive resin cement (Bifix SE, Voco Gmbh) in the prepared canals. After storage in distilled water (24 h/$37^{\circ}C$), the spreaders were pulled out in a universal testing machine at a crosshead speed of 1.0 mm/min. Pull-out strength values were analyzed by one-way ANOVA and Tukey's HSD test (${\alpha}$ = 0.05). Results: There were significant differences between study groups (p = 0.016). The highest pullout strength was related to the SA group. The lowest strength was obtained in the positive control group. Conclusions: Irrigation with NaOCl during canal preparation decreased bond strength of resin cement to root dentin. Amongst the antioxidants tested, SA had superior results in reversing the diminishing effect of NaOCl irrigation on the bond strength to root dentin.