• 제목/요약/키워드: Pull-out Behavior

검색결과 192건 처리시간 0.024초

Assessment of pull-out behavior of tunnel-type anchorages under various joint conditions

  • Junyoung Ko;Hyunsung Lim;Seunghwan Seo;Moonkyung Chung
    • Geomechanics and Engineering
    • /
    • 제36권1호
    • /
    • pp.71-81
    • /
    • 2024
  • This study analyzes the pull-out behavior of tunnel-type anchorage under various joint conditions, including joint direction, spacing, and position, using a finite element analysis. The validity of the numerical model was evaluated by comparing the results with a small-scaled model test, and the results of the numerical analysis and the small-scaled model test agree very well. The parametric study evaluated the quantitative effects of each influencing factor, such as joint direction, spacing, and position, on the behavior of tunnel-type anchorage using pull-out resistance-displacement curves. The study found that joint direction had a significant effect on the behavior of tunnel-type anchorage, and the pull-out resistance decreased as the displacement level increased from 0.002L to 0.006L (L: anchorage length). It was confirmed that the reduction in pull-out resistance increased as the number of joints in contact with the anchorage body increased and the spacing between the joints decreased. The pull-out behavior of tunnel-type anchorage was thus shown to be significantly influenced by the position and spacing of the rock joints. In addition, it is found that the number of joints through which the anchorage passes, the wider the area where the plastic point occurs, which leads to a decrease in the resistance of the anchorage.

Improved Modeling of the Effects of Thermal Residual Stresses on Single Fiber Pull-Out Problem

  • Chai, Young-Suk;Park, Byung-Sun;Yang, Kyung-Jun
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.823-830
    • /
    • 2001
  • The single fiber pull-out technique has been commonly used to characterize the mechanical behavior of fiber/matrix interface in fiber reinforced composite materials. In this study, an improved analysis considering the effect of thermal residual stresses in both radial and axial directions is developed for the single fiber pull-out test. It is found to have the pronounced effects on the stress transfer properties across the interface and the interfacial debonding behavior.

  • PDF

돌기형 저항체를 설치한 앵커의 인발저항거동 (Pull-out Resistance Behavior of the Anchor with the Bump Type Resistors)

  • 유민구;이상덕
    • 한국지반공학회논문집
    • /
    • 제33권11호
    • /
    • pp.35-43
    • /
    • 2017
  • 본 연구에서는 정착부 표면에 저항체를 설치한 앵커의 인발거동특성을 모형시험을 통해 규명하였다. 모형시험은 원형의 토조 중앙에 앵커체를 설치한 후 앵커를 등속으로 인발하면서 인발저항력을 측정하였다. 본 연구에서는 앵커형식(저항체 설치 유무), 앵커체 표면의 마찰조건($1/3{\phi}$, $2/3{\phi}$, ${\phi}$)과 돌기형 저항체 개수(1set, 2set, 4set), 돌기형 저항체 높이(0.05d, 0.10d, 0.20d) 등 총 10가지의 조건에 대하여 인발시험을 실시하였다. 인발시에는 일정한 속도(1mm/min)를 유지하였으며, 최대 80mm까지 인발하여 각 조건별 인발하중 및 변위를 측정하였다. 인발시험 결과 확장형 앵커는 마찰형 앵커와 비교하여 최대 인발저항력 뿐만 아니라 잔류 인발저항력도 크게 발생하는 것으로 분석되었다. 돌기형 저항체의 설치개수 증가에 따라 최대 인발저항력이 증가하였으며, 잔류 저항력 비율은 171~591%로 마찰형 앵커에 비해 현저하게 증가하였다.

포화토내 나선형 앵커의 무리효과에 관한 실험적 고찰 (Small Scaled Pull-out Tests on Group Effect of Screw Anchors in Saturated Sand)

  • 김홍택;권영호;박사원;최영하
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.387-394
    • /
    • 2000
  • In the present study, laboratory pull-out tests with screw anchors are carried out to investigate behavior characteristics of underground structures applied uplift seepage forces. Small scaled pull-out tests in sand were conducted under saturated condition. And then, it was observed that the upward displacement as well as the pullout load varied with spacing of the anchor. Also, analyses have been performed with the aim of pointing out the effects of various parameters on the group effect of the screw anchors.

  • PDF

Effects of Steel Fiber Reinforcement and the Number of Hooked Bars at R/C Exterior Joints

  • Choi, Ki-Bong
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.181-189
    • /
    • 1999
  • An experimental study was performed on the Pull-out behavior of 90-deg standard hooks from the exterior beam-column connections. the effects of the number of hooked bars and fiber reinforcement of the joint area were investigated with the following conclusions : (1) Under the pull-out action of hooked bars. the damage and cracking of joint area the number of hooks pulling out from a joint increases; (2) Substitution of the transverse column (confining) reinforcement with steel fibers at the joint region effectively reduces the extent of cracking in exterior joints caused by the pull-out of hooked bars; (3) The pull-out strength and post-peak ductility of hooked bars are adversely influenced by the increase in number of hooks pulling out from an exterior joint. Current hooked bar anchorage design guidelines may be improved by considering the effect of the number of hooked bars on anchorage conditions at the exterior joints; and (4) The strength and ductility of hooked bars under pull-out forces are positively influenced by substituting the conventional confining reinforcement of exterior joints with steel fibers . The application of steel fibers to the exterior joints is an effective technique for improving the anchorage conditions of hooked bars, and also for reducing the congestion of reinforcement in the beam-column connections.

  • PDF

현장인발시험을 통한 제거식 쏘일네일의 거동특성 평가 (Evaluation of Behavior Characteristics of Removable Soil Nails from the Field Pull-Out Tests)

  • 김홍택;강인규;이대형;정성필;박시삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.137-144
    • /
    • 1999
  • Recently a removable soil nail is demanded due to problems beyond of economical and engineering purpose. In this study removable soil nails are developed and field pull-out tests are carried out 16 times in order to analysis pull-out characteristics of the removable soil nail. For the spacing and the installed position of fixed socket, the length of the soil nail, and W/C ratio of cement grout in the removable soil nail, pull-out characteristics of pull-out tests are analyzed. From the pull-out characteristics of removable soil nails, it is found that the spacing of fixed socket and W/C ratio of cement grout are important design parameters.

  • PDF

토질특성에 따른 이동차량의 거동 (Behavior of Traveling Vehicle According to Soil Properties)

  • 박영호;김운영
    • 한국지반공학회지:지반
    • /
    • 제13권2호
    • /
    • pp.125-136
    • /
    • 1997
  • 화강풍화토지반(SP)의 밀도와 함수비 그리고, 점성토지반(ML)의 함수비 변화가 불도저 궤도 차량의 주행성능에 미치는 영향을 알아보기 위하여, 강원도 춘천군 역골지역에서 실물크기의견 인력시험을 실시하였다. 시험결과로부터, 최적견인력거동은 함수비 뿐만아니라 밀도에도 크게 영향을 받음을 알았다. 또한, 본 연구에서는 지반상태에 따라서 변하는 견인력거동의 최적점 결정방법을 제안하였으며, 화강풍화토지반의 밀도에 따른 최적견인력과 최적슬립을 구하였다.

  • PDF

사질토지반에서 수평인발하중을 받는 석션말뚝에 관한 연구 (A Study on Behavior of Horizontal Pull-out Loaded suction pile in Sands)

  • 김진복;박종운;진홍민;권오균
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1120-1131
    • /
    • 2010
  • In this thesis the model tests were performed to the horizontal pull-out characteristics of a suction pile subjected to a pull in sands. For this model tests, soil conditions ($D_r$=65), three pile diameters (D=100, 150, 200mm) and five loading points (h/L=0, 0.25, 0.5, 0.75, 1) were changed. And the experimental results were also compared with those by the theoretical methods. The results by the experimental and theoretical analysis are as follows. The ultimate horizontal pull-out resistance by the model test increased as the loading point (h/L) moved downwards from the pile top, and the maximum value reached at the h/L=0.75. The theoretical ultimate horizontal pull-out resistance by Broms(1964) and Hong(1984) agreed well with that by the model test at h/L=0 and 0.25, but their results overestimated the experimental result at lower part of pile and the differences between the theoretical and experimental results were of great. While the horizontal loading applied at the upper part of pile, the pile moved to the horizontal direction with rotating clockwise. As the loading point moved downwards from the pile top, the rotating angle of pile was smaller.

  • PDF

현장인발시험을 통한 흙-네일의 하중 전이특성에 대한 연구 (A Study on Load Transfer between Soil and Nail Using In-situ Pull-out Tests)

  • 김종수;이장덕;민경준;이송
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.167-174
    • /
    • 1999
  • A Land slide in Granitic Gneiss weathered soil was stabilized successfully with soil nailing using 929mm steel bar. To understand the behavior of load transfer between soil and nail, in-situ pdl-out tests were carried out. The strains of steel bars were measured using strain gauges during pull-out tests. Forces-strain data from laboratory tension tests on steel bar and grouted steel bar were examined to compare with those of the pull-out tests. Comparisons were made between the pull-out test results and laboratory test result to understand load transfer mechanism.

  • PDF

접이식 웨지 장착 강관네일의 현장 인발시험 및 3차원 유한요소해석 (Field Pull-out Test and 3-D FEM Analysis for Steel Pipe Nailing Installed Foldable Wedge)

  • 권교근;최봉혁
    • 대한토목학회논문집
    • /
    • 제29권6C호
    • /
    • pp.313-319
    • /
    • 2009
  • 본 연구에서는 접이식 웨지를 장착한 강관네일의 거동 특성 평가를 위해 현장인발시험 및 3차원 수치해석을 수행하였다. 접이식 웨지를 장착한 강관네일의 현장인발시험 결과 접이식 웨지가 없는 경우에 비해 약 30% 정도의 인발 저항 증진효과가 있는 것으로 평가되었다. 한편, 강관네일의 합리적인 인발거동 분석을 위해 3차원 수치해석에서는 접이식 웨지가 장착 되지 않은 강관네일의 역해석을 통하여 현장 인발거동과 일치하는 네일과 지반사이의 마찰 특성을 평가하고, 이를 접이식 웨지가 장착된 강관네일의 해석에 도입하여 그 거동을 분석하였다. 시행착오를 통한 역해석 결과 그라우트와 지반 사이의 마찰계수(${\mu}$)는 약 1.2 정도가 발휘되는 것으로 평가되었으며, 강관네일의 극한인발저항력은 $$T_L{\sim_=}32$$ tonf으로 접이식 웨지가 장착되지 않은 네일의 $$T_L{\sim_=}24$$ tonf 보다 약 33% 증가하는 것으로 평가되어 현장인발시험결과와 거의 일치하는 것으로 나타났다.