• Title/Summary/Keyword: Pull up

Search Result 258, Processing Time 0.025 seconds

Diffuse Cavernous Hemangioma of the Rectosigmoid Colon - a Case Report - (범발성 해면상 S-결장 및 직장 혈관종 -1 예 보고-)

  • Park, Yong-Geun;Chung, Jae-Hee;Song, Young-Tack
    • Advances in pediatric surgery
    • /
    • v.9 no.2
    • /
    • pp.121-124
    • /
    • 2003
  • Diffuse cavernous hemangioma of the rectosigmoid is a rare lesion usually presented in children and young adult, often with life threatening hemorrhage. The clinical diagnosis is difficult and often delayed because of lack of awareness of the clinical features. We report a case of diffuse cavernous hemangioma of the rectosigmoid in a 12 year old boy who had undergone suture ligation under the impression of hemorrhoid at his age 3. Sphincter saving coloanal pull through procedure were applied as the surgical treatment. Sclerotherapy was needed with recurrent rectal bleeding 6 months after the pull through operation. The patient is well at 12 months follow-up.

  • PDF

A New Isolated Boost Push-Pull Power Conversion Circuit with Distributed Current and Integrated Magnetic Structure (전류 분할 및 통합 자기 구조를 가지는 새로운 승압형 푸쉬-풀 전력 변환 회로)

  • 노정욱;김현수;문건우;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.20-23
    • /
    • 1998
  • An improved current-fed push-pull PWM converter with integrated magnetics is presented. With this improved topology, the design of magnetic elements such as an inductor and a transformer becomes easier than that using the conventional topology, especially when the converter is suffered from an extremely high input current. Since this gives twice the voltage conversion ratio compared to the conventional one, it is also suited for the high voltage step-up power conversion process. The operation of the proposed converter is thoroughly analyzed. Also, the theoretical analysis and experimental results are taken from the laboratory level prototype.

  • PDF

Active-clamp current-fed push-pull converter (능동 클램프를 이용한 전류원 푸쉬풀 컨버터)

  • Kim, Sang-Sik;Kwon, Bong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1006-1007
    • /
    • 2006
  • An active-clamp current-fed push-pull converter for the step-up application is proposed. The proposed converter is composed of active-clamp circuits and a voltage doubler rectifier. Thus, the voltage stress of the main switches is reduced and the output diodes are clamped to output voltage. Moreover, the output diodes can achieve zero current switching (ZCS) by the series resonance between resonant capacitors and leakage inductances. The prototype is designed for 350V/1.5kW with input voltage range $30{\sim}60V$. The theoretical analysis and experimental results are presented.

  • PDF

A Half-VDD Voltage Generator for Low-Voltage DRAM

  • Baek Su-Jin;Kim Tae-Hong;Cho Seong-Ik;Eun Jae-Jeong;Ko Bong-Jin;Ha Pan-Bong;Kim Young-Hee
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.74-76
    • /
    • 2004
  • A Half-VDD Voltage(VHDD) Generator using PMOS pull-up transistor and NMOS pull-down transistor was newly proposed for low-voltage DRAMs. The driving current was increased and the power-on settling time was reduced in the new circuit. The newly proposed VHDD generator worked successfully at VDD at 1.5V and fabricated using 0.18um CMOS twin-well technology.

  • PDF

Test Pattern Genration for Detection of Stuck-Open and Stuck-On Faults in BiCMOS Circuits (BiCMOS 회로의Stuck-Open 고장과 Stuck-On 고장 검출을 위한 테스트 패턴 생성)

  • 신재흥;임인칠
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.1
    • /
    • pp.1-11
    • /
    • 1997
  • A BiCMOS circuit consists of the CMOS part which performs the logic function, and the bipolar part which drives output load. In BiCMOS circuits, transistor stuck-open faults exhibit delay faults in addition to sequential beavior. Also, stuck-on faults enhanced IDDQ (quiscent power supply current) at steady state. In this paper, a method is proposed which efficiently generates test patterns to detect stuck-open faults and stuck-on faults in BiCMOS circuits. The proposed method divides the BiCMOS circuit into pull-up part and pull-down part, and generates test patterns detect faults occured in each part by structural property of the BiCMOS circuit.

  • PDF

A Nickel Micro Switch Operating in a Wide Range of Torsion Angles

  • Kahng, Seong-Joong;Kim, Jae-Hyeok;Kim, Young-Min
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.263-266
    • /
    • 2007
  • We report a nickel optical MEMS switch, being able to rotate through a large angle and to accommodate multiple channels. The proposed optical switch consists of a thin nickel mirror and two torsion springs supporting the mirror. The torsion springs are designed using a finite element method (FEM) such that plastic deformation of the thin nickel is avoided during the large torsion actuation. For switching speed improvement, transient vibration of the released mirror is suppressed by optimizing the mirror design and a fast switching response of $200\;{\mu}s\;(pull-down)/300\;{\mu}s\;(pull-up)$ is demonstrated.

Comparison of physical fitness according to body mass index of Chinese college students (중국 대학생의 체질량지수에 따른 체력 비교)

  • Chen, Fu;Kim, Jung-Hyun;Kim, Ok-ja
    • Journal of Korean Physical Therapy Science
    • /
    • v.28 no.3
    • /
    • pp.53-65
    • /
    • 2021
  • Background: The purpose of this study was to a comparison of physical fitness according to the body mass index (BMI) of Chinese college students. Design: Cross-sectional study. Methods: According to the BMI, the research objects are divided into four types: underweight, normal weight, overweight, and obesity. This research took 26,976 college students who participated in Jiujiang College. It examines BMI, 50m, vital capacity, standing long jump, sitting forward bend, sit-up (female), pull-up (male), 800m (female), 1000m (male) which is to research the correlation between different BMI and other indicators. Results: The physical qualities of students with normal weight are significantly better than those with other BMI groups. Pearson correlation analysis showed that male BMI was positively correlated with vital capacity (r=0.07, p<0.01), 50m (r=0.15, p<0.01) and 1000m (r=0.14, p<0.01), and negatively correlated with standing long jump (r=-0.12, p<0.01), sitting forward bend (r=-0.06, p<0.01) and pull-up (r=-0.13, p<0.01); Female BMI was positively correlated with vital capacity (r=0.03, p<0.01), 50m (r=0.21, p<0.01) and 800m (r=0.18, p<0.01), and negatively correlated with standing long jump (r=-0.07, p<0.01), sitting forward bend (r=-0.11, p<0.01) and sit-up (r=-0.10, p<0.01). Conclusion: Overweight and underweight will affect the physical quality of college students. Students should keep their BMI within the normal range for their health.

Arthroscopic Treatment of Tibial Spine Fracture using Suture Hook and pull-out PDS (Suture Hook과 pull-out PDS를 이용한 경골극 골절의 관절경적 치료)

  • Lee, Young Kuk;Kim, Joon Seok;Sohn, Sung Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.132-137
    • /
    • 1999
  • Displaced tibial spine fractures need the anatomical reduction of the displaced bone fragment to achieve normal range of motion and anterior stability of the knee joint. The purpose of this paper is to describe details of arthroscopic technique using suture hook and pull-out PDS and to evaluate the clinical results. We report 7 cases who underwent arthroscopic reduction and internal fixation using suture hook and pull-out PDS. All cases had fresh fractures generated within 3 weeks. The follow up period was at average 16.6 months. The fracture union was achieved at average 7.4 weeks. Knee exercise was started 2 weeks after the operation. One of the patients, who had combined injury of posterior cruciate ligament and lateral meniscus, showed limitation of knee movement. But he was underwent the arthroscopic fibrolysis at one year later, he returned to normal range of motion. Arthroscopic treatment of displaced tibial spine fracture using suture hook and pull-out PDS showed good results including rigid fixation and early mobilization. Therefore it is thought to be one of the effective operative techniques in treatment of the tibial spine fractures.

  • PDF

Experimental Study on Pull Out Characteristics of Adhesive Anchor (부착식 앵커의 인발 특성에 관한 실험적 연구)

  • Yoo, Sung Won;Jung, Sang-Hwa;Kwak, Ki-Suk;Lee, Ju-Hyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3A
    • /
    • pp.555-563
    • /
    • 2006
  • Recently, many bridges become not only functionally obsolete of bridge deck due to inadequate width but also structurally deficient of substructure due to erosion. In these cases, widening is almost always more economical than complete replacement, and therefore there is a need to make available the results of research and field experience pertaining to the widening of bridge substructure. But, an experimental study for the guarantee of unification between existing and new substructure with adhesive anchor is so insufficient that the development of adhesive anchor system for the unification should be settled promptly. The purpose of the present study is to explore pull out and shear characteristics of adhesive anchor system. For this purpose, several series of concrete specimens have been tested. Major test variables were the bonded length, anchor diameter and anchor slope. The pull out strength, bond stress and shear strength of adhesive faces were measured for the specimens. The present study indicates that the pull out strength increased with more bonded length and more anchor diameter, and that the bond stress decreased with more bonded length and more anchor diameter. The pull out strength and the bond stress increases with more anchor slope and it is considered that the slope of $5^{\circ}$ was more efficient. From the shear tests, it is supposed that anchor diameters more than D19 was proper to the adhesive anchor. Finally, it is expected that both experimental data in these tests and further study including mock-up tests will contribute to the establishment of the unification between existing and new substructure with adhesive anchor.

Comparison of the Effects of Magnetically Controlled Growing Rod and Tradiotinal Growing Rod Techniques on the Sagittal Plane in the Treatment of Early-Onset Scoliosis

  • Erdogan, Sinan;Polat, Baris;Atici, Yunus;Ozyalvac, Osman Nuri;Ozturk, Cagatay
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.577-585
    • /
    • 2019
  • Objective : Comparing the effects of magnetically controlled growing rod (MCGR) and traditional growing rod (TGR) techniques on the sagittal plane in the treatment of early-onset scoliosis (EOS). Methods : Twelve patients were operated using dual MCGR technique in one center, while 15 patients were operated using dual TGR technique for EOS in another center. Patients' demographic characteristics, complications and radiological measurements such as cobb angle, thoracic kyphosis, lumbar lordosis, T1-S1 range (mm), proximal junctional angle, distal junctional angle, sagittal balance, coronal balance, pelvic incidence, sacral slope and pelvic tilt were assessed and compared in preoperative, postoperative and last follow-up period. Results : Age and sex distributions were similar in both groups. The mean number of lengthening in the MCGR group was 12 (8-15) and 4.8 (3-7) in the TGR group. Two techniques were shown to be effective in controlling the curvature and in the increase of T1-S1 distance. In TGR group, four patients had rod fractures, six patients had screw pull-out and four patients had an infection, whereas three patients had screw pull-out and one patient had infection complications in the MCGR group. Conclusion : There was no significant difference between the two groups in terms of cobb angle, coronal and sagittal balance and sagittal pelvic parameters. MCGR can cause hypokyphosis and proximal junctional kyphosis in a minimum 2-year follow-up period. The implant-related complications were less in the MCGR group. However, larger case groups and longer follow-up periods are required for the better understanding of the superiority of one method on other in terms of complications.