• Title/Summary/Keyword: Protective Effectiveness

Search Result 156, Processing Time 0.03 seconds

A Study on the Erosion of Wind Turbine Blade Leading Edge by Rain (강우에 의한 풍력 발전기 블레이드 전연부 침식 시험에 관한 연구)

  • Tae-Won Kim;Ki-Woong Moon;Jin-Hyuk Son;Bo-Jung Kim;Si-Hong Ryu;Chang-Bun Yoon
    • Journal of Wind Energy
    • /
    • v.14 no.3
    • /
    • pp.43-53
    • /
    • 2023
  • To improve AEP, wind turbine blade lengths are increasing every year. As the length of blades increases, the blade tip speed also increases. Because of the increased tip speed, the impact energy between the leading edge and raindrops also increases. The increased impact energy is the primary factor contributing to erosion of the blade's leading edge. Blade leading edge erosion reduces aerodynamic performance, increases repair costs, and causes downtime. Therefore, numerous studies are being conducted on protective solutions and RET systems to prevent and delay erosion of the blade's leading edge. However, few institutions in Korea research protective solutions and RET systems. In this study, we aim to develop a laboratory-scale RET system. The developed RET system was based on the ASTM G73-10 standard. As a result of the RET, it was confirmed that the erosion tendency was similar to that of overseas institutions. In addition, the effectiveness of the RET system was verified by a maximum erosion rate of 0.0023 for an epoxy-based protective solution.

A New Strategy for Service Restoration and Switching Sequence Determination in Distribution Automation Systems

  • Lee, Seung-Jae
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.1
    • /
    • pp.51-57
    • /
    • 1998
  • As DAS becomes a common practice, various operational tools are needed. This paper proposes the new restoration strategy considering the coordination of the protective devices and the generalized method for determining the switching sequence. The effectiveness of the proposed method has been tested on the various real systems.

  • PDF

Effectiveness of droplet protective screens and portable air purifiers against droplet and airborne transmission during conversation (비말 가림막과 휴대형 공기청정기 사용에 의한 대화 중 비말 및 공기전파 저감 효과)

  • Jieun, Heo;Dongho, Shin;Hee-Joo, Cho;Hyun-Seol, Park;Yun-Haeng, Joe
    • Particle and aerosol research
    • /
    • v.18 no.4
    • /
    • pp.87-95
    • /
    • 2022
  • Currently, droplet protective screens (DPSs) are used to prevent the spread of respiratory diseases. As virus particles can maintain their infective in indoor environments, recent studies have investigated the risk of airborne transmission. However, the ability of DPSs to block airborne transmission has not been verified yet. In this study, the preventive ability of DPSs against droplet and airborne transmission was evaluated. Moreover, the effectiveness of a Portable air purifier (PAP) was investigated. According to results, in a simulated room where an infectious person spoke, the DPS blocked more than 90% of the micron-sized droplets (with a diameter larger than 1 ㎛) transmitted to the front of the infectious person. However, sub-micron droplets (with a diameter smaller than 1 ㎛) passed through the DPS and spread in a room. However, the PAP reduced the amount of both micron and sub-micron droplets transmitted to the front of the infectious person. When the PAP airflow direction was set from the DPS surface to the free space near the infectious person, improved prevention against droplet and airborne transmission was recorded. However, airborne transmission was accelerated when the PAP airflow direction was set from the free space to the DPS surface.

Evaluating the Protective Effectiveness of Rubber Glove Materials Against Organic Solvents Upon Repeated Exposure and Decontamination

  • Li-Wen Liu;Cheng-Ping Chang;Yu-Wen Lin;Wei-Ming Chu
    • Safety and Health at Work
    • /
    • v.15 no.2
    • /
    • pp.228-235
    • /
    • 2024
  • Background: Glove reuse poses risks, as chemicals can persist even after cleaning. Decontamination methods like thermal aeration, recommended by US OSHA, vary in effectiveness. Some studies show promising results, while others emphasize the importance of considering both permeation and tensile strength changes. This research advocates for informed glove reuse, emphasizing optimal thermal aeration temperatures and providing evidence to guide users in maintaining protection efficiency. Methods: The investigation evaluated Neoprene and Nitrile gloves (22 mils). Permeation tests with toluene and acetone adhered to American Society for Testing Materials (ASTM) F739 standards. Decontamination optimization involved aeration at various temperatures. The experiment proceeded with a maximum of 22 re-exposure cycles. Tensile strength and elongation were assessed following ASTM D 412 protocols. Breakthrough time differences were statistically analyzed using t-test and ANOVA. Results: At room temperature, glove residuals decreased, and standardized breakthrough time (SBT)2 was significantly lower than SBT1, indicating reduced protection. Higher temperature decontamination accelerated residual removal, with ∆SBT (SBT2/SBT1) exceeding 100%, signifying restored protection. Tensile tests showed stable neoprene properties postdecontamination. Results underscore thermal aeration's efficacy for gloves reuse, emphasizing temperature's pivotal role. Findings recommend meticulous management strategies, especially post-breakthrough, to uphold glove-protective performance. Conclusions: Thermal aeration at 100℃ for 1 hour proves effective, restoring protection without compromising glove strength. The study, covering twenty cycles, suggests safe glove reuse with proper decontamination, reducing costs significantly. However, limitations in chemical-glove combinations and exclusive focus on specific gloves caution against broad generalization. The absence of regulatory directives on glove reuse highlight the importance of informed selection and rigorous decontamination validation for workplace safety practices.

A Study on the Improvement of the Subway Protective Guards System (지하철보안관제도의 활성화 방안에 관한 연구)

  • Lee, Sol-Ji;Lee, Ju-Lak
    • Korean Security Journal
    • /
    • no.49
    • /
    • pp.133-154
    • /
    • 2016
  • The Seoul subway system has one of the highest transport shares in the city of Seoul. A high number of passengers means that a high level of crimes of all kinds occur on the city's subway system. As such, Seoul Metro, created the Subway Protective Guards System in 2009, in an effort to enhance safety on the subway. But this innovative new system did not resolve problems. In fact, many citizens came to question the effectiveness of the new system, as it did not yield tangible results. This study seeks to deduce the problems and activation strategy of the Subway Protective Guards System. An in-depth study was conducted by interviewing subway protective guards who were squad leaders with five or more years of relevant work experience. Semi-structured interview analysis was utilized to evaluate their responses. Specifically, their responses were deduced to identify the strengths and weaknesses internal to the system and the opportunities and threats posed by the environment external to the system. This study presents measures to improve the system based on the aforementioned analysis. Measures for improvement focused on the following areas: the adoption of an education system in response to terror; recruitment and the possibility of becoming a permanent employee; obtaining partial judicial powers; improvement of work environment; and intensifying the promotion of the system.

  • PDF

Wheat Bran and Breast Cancer : Plausibility of the Estrogen Hypothesis

  • Cho, Susan-Sungsoo;Sharon Rickard;Chung, Chin-Eun
    • Nutritional Sciences
    • /
    • v.6 no.3
    • /
    • pp.160-166
    • /
    • 2003
  • To examine the evidence that wheat bran is protective against breast cancer development and that its main mechanism of action is by modulating estrogen metabolism. This review explores the role of different experimental factors on the anticancer effects of wheat bran and the relationship of changes to estrogen metabolism by wheat bran on breast cancer risk The timing of the experimental diets in relation to carcinogen administration, the length of feeding of the experimental diets, and the level of dietary fat had an impact on the effectiveness of different doses of wheat bran in reducing breast carcinogenesis. Wheat bran supplementation resulted in significant reductions in human plasma estrogen levels but not in that of animals tested. The change in excretory metabolism of estrogen by wheat bran feeding in animals was not related to any of the tumor indices measured. The protective effect of wheat bran in breast carcinogenesis is greatest at the promotional phase and when supplemented in a high fat diet. Doses of wheat bran in the 9-12% range in diet have been consistently protective. The inconsistency observed with higher doses of wheat bran may be dependent on the animal model used. Although wheat bran's inhibitory effects on tumor growth may involve changes to estrogen metabolism, the fiber and phytochemical components of wheat bran may also act through estrogen-independent mechanisms. For a better understanding of the effect of wheat bran on breast carcinogenesis, studies comparing the effects of different wheat bran components both alone and in combination need to be performed.

Protection Effects of Surge Protective Devices According to Types of system Groundings (전원계통의 접지방식에 따른 서지보호기의 보호효과)

  • 이복희;이동문;강성만;이수봉
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.66-71
    • /
    • 2003
  • Electronic equipments made from integrated circuits and small-sized semiconductors is protected by surge protective devices(SPDs) such as ZnO varistors, Zener diode and gas discharge tube from lightning overvoltages. However the clamping voltage of SPDs is greatly influenced by the method of installing the SPDs. In this paper, the protective effects of SPDs according to types of system groundings were experimentally investigated. The separate grounding is a particularly undesirable way to install SPDs. The effectiveness of the common grounding point for ZnO varistors is more pronounced than that for gas discharge tubes. The common grounding at the terminal of SPDs is recommended as a best method of installing SPDs.

Electromagnetic Pulse Coupling into Naval Warship and Protective Measures (해군 함정에서의 EMP 영향 및 대책)

  • Yang, Jin-Ho;Nam, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.426-433
    • /
    • 2014
  • The high-altitude electromagnetic pulse(HEMP) generated by a high-altitude nuclear explosion. This paper presents the comparison of electric field penetration in Bell laboratories and IEC 61000-2-9 standard when HEMP source penetrates through Naval Warship conducted coupling path and radiated coupling path. Also we analyze the effects of two kinds of coupling and propose Protective measures. Simulation results confirm IEC 61000-2-9 standard is more strict than the Bell Laboratories standard except for a lower frequency band, so we proposed IEC 61000-2-9 standard as a Naval HEMP standard. Finally, we offer the protective measures such as the shielding coating, Honeycomb ventilation, TVS in order to meet the military criteria.

A Study on the Fluoro-polymer Composite Coatings for Protecting the Corrosion of Fossil-fuel Power Plants

  • Kang, Min Soo;Lee, Byung Seung;Chang, Hyun Young;Jin, Tae Eun;So, Il Soo
    • Corrosion Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.62-67
    • /
    • 2007
  • Several heavy duty coatings at an every kind industry facilities to various systems currently have been applied review to the many industry fields. Corrosion-protective characteristics in the case of novolac epoxy among them and unsaturated polyester have been applied most widely. epoxy and flake heavy duty coatings are applied for such reason in an every kind facilities(stack, FGD, cooler, chemical tank etc) of a fossil-fuel power plants Cases of the fossil-fuel power plants are exposed to more severe corrosion environment compared with other facilities and It is difficult to display the performance of long-term method at apply to be the partial. Our study shows fluoro-polymer composite coating method to overcome of the limit. The comparison did previous method and heavy duty coating about FGD plants most at a corrosion environment among fossil-fuel power plants. Additionally, other facilities examined different heavy duty method. The design mode of fluoro-polymer composite coating according to an every kind facilities show extensive methods that are characteristic revelation of film(top, middle and primer layer) composition of the paint, film thickness in accordance with a facilities corrosion and the corrosion protective effectiveness to come into being use fluoro-polymer composite with heavy duty paint(epoxy).

Studies on the Effectiveness of Ginseng Preparation (인삼(人蔘) 제제(製劑)의 효능(效能)에 관한 연구(硏究))

  • Han, Byung-Hoon;Park, Myung-Hwan;Shin, Sang-Chul
    • Korean Journal of Pharmacognosy
    • /
    • v.15 no.2
    • /
    • pp.98-103
    • /
    • 1984
  • A ginseng preparation consisting of ginseng ext., lycii fructus ext., four vitamins and caffeine was chosen and its efficacy was evaluated with respect to nutritional supplement, antifatigue activity and liver protective action. Animals administered orally in both one-third and three fold doses of the preparation showed no significant increments of their body weights when compared with those of the normal animals, suggesting no supplemental activity. However, the preparation in the above two doses significantly prolonged swimming time to 53 and 63%, respectively. Ginseng and lycii fructus ext. were found to be responsible for the antifatigue activity. And also the preparation significantly inhibited lipid peroxidation of mouse liver after ethanol-induced acute intoxication.

  • PDF