• Title/Summary/Keyword: Protection test

Search Result 2,029, Processing Time 0.034 seconds

In Situ Rockfall Tests for Evaluation of Rockfall Protection Fences (국내 낙석방지울타리의 적정성 파악을 위한 현장 실물 실험 및 설계기준 제시)

  • 구호본;박혁진;이경미;김규한;이재욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.629-634
    • /
    • 2000
  • Rockfall protection fence which is used for mitigation of rockfall hazard, has been constructed without consideration of lithology, height and dip angle of rock slope. However, those factors should be considered for the construction of the protection fence. In addition, the protection fence should be evaluated its performance by in-situ test in order to utilize the fence effectively. This is the first full sized rockfall test in Korea. For this test, the rock cut slope whose height is about 20 m and dip angle is 65 $^{\circ}$ has been chosen. Based on the preliminary simulation procedure, four different concrete balls (0.5 ton, 1.0 ton, 2.0 ton and 5.0 ton) were prepared and four different types of protection fence were constructed. The results of this test will be utilized in the establishment of rockfall protection fence construction manual.

  • PDF

A Report on Test Results of Fusible-Link Type Heat Responsive Links (Fusible Link Type 감열체 성능시험보고)

  • Gwon, O-Seung
    • Fire Protection Technology
    • /
    • s.10
    • /
    • pp.5-8
    • /
    • 1991
  • This report is explained about test results of heat responsive links for fire protection service, such as fire dampers and fire doors, automatic fire suppression systems and so forth. The testing program was progressed divided by two testing items, external appearance test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

Optimal Operation Methods of Protection Devices in Distribution Systems with PV Systems (태양광전원의 연계에 의한 배전계통 보호기기의 최적 운용방안에 관한 연구)

  • Kim, Byeon-Gi;Park, Jae-Beom;You, Kyeong-Sang;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1485-1491
    • /
    • 2011
  • This paper deals with the technical problems for the protection devices, by simulating test facilities of protection coordination for Photovoltaic systems. In order to analyze the operation characteristics for the protection devices in the case that the Photovoltaic systems with bi-directional power supply are located in the feeder, this paper proposes the test facilities composed of model distribution system, protection device and model Photovoltaic systems. By performing the simulation for operation characteristics for the protection devices based on the test facilities, this paper presents the malfunction mechanism for the protection devices. The test results show that this paper is practical and effective for the technical guideline for the Photovoltaic systems.

Performance Test of an Integrated Electronic Protection Device Based Photovoltaic Inverter (지능형 보호기기 적용 태양광 인버터 성능시험)

  • Kim, Eung-Sang;Kim, Seul-Ki;Jeon, Jin-Hong;Ahn, Jong-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1744-1750
    • /
    • 2007
  • This paper addresses grid interconnection tests of a 3kW transformer-less photovoltaic (PV) inverter to verify the effectiveness of the PV inverter and promote its wide use. The 3kW transformer-less PV inverter, which was equipped with intelligent protection and control system, was manufactured. A hardware test bed was constructed for performance tests of the PV inverter. Control performance and grid protection tests were carried out using the test bed. Test results verify the performance of the power control and grid protection functions of the developed transformer-less PV inverter.

Study on the Emergency Protection System of Liquid Rocket Engine (액체로켓엔진 비상보호시스템 연구)

  • Kim, Seung-Han;Han, Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.97-103
    • /
    • 2011
  • This paper describes the main considerations for the development of engine emergency protection system and applications to preliminary engine development tests. Emergency protection system performed its role without failure to shutdown test very quickly for the prevention of development of malfunctioning of test articles, which protected test articles and test facility in all abnormal situation occurred during preliminary engine development test program. This results will be used for the development of engine emergency protection system.

  • PDF

전기체 구조시험을 위한 고성능 과하중 방지 모듈 개발

  • Chae, Dong-Chul;Kim, Sung-Chan;Hwang, Gui-Chul;Sung, Kyung-Jin;Shim, Jae-Yeul;Hwang, In-Hee
    • Aerospace Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.208-216
    • /
    • 2004
  • Advanced overload protection module for full scale airframe structural test was developed by improving the existing overload protection module. When performing the full scale airframe structural test, overload can be applied to the test article due to unexpected situations such as system shutdown, test article failure, and deficiency of design strength. Therefore, the overload protection module is needed for protecting the test article in unexpected overload situations. In this paper, the function of the existing overload protection module was summarized for each component and the problems encountered when using it in structural test were analyzed in addition, the development of advanced overload protection module was described.

  • PDF

Performance Evaluation with Protective Function test of Inverter for Solar Power Generation (태양광발전용 인버터 보호기능시험 성능평가)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

Acoustic test of the payload fairing of Korea satellite launch vehicle (소형 위성 발사체의 페이로드 페어링부에 대한 음향 가진 시험)

  • Park, S.H.;Seo, S.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.220-223
    • /
    • 2007
  • Acoustic test of the payload fairing of Korea satellite launch vehicle was conducted to verify the performance of acoustic protection system installed inside the payload fairing. This paper briefly introduces the acoustic test procedures and its results. Overall 148 dB acoustic loads were exerted on the payload fairing structures which mated with the upper stage structure of the launch vehicle. In order to verify the increase of insertion loss by the acoustic protection system, two kinds of test were performed. One is conducted with acoustic protection system and the other without acoustic protection system. Internal acoustic loads as well as external ones were measured and the measured insertion losses were compared with the requirement. The results showed that the acoustic protection system increases the insertion loss by more than 6 dB above 125 Hz. They also indicated that some design modification of Helmholtz resonator array is required to increase the insertion loss at a cavity resonant frequency.

  • PDF

Development and Application of Digital D.C Protection Relay for the test line of Light Rail Transit (경량전철 시험선로의 디지털 직류보호제어장치 개발 및 적용)

  • JEON Y.J.;KIM S.N.;KIM J.H.;BAEK B.S.;LEE H.D.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1373-1375
    • /
    • 2004
  • This paper presents the design of DC protection Relay for Light Rail Transit system, which is very beginning product in domestic. Protection Function characteristic, principle and I/O interface including interlock signal has been introduced. The protection algorithm and EMC characteristics have been certified by official organization and Type test report has been introduced. Up to date in domestic, the test procedure for DC Protection relay hasn't been established so the new method and test equipment based on IEC regulations are proposed. Finally the product will be proved based on field test.

  • PDF

Factors Affecting Radiation Protection Behaviors among Operating Room Nurses (수술실 간호사의 방사선 방어행위의 영향 요인)

  • Kim, Jin;Kim, Jin Sun;Kim, Hyunlye
    • Korean Journal of Adult Nursing
    • /
    • v.28 no.6
    • /
    • pp.680-690
    • /
    • 2016
  • Purpose: This study was designed to identify knowledge, attitude, environment, and self-efficacy among perioperative nurses in terms of radiation protection and to describe those factors affecting radiation protection behaviors. Methods: The sample was comprised of 128 perioperative nurses who agreed to participate in this descriptive study. Data were collected from a self-administered questionnaire and were analyzed using the t-test, analysis of variance, Mann-whitney U test, Kruskal-Wallis test, Pearson's correlation, and multiple regression analyses. Results: Radiation protection behaviors were significantly different by participant's gender, length of career as a perioperative nurse, educational level and prior experience with radiation protection education. Radiation protection behaviors were significantly correlated with radiation protection environment and self-efficacy in terms of radiation protection behaviors. In the multiple linear regression models, radiation protection environment and self-efficacy on radiation protection behaviors were statistically significant predictors of radiation protection behaviors, which accounted for 50.3% of variance in dependent variable. Conclusion: This study concluded that radiation protective environment in operating room is important to promote radiation protective behaviors and radiation safety management program to enhance self-efficacy is highly recommended.