• 제목/요약/키워드: Prosthesis type

검색결과 250건 처리시간 0.021초

Splinted or Non-splinted: 다수의 인접한 치아 결손부 수복을 위한 임플란트 보철 (Splinted and non-splinted implant-supported restorations : prosthetic considerations for restoring multiple adjacent teeth)

  • 윤형인
    • 대한치과의사협회지
    • /
    • 제54권3호
    • /
    • pp.198-205
    • /
    • 2016
  • The purpose of this paper was to investigate the significance of splinted and non-splinted implant-supported restorations with an internal connection for multiple consecutively missing teeth. Upon examination of the effects of fixture-abutment connection, the distribution of occlusal load was favorable in splinted implant-prosthesis with an external connection, but effect of strain distribution was not significant in splinted implant-prosthesis with an internal connection. In splinted implant-prostheses for short implants, strain distribution was not affected by the method of retention. For cement-retained prostheses, the effect of strain distribution due to splinting was not significant. In clinical studies, non-splinted prostheses with an internal connection for multiple consecutively missing teeth showed high survival rate, mild marginal bone loss, and stable periodontal condition. However, failure to achieve optimal proximal contact between single-unit prostheses may lead to food impaction, and veneer fracture may be inevitable when the framework provides inadequate support in the proximal region. In conclusion, splinted implant-prosthesis is not an indication in all cases, and clinical consideration of its use should be based on the patient's oral condition, such as location and number of implants, formation of proximal contact, canine guidance, existence of parafunctional habit, and oral hygiene, when multiple consecutively missing teeth are replaced by internal connection type implant.

  • PDF

인공관절에 사용되는 UHMWPE의 내마모성 향상에 관한 연구 (An enhancement in wear property of UHMWPE used in joint prosthesis)

  • 김경태;이창우;최재봉;최귀원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.3-6
    • /
    • 1996
  • The Ultra-high molecular weight polyethylene (UHMWPE) is exclusivity used as the articulation component with metal or ceramic materials in artificial joint prosthesis because of its good mechanical properties. In the long term however, wear of UHMWPE causes complex problems and hence causes loosening of He prosthesis. In this study, we tried to enhance the wear property of UHMWPE by attaching a hydrophilic graft on the UHMWPE surface and by improving surface hardness without deteriorating the mechanical properties of UHMWPE. This was achieved by ion implantation and by ${\gamma}$-irradiation to the surface in acrylic acid solution and by photo-polymerization in divinylbenzen (DVB), diallysophthalate (DAIP) solution. The wear test was performed by a wear testing machine of ball-on-disk type devised by the authors. The UHMWPE with hydrophlic surface and increased surface hardness developed by above treatments showed less volumetric wear.

  • PDF

근전위 신호구동형 전동의수의 제어시스템 설계 (Design of Control System for Myoelectric Signal Driving Type Myoelectric Hand Prosthesis)

  • 최기원;이명언;라순길;최규하
    • 전력전자학회논문지
    • /
    • 제12권3호
    • /
    • pp.248-257
    • /
    • 2007
  • 본 논문은 사람의 근육에서 발생하는 근전위 신호를 사용하여 2 자유도를 갖는 전동의수를 구동하기 위한 제어시스템을 제안한다. 근전위 신호를 측정하기 위한 표면 근전위 센서는 근전위 신호의 출력 특성을 이용하여 근전위 센서의 입력부와 회로부를 설계한다. 제어시스템은 전동의수를 구동하기 위하여 두 개의 제어기와 전동의수의 파지력을 측정하기 위한 파지력 센서와 파지한 물체의 미끌림을 감지하기 위한 미끌림 센서로 구성되어 있다. 가상의 근전위 신호를 이용한 실험과 정상인의 실험을 통하여 제안된 제어시스템의 신뢰성을 검증하였다.

구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례 (Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique)

  • 홍용신;박은진;김선종;김명래;허성주;박지만
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.67-73
    • /
    • 2012
  • 최근 디지털 인상채득 시스템이 개발되면서 이를 기존의 CAD/CAM 시스템과 접목한 인레이, 온레이, 크라운이나 간단한 계속가공의치 등의 고정성 보철물의 제작이 활발히 소개되고 있다. 그러나 임플란트 보철에서는 주로 기존의 아날로그식 인상채득 후 이를 스캔하여 제작하는 방법이 사용되어 왔으나, 구강 내 디지털 스캔한 데이터를 이용하여 나사형 보철물을 제작하는 술식은 아직 활발히 이루어지지 않았다. 이에 본 증례보고에서는 6명의 환자를 대상으로 구강 내 스캐너인 iTero를 사용하여 디지털 스캔을시행한후그중다섯명은맞춤형지대주와 시멘트 합착 후 나사형 임플란트 보철물(screw-retained implant prosthesis after cementation, or SCRP)을 제작하였고, 임상적으로 기능과 심미적인 측면으로 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

골유착성 임플랜트 보철물의 캔틸레버 위치와 길이변화에 따른 삼차원 유한요소법적 응력분석 (A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF OSSEOINTEGRATED PROSTHESIS ACCORDING TO THE LOCATION AND LENGTH OF CANTILEVER)

  • 장복숙;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.501-532
    • /
    • 1996
  • This study investigated the effects of cantilever length, location and load condition on stress distribution developed in the implants, prostheses and supporting tissues. The osseointegrated prostheses with two 10mm Branemark implants at 2nd premolar and 1st molar sites with cantilever extensions at 1st premolar, 2nd and 3rd molar sites were constructed. Under 100N, 200N of vertical and $45^{\circ}$ oblique loads at the cantilever pontics, stress distribution patterns and displacement were analyzed with three dimensional finite element method. The results were as follows : 1. The stress was concentrated at the joint of the cantilever pontic and implant superstructure, the neck of implant and the ridge crest near the cantilever But there was little load transfer to the lower supporting tissues of implants. 2. The implant near the cantilever was displaced inferiorly while the implant far from the cantilever was displaced superiorly. In horizontal direction the implants were displaced to the direction where the loads were applied, except the apexes of the implants. 3. In case of anterior cantilever, the stress and displacement were higher than the prosthesis connected with natural tooth. 4. The stress developed in the posterior cantilevered type was higher than in the anterior cantilevered type. The greastest stress was concentrated at the ridge crest near the posterior cantilever. 5. The longer the cantilever, the more the stress was developed and was concentrated at the joint of the cantilever pontic and implant superstructure. 6. Under oblique load, the stress was concentrated at the necks of implants and the ridge crests, but decreased at the joint of the cantilever pontic and implant superstructure than under vertical load.

  • PDF

임프란트로 지지된 하악 켄티레버 보철물의 3차원 유한요소 분석 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MANDIBULAR CANTILEVERED PROSTHESIS SUPPORTED BY IMPLANTS)

  • 조철;신상완;권종진
    • 대한치과보철학회지
    • /
    • 제38권5호
    • /
    • pp.724-743
    • /
    • 2000
  • One of the biggest clinical problems of osseointegrated implant prosthesis is the excessive stress caused by bite forces which are transfered directly into the bone through the osseointegrated implant fixtures. So several biodynamic problems occur when there is an excessive fatigue stress. The factors of stress distribution are the number, kind, position, arrangement of the implants, and the distance between the implants, and the kind, quality of superstructure prosthesis and connection type between the rest implant and the superstructure. Recently, a distal short additional implant, socalled rest implant, is employed to reduced the stresses in conventional cantilevered prostheses. This study was undertaken to analyze the stresses transfered by osseointegrated implant cantilevered prostheses depending upon the number and the position of implants, the presence of rest implant, and the type of their connection. Three dimensional finite element analysis was attempted using ANSIS ver. 5.3 program under IBM INDIGO computer. The results were as follows : 1. The rest implant influenced on the pattern of stress distribution on the anterior area of the mandible and the superstructure. 2. In the group employing the rest implants, the fixed type of connection between the rest implant and the superstructure was more stable than the ball attachment type on the stress distribution. 3. In the group employing the ball attachment between the rest implant and the superstructure, the case with 4-implants(on canine, premolar) was little more stable than the case with 6-implants and the case with 4-implants(on incisor, premolar) on the stress distribution. 4. In the cantilevered group, the case with 4-implants(on incisor, premolar) and the case with 6-implants were more stable than the case with 4-implants(on canine, premolar) on the stress distribution. 5. In all of the group, the case with 6-implants and the fixed type of connection was the most stable and the case with 4-implants (on canine, premolar) was the most unstable on the stress distribution.

  • PDF

인공의수의 능동 제어를 위한 생체 신호 처리에 관한 연구 (A study on bio-signal process for prosthesis arm control)

  • 안영명;유재명
    • 전자공학회논문지 IE
    • /
    • 제43권4호
    • /
    • pp.28-36
    • /
    • 2006
  • 본 연구에서는, 팔의 4가지 운동을 구별할 수 있는 계측 시스템과, 구별된 팔의 운동 위치를 추정할 수 있는 제어 알고리즘에 관하여 기술한다. 먼저 4가지(굽히기와 펴기, 내전과 외전) 운동을 구별하기 위해 굽혀진 정도를 측정할 수 있는 전기 저항 형태의 굽힘 센서를 사용한다. 이 센서를 왼팔의 상완 이두근과 오구완근에 1개씩 부착한다. 부착된 두 개의 센서로부터 출력되는 신호는 증폭기와 필터 등으로 구성된 계측 시스템을 통과한다. 이 시스템에서는 상완이두근에 부착된 센서 신호는 굽히기와 펴기 운동 중에서만 On/OFF 작동을 하도록 하고, 오구완근에 부착된 센서 신호는 모든 운동에 작동하도록 설계하였다. 이렇게 출력된 신호들로부터 4가지 운동은 구별하여 출력하고, 출력된 신호들로부터 팔의 운동 위치를 측정한다. 마지막으로, 제안된 알고리즘의 효용성을 입증하기 위해 RC 서보 모터와 포텐션미터로 구성된 2자유도의 인공팔을 제작하여 실험한다. 실험을 통해 인공 팔의 위치는 모터의 회전 관성, 센서의 노이즈 등으로 실제 팔의 위치와 차이가 발생하였다 이 오차를 감소하기 위해 오차값과 오차의 변화값에 근거한 퍼지 PID 제어기를 사용하였고, 이로써 오차가 5도 이내로 감소되었다.

3차원 유한요소법적 분석을 이용한 5종의첨형 임플랜트에 발생하는 응력의 비교연구 (THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF FIVE DIFFERENT TAPER DESIGN IMPLANT SYSTEMS)

  • 변상기;박원희;이영수
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.584-593
    • /
    • 2006
  • Statement of problem : Dental implant which has been developed gradually through many experiments and clinical applications is presently used to various dental prosthetic treatments. To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately of load support. Therefore, it is essential to give the consideration about the stress analysis of supporting tissues for higher successful rates. Purpose : Recently, many implant manufacturing company produce various taper design of root form implant, the fixture is often selected. However, the stress analysis of taper form fixture still requires more studies. Material and method : This study we make the element models that five implant fixture; Branemark system(Nobel Biocare, Gothenberg, Sweden), Camlog system(Altatec, Germany), Astra system(Astra Tech, Sweden), 3i system(Implant Innovations Inc, USA), Avana system(Osstem, Korea) were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the three-dimension finite element analysis under two loading condition. Results : This study compares the aspect of stress distribution of each system with the standard of Von mises stress, among many resulted from finite element analysis so that this research gets the following results. 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and type of system, cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. under the vertical loading, maximum Von mises stress is more higher in order of Branemark, Camlog, Astra, 3i, Avana. under the horizontal loading, maximum Von mises is more higher in order of Camlog, Branemark, Astra, 3i, Avana.

Numerical modeless of the damage, around inclusion in the orthopedic cement PMMA

  • Mohamed, Cherfi;Smail, Benbarek;Bouiadjra, Bachir;Serier, B.
    • Structural Engineering and Mechanics
    • /
    • 제57권4호
    • /
    • pp.717-731
    • /
    • 2016
  • In orthopedic surgery and more especially in total arthroplastie of hip, the fixing of the implants generally takes place essentially by means of constituted surgical polymer cement. The damage of this materiel led to the fatal rupture and thus loosening of the prosthesis in total hip, the effect of over loading as the case of tripping of the patient during walking is one of the parameters that led to the damage of this binder. From this phenomenon we supposed that a remain of bone is included in the cement implantation. The object of this work is to study the effect of this bony inclusion in the zones where the outside conditions (loads and geometric shapes) can provoke the fracture of the cement and therefore the aseptic lousing of the prosthesis. In this study it was assumed the presence of two bones -type inclusions in this material, one after we analyzed the effect of interaction between these two inclusions damage of damage to this material. One have modeled the damage in the cement around this bone inclusion and estimate the crack length from the damaged cement zone in the acetabulum using the finite element method, for every position of the implant under the extreme effort undergone by the prosthesis. We noted that the most intense stress position is around the sharp corner of the bone fragment and the higher level of damage leads directly the fracture of the total prosthesis of the hip.

치관 보철물 제작에 사용되는 치과용 금속의 변연 적합도 비교 (A comparison of marginal fitness by dental alloys)

  • 김남중;황경숙;박용덕
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.29-40
    • /
    • 2003
  • This study was aimed to verify a comparison by dental alloys upon the marginal fitness of dental prosthesis. Firstly, we waxed up on 45 epoxy resin dies, pressed the margin with hands, and identified the marginal fitness with microscope. And we made a single direct spruing system type of sprue by 3 dental alloys - metal crown alloys, PFM crown alloys, and gold crown alloys - each 15, total 45 waxing up, adjusting W/P ratio and invested the cast ring. Then, we made the dental prosthesis using the electric casting machine. In these processes we followed the manufacturer's instructions, in order to maintain the other conditions from the inner and outer, which included investment and burning out. After we tried on the dental prosthesis on epoxy resin dies, we have got the means of marginal gap at 9 points with same distances, around the cervical line which was checked already, using microscope($\times$300). The results of this study were as follows : 1. Metal crown alloys showed 2.9% better in marginal fitness than PFM crown alloys, and the difference was not statistically significant(P=0.497). 2. Gold crown alloys showed 31.3% better in marginal fitness than Metal crown alloys, and the difference was statistically significant(P=0.004). 3. Gold crown alloys showed 32.4% better in marginal fitness than PFM crown alloys, and the difference was statistically significant(P=0.002). 4. We saw that Gold crown alloys was the best dental alloys in the marginal fitness among the three.(P=0.049).

  • PDF