The Journal of Korean Academy of Prosthodontics (대한치과보철학회지)
- Volume 34 Issue 3
- /
- Pages.501-532
- /
- 1996
- /
- 0301-2875(pISSN)
- /
- 2005-3789(eISSN)
A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF OSSEOINTEGRATED PROSTHESIS ACCORDING TO THE LOCATION AND LENGTH OF CANTILEVER
골유착성 임플랜트 보철물의 캔틸레버 위치와 길이변화에 따른 삼차원 유한요소법적 응력분석
- Jang, Bok-Sook (Department of Prosthodontics, College of Dentistry, Seoul National University) ;
- Kim, Chang-Whe (Department of Prosthodontics, College of Dentistry, Seoul National University) ;
- Kim, Yung-Soo (Department of Prosthodontics, College of Dentistry, Seoul National University)
- Published : 1996.09.01
Abstract
This study investigated the effects of cantilever length, location and load condition on stress distribution developed in the implants, prostheses and supporting tissues. The osseointegrated prostheses with two 10mm Branemark implants at 2nd premolar and 1st molar sites with cantilever extensions at 1st premolar, 2nd and 3rd molar sites were constructed. Under 100N, 200N of vertical and
Keywords
- Osseointegrated prosthesis;
- 3-Dimensional finite element method;
- Load condition;
- Cantilever length and location