Numerical modeless of the damage, around inclusion in the orthopedic cement PMMA |
Mohamed, Cherfi
(Department of Mechanical Engineering, University of Sidi Bel Abbes)
Smail, Benbarek (Department of Mechanical Engineering, University of Sidi Bel Abbes) Bouiadjra, Bachir (Department of Mechanical Engineering, University of Sidi Bel Abbes) Serier, B. (Department of Mechanical Engineering, University of Sidi Bel Abbes) |
1 | Achour, T., Tabeti, M.S.H., Bouziane, M.M., Benbarek, S., Bouiadjra, B.B. and Mankour, A. (2010), "Finite element analysis of interfacial crack behaviour in cemented total hip arthroplasty", Comput. Mater. Sci., 47(3), 672-677. DOI |
2 | Benbarek, S., Bouiadjra, B.A.B., El Mokhtar, B.M., Achour, T. and Serier, B. (2013), "Numerical analysis of the crack growth path in the cement mantle of the reconstructed acetabulum", Mater. Sci. Eng. C, 33(1), 543-549. DOI |
3 | Bouziane, M.M., Bouiadjra, B.B., Benbarek, S., Tabeti, M.S.H. and Achour, T. (2010), "Finite element analysis of the behaviour of microvoids in the cement mantle of cemented hip stem: Static and dynamic analysis", Mater. Des., 31(1), 545-550. DOI |
4 | Christipher, Peter, Ken, Bachus, Marcis, Craig, Higginbotham, (2001), J. Arthroplasty, 16, 2. DOI |
5 | Flitti, A., Ouinas, D. and Sahnoun, M. ( 2009), "Effet de la longueur du col sur le comportement mecanique d'une tige de prothese totale de hanche", 2eme Congres Algerien de Mecanique organise du 16 au 19 Novembre 2009, a Biskra, CAM, 2009. |
6 | Flitti, A., Ouinas, D., Bouiadjra, B.B. and Benderdouche, N. (2010), "Effect of the crack position in the cement mantle on the fracture behavior of the total hip prosthesis", Comput. Mater. Sci., 49(3), 598-602. DOI |
7 | Gearing, B.P. and Anand, L. (2004), "On modeling the deformation and fracture response of glassy polymers due to shear-yielding and crazing", Int. J. Solid. Struct., 41(11), 3125-3150. DOI |
8 | Institute for Human Performance (3217), SUNY Upstate Medical University, 750 East Adams Street, Syracuse, NY 13210, USA journal homepage. |
9 | May-Pat, A., Cervantes-Uc, J.M. and Flores-Gallardo, S.G. (2013), "Essential work of fracture: an approach to study the fracture behavior of acrylic bone cements modified with comonomers containing amine groups", Polym. Test., 32(2), 291-298. DOI |
10 | Merckx, D. (1993), "Les ciments orthopediques dans la conception des protheses articulaires. Biomecanique et biomateriaux", Cahiers d'enseignement de la SOFCOT, Expansion Scientifique Francaise, 44, 67-76. |
11 | Oxborough, R.J. and Bowden, P.B. (1973), "A general critical-strain criterion for crazing in amorphous glassy polymers", Philos. Mag., 28(3), 547-559. DOI |
12 | Stolk, J., Verdonschot, N. and Murphy, B.P. (2004), "Finite element simulation of anisotropic damage accumulation and creep in acrylic bone cement", Eng. Fract. Mech., 71, 513-528. DOI |
13 | Poitout, D., Tropiano, P., Bernat, M. and Moulene, J.F. (1997), "Massive hip prostheses ensheated by allografts", Eur. J. Orthop. Surg. Traumatol., 7(2), 123-126. DOI |
14 | Pustoc'h, A. and Cheze, L. (2009), "Normal and osteoarthritic hip joint mechanical behaviour: a comparison study", Med. Biolog. Eng. Comput., 47(4), 375-383. DOI |
15 | Race, A. and Musculoskeletal, M. (2008), "Modified PMMA cement (Sub-cement) for accelerated fatigue testing of cemented implant constructs using cadaveric bone", J. Biomech., 41(14), 3017-3023. DOI |
16 | Tong, J. and Wong, K.Y. (2005), "Mixed mode fracture in reconstructed acetabulum", Department of Mechanical and design Engineering, University of Portsmouth, Anglesea road, Portsmouth, PO1, Vol. 3. |