• Title/Summary/Keyword: Prosthesis loosening

Search Result 68, Processing Time 0.027 seconds

A new retaining method of cement-retained restoration with linguo-horizontal insertion of fiber post (시멘트 유지형 임플란트 보철물의 신개념 유지 방식: Fiber post의 설측 수평 삽입에 의한 유지력 보완)

  • Yoon, Na Ree;Lee, Richard sungbok;Lee, Suk Won;Ahn, Su Jin;Park, Su Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.71-78
    • /
    • 2017
  • The retaining methods of implant prosthesis were classified into a screw-retained and a cement-retained type. A screw-retained prosthesis has many advantages, such as retrievability, preventing residual cement, while their disadvantages include the possibility of screw loosening and fracture, on the contrary advantages of cement-retained prosthesis are relatively low cost, but they are difficult to retrieve. To combine the advantages of both type, screw-cement retained prosthesis (SCRP) type have been introduced. But they still require ideal implant placement. So we introduce fiber post retained prosthesis without residual cement for preventing soft tissue trouble due to excessive cement.

Clinical evaluation of retained preload and cement washout in screw- and cement-retained implant prosthesis (나사 시멘트 유지형 임플란트 보철물의 잔여 전부하 및 시멘트 파손에 대한 임상평가)

  • Chung, Chae-Heon;Son, Mee-Kyoung;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.301-309
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the clinical performance of screw- and cement-retained implant prosthesis (SCP) design in terms of retained preload of abutment screws and cement washout. Materials and methods: Patients with the partial posterior edentulous areas comprised the study group. Implants were placed, and SCPs were delivered after 3 to 6 months healing. Follow-up examinations were performed. The implant survival rate and the prosthetic success rate were evaluated. The retained preload ratio of abutment screws and the prosthetic decementation ratio were measured. Results: Twenty one SCPs (forty three implants)in twenty patients were followed up to 64 months. All of the implants survived during the follow-up period (mean follow-up: 34 months). The prosthetic success rate was 100 % considering no abutment, screw, porcelain or metal frame fractures, as well as no screw loosening. The retained preload ratio of SCPs at the end of follow-up period was 97.61% (${\pm}16.29$) and the decementation ratio was 9.5 %. Conclusion: Within the limitations of this clinical study, SCP design showed favorable short-term clinical performances in respect of screw loosening and cement washout.

Full mouth rehabilitation of edentulous patient with fixed implant prosthesis (고정성 임플란트 보철물을 이용한 완전 무치악 환자의 구강회복 증례)

  • Shi, Hee-Hyun;Kim, Jong-Jin;Baik, Jin;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.147-156
    • /
    • 2021
  • There are various treatment options such as conventional complete denture, hybrid prosthesis and implant-supported fixed prosthesis for fully edentulous patients. In case of implant-supported fixed prosthesis, compared to removable prosthesis, it is difficult to place the implant in the correct position considering the anatomical contours of the final prosthesis. In this case, a full mouth rehabilitation with implant-supported fixed prosthesis was performed for a patient who required extraction of all remaining teeth due to dental caries and chronic periodontitis. In the implant placement stage, the implant was placed in the desired position using a surgical guide fabricated considering the anatomical contours of the final prosthesis, and the function and esthetics were evaluated through correction and re-fabrication of the fixed provisional restoration. A final restoration of porcelain fused to gold prosthesis was delivered to the patient based on the provisional restoration. To cope with complications such as loosening of screws and fracture of porcelain, a screw-retained type prosthesis was fabricated for the posterior part and a screw-cement-retained type prosthesis for the anterior part. As a result, the patient showed an improved prognosis in terms of functional and esthetics after the final prosthesis was delivered.

An enhancement in wear property of UHMWPE used in joint prosthesis (인공관절에 사용되는 UHMWPE의 내마모성 향상에 관한 연구)

  • Kim, K.T.;Lee, C.W.;Choi, J.B.;Choi, K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.3-6
    • /
    • 1996
  • The Ultra-high molecular weight polyethylene (UHMWPE) is exclusivity used as the articulation component with metal or ceramic materials in artificial joint prosthesis because of its good mechanical properties. In the long term however, wear of UHMWPE causes complex problems and hence causes loosening of He prosthesis. In this study, we tried to enhance the wear property of UHMWPE by attaching a hydrophilic graft on the UHMWPE surface and by improving surface hardness without deteriorating the mechanical properties of UHMWPE. This was achieved by ion implantation and by ${\gamma}$-irradiation to the surface in acrylic acid solution and by photo-polymerization in divinylbenzen (DVB), diallysophthalate (DAIP) solution. The wear test was performed by a wear testing machine of ball-on-disk type devised by the authors. The UHMWPE with hydrophlic surface and increased surface hardness developed by above treatments showed less volumetric wear.

  • PDF

A STUDY ON THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE STRESSES ACCORDING TO THE CURVATURE OF ARCH AND PLACEMENT OF IMPLANTS (악궁의 만곡도 및 임플랜트 위치에 따른 삼차원적 유한요소 응력분석)

  • Lee, Don-Oh;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.98-129
    • /
    • 1995
  • The purpose of this study was to evaluate how mandibular implant-supported fixed complete prosthesis, implant and mandible responded mechanically, according to curvature of arch, number and location of fixture, and amounts of load. The shape of mandibular arch was tapered or square form and, 4 or 6 fixtures were implanted in each arch model. A vertical load of 10kg was applied at the center of prosthesis and a vertical load of 20kg was applied at the location of the 10mm or 20mm cantilever posterior to the most distal implant. Three-dimensional finite element analysis was performed for stress distribution and deflection using commercial software(ABAQUS program) for Sun-SPARC Workstation. The results were as follows : 1. The case square arch form was more stable to compare with that of tapered arch form in respect of stress distribution and displacement under vertical load on the center of prosthesis. 2. 6-implants cases were more stable than 4-implants cases for decreasing bending torque under vertical load on the center of prosthesis. 3. Under vertical load on cantilever extension, the case of 10mm long cantilever was more stable than that of 20mm long cantilever in respect of stress distribution and displacement. 4. Under vertical load on cantilever extension, 6-implants cases had a tendency to reduce displacement and to increase the reaction force of supporting point due to increasing of the bending stiffness of the prosthesis than 4-implant case. 5. When the ends of 10mm or 20mm long cantilever were loaded, the most distal implant was under compressive stress but the second most distal implant was under the highest tensile stress and the remaining implants were under varying tensile stress. 6. Because 6-implants cases had smaller displacement than 4-implants cases, 6-implants cases were more favorable in respect of prevention of screw loosening under repeated loadings.

  • PDF

Effects of Ginsenosides Rg1 on Osteoblasts Cultured with Ti Particles

  • Lin, Yu;Wu, Yinsheng;He, Jiacheng;Huang, Yunmei;Lin, Yanping
    • Biomolecules & Therapeutics
    • /
    • v.20 no.1
    • /
    • pp.75-80
    • /
    • 2012
  • The aim of this study was to explore the role and effect of ginsenosides Rg1 on osteoblasts cultured with Ti particles. Osteoblasts from neonatal rats were cultured with particles and different doses of Rg1, the main active ingredient in ginsenosides Rg1. We found that the COX-2, $PGE_2$, TNF-${\alpha}$, IL-1, and IL -6 concentrations in the medium of cells cultured with Ti particles significantly increased as compared with that of the control cells (p<0.05 or p<0.01). In addition, cells cultured with Ti particles alone exhibited the highest concentrations of these molecules. The $PGE_2$, TNF-${\alpha}$, IL-1, and IL-6 levels in the medium of cells cultured with Rg1 were in between those of the control cells and the cells cultured with Ti particles alone. The IL-1ra level in the group cultured with Ti and medium-dose Rg1 was the highest followed by the cells cultured with Ti and high-dose Rg1 and those cultured with Ti and low-dose Rg1 (p<0.05). In conclusion, ginsenosides can reduce the levels of infl ammatory cytokines produced by osteoblasts on induction with Ti particles and can prevent prosthesis loosening.

Numerical modeless of the damage, around inclusion in the orthopedic cement PMMA

  • Mohamed, Cherfi;Smail, Benbarek;Bouiadjra, Bachir;Serier, B.
    • Structural Engineering and Mechanics
    • /
    • v.57 no.4
    • /
    • pp.717-731
    • /
    • 2016
  • In orthopedic surgery and more especially in total arthroplastie of hip, the fixing of the implants generally takes place essentially by means of constituted surgical polymer cement. The damage of this materiel led to the fatal rupture and thus loosening of the prosthesis in total hip, the effect of over loading as the case of tripping of the patient during walking is one of the parameters that led to the damage of this binder. From this phenomenon we supposed that a remain of bone is included in the cement implantation. The object of this work is to study the effect of this bony inclusion in the zones where the outside conditions (loads and geometric shapes) can provoke the fracture of the cement and therefore the aseptic lousing of the prosthesis. In this study it was assumed the presence of two bones -type inclusions in this material, one after we analyzed the effect of interaction between these two inclusions damage of damage to this material. One have modeled the damage in the cement around this bone inclusion and estimate the crack length from the damaged cement zone in the acetabulum using the finite element method, for every position of the implant under the extreme effort undergone by the prosthesis. We noted that the most intense stress position is around the sharp corner of the bone fragment and the higher level of damage leads directly the fracture of the total prosthesis of the hip.

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.6
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

A 10-year retrospective study on the risk factors affecting the success rate of internal connection implants after prosthetic restoration (내부연결 임플란트의 보철 수복 후 성공률에 미치는 위험요소에 관한 10년간의 후향적 연구)

  • Seoin Lee;Min-Jeong Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.113-124
    • /
    • 2023
  • Purpose. The purpose of this study is to help increase the success rate by analyzing the types and characteristics of implant prosthesis and the survival rate. Materials and methods. Among implants placed between 2011 and 2020 at Sanbon Dental Hospital, College of Dentistry, Wonkwang University, a case restored by a prosthetic surgeon was investigated for the characteristics and correlation of failure. The causes of failure were classified as failure of osseointegration, peri-implantitis, fixture fracture, abutment fracture, screw fracture, screw loosening, prosthesis fracture, and loss of prosthesis retention. Prosthetic method, cantilever presence, placement location, etc. were analyzed for their correlation with implant failure. Results analysis was derived through Chi-square test and Kaplan-Meier survival analysis using SPSS ver 25.0 (IBM, Chicago, IL, USA). Results. A total of 2587 implants were placed, of which 1141 implants were restored with Single Crown and 1446 implants with Fixed Partial Denture, and the cumulative survival rate was 88.1%. The success rate of SC was 86.2% (984) and the success rate of FPD was 89.6% (1295), showing statistically significant differences, among which factors that had significant differences were abutment fracture, screw fracture, and screw loosening (P < .05). Conclusion. As a result of the 10-year follow-up, more failures occurred due to biomechanical factors than biological factors. Further studies on the success of implants will be needed in the future.