• Title/Summary/Keyword: Problems of vibration

Search Result 1,391, Processing Time 0.025 seconds

Comparison of Assessment method of Blast Vibration (발파 진동 평가의 문제점과 개선방안)

  • Chang, Seo-Il;Lee, Jae-Won;Kim, Hyung-Kon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.357.2-357
    • /
    • 2002
  • The blast vibration can generate occupants dissatisfy as well as damage of physics nearby building. Then blast vibration estimation issue important problems. But, now blast vibration prediction inside-outside country not established objective method according to blast number to express magnitude of vibration. In this study, Our propoes show our country problem of blast vibration about blast vibration measurement and this problems be able to find improve method. (omitted)

  • PDF

A Case Study on High Vibration in a Condensate Pump for Combined Cycle Power Plants (복합 화력 Condensate Pump 의 고진동 사례 분석 및 대책)

  • 최성필;류석주;하현천
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.510-513
    • /
    • 2001
  • Several kinds of vibration problems have been frequently encountered in industrial vertical pumps in spite of their widespread use for long time. In fact, vibration problems of the vertical pumps are so complicated and difficult with compared to those of the horizontally mounted pumps that more careful attention should be taken for solving the vibration problems. This paper introduces a case study experienced from troubleshooting for excessive vibration occurred in a vertical-type condensate pump for combined cycle power plants. Subsynchronous whirl vibration was caused by the instability of the guide bearing whose lubricant is water. A newly modified guide bearing has solved the vibration problem, which should be the best countermeasure.

  • PDF

Eight-node field-consistent hexahedron element in dynamic problems

  • Rajendran, S.;Prathap, G.
    • Structural Engineering and Mechanics
    • /
    • v.8 no.1
    • /
    • pp.19-26
    • /
    • 1999
  • Superior performance of field consistent eight-node hexahedron element in static bending problems has already been demonstrated in literature. In this paper, its performance in free vibration is investigated. Free vibration frequencies of typical test problems have been computed using this element. The results establish its superior performance in free vibration, particularly in thin plate application and near incompressibility regimes, demonstrating that shear locking, Poisson's stiffening and volumetric locking have been eliminated.

Comparison of Assessment method of Blast Vibration (발파 진동 평가의 문제점과 개전방안)

  • Chang, Seo-Il;Lee, Jae-Won;Kim, Hyung-Kon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.553-558
    • /
    • 2002
  • The blast vibration can generate occupants dissatisfy as well as damage of physics nearby building. Then blast vibration estimation issue important problems. But, now blast vibration prediction inside-outside country not established objective method to express magnitude of vibration according to blast number. In this study, Our propose show our country problem of blast vibration about blast vibration measurement and this problems be able to find improve method.

  • PDF

Analysis of High Vibration in Nuclear Turbine-Generator (원자력 발전소 터빈-발전기 고진동 저감에 대한 고찰)

  • Lee, Woo-Kwang;Ko, Woo-Sig;Kim, Kye-Yean;Koo, Jae-Raeyang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.46-50
    • /
    • 2007
  • The nuclear power plant's turbine-generator system had been suffered form some problems, such as high shaft vibration, generator casing crack, stator coil water leakage, high $H_2$ gas consumption rate. Those kinds of problems were related to high vibration. So nuclear plant decided to replace generator in order to reduce rotor high vibration and high thermal sensitivity. A series of effort to reduce turbine-generator vibration was carried out as followings, first of all, replacement of generator, analysis of turbine-generator vibration, LP B rotor shop balancing, improvement of LP B/Gen coupling run-out, improvement of Generator basement and field balancing. Finally the nuclear turbine-generator's shaft vibration was reduced below $60{\mu}m$ from over $200{\mu}m$ which is very excellent vibration in nuclear turbine-generator in Korea.

  • PDF

A Study on the Dynamic Behavior and Comparative Analysis of a Suspension Type Pulsator/Drum Type Washing Machine (현가형 펄세이터 세탁기와 드럼형 세탁기의 동특성 해석 및 비교 분석)

  • 최진영;이종민;이주상;박노철;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1134-1139
    • /
    • 2003
  • Vibration problems are an intrinsic characteristic in a washing machine owing to rotation working mechanism. Therefore, a right comprehension of working principle and the analysis on dynamic behavior of a washing machine is essential to design anti-vibration or vibration reduction. In this paper, we choose two kinds of a washing machine: a suspension type pulsator/drum type washing machine. Each the structure and working principle of a washing machine is discussed briefly and the dynamic behavior of it is investigated, then, the vibration detection problems of transient or excessive vibration is tented in each category. Some vibration experimented results in a washing machine are presented also.

  • PDF

Vibration Transmission of Plate-Beam Structure having discontinuity (평판과 보의 연성구조물의 진동에너지 전달특성 분석에 관한 연구)

  • 이형택;김정태
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.391-395
    • /
    • 1997
  • The transmission of sound and vibration through structures is of interest in many noise control problems, including architectural acoustics, sound transmission through air craft, spacecraft and ship, and the transmission of noise through machinery and engine enclosures. Statistical Energy Analysis provides a simple and accurate method of approaching these problems. In this paper, comparing the measured coupling loss factor of plate-beam with measured coupling loss factor of mass on the junction will be inspected.

  • PDF

Research on the Noise and Vibration of Mechanical Equipments in Apartment Buildings (공동주택 설비장비의 소음.진동 실태조사)

  • Kim, Myung-Jun;Kim, Heung-Sik;Kim, Ha-Geun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.157-164
    • /
    • 2000
  • A mechanical equipment room with various equipments may be the largest source of noise and vibration. Without sufficient consideration for noise and vibration control in the phase of designing, it causes some problems after completing construction or enormous cost necessary to correct the problems. Therefore, it is essential to consider the method of noise and vibration control, but the systematic guideline of noise and vibration is not provided yet. This study aims to investigate the actual condition of noise and vibration generated from mechanical equipments in apartment buildings, for providing the guideline of its control.

  • PDF

Force Limited Vibration Tests of Micro-Satellites (힘제한 방법을 이용한 소형 위성의 진동시험)

  • 김영기;김홍배;김경운;우성현;김성훈;문상무
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.446-451
    • /
    • 2004
  • Over testing problems of satellites and theirs components have been issued due to their effects on satellite development cost and schedule. Force limited vibration tests were introduced as solution of the problems in 1980s. Over testing phenomena occurs due to the lack of similarity on interface impedance. Force limited vibration tests control interface force to simulate actual interface impedance. In this research, force limited vibration tests are applied on two satellites environmental tests. Force limits are calculated by using TDFS method and Semi-Empirical method. Four force sensors are employed to control interface force. The tests prove that force limited control reduced maximum interface acceleration in order of 3.

  • PDF

Development of Pre-assessment Technique for Environmental Impact of Urban Subway Vibration on Newly Planned Buildings (도시지하철 진동이 신축예정 건축물에 미치는 영향에 대한 사전환경평가 기법개발)

  • 박상규;이홍기;박원형
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1197-1200
    • /
    • 2003
  • Urban subways usually make environmental problems because subway vibrations are transmitted to building structures. However, when the buildings are designed, vibrations due to subway are not usually considered in advance. This results in many environmental vibration problems after buildings are constructed. This study was carried out to set up and evaluate a pre-assessment technique for the environmental impact of urban subway vibration on newly planned buildings near a subway line. for this purpose, semi-emperical method was set up and vibration measurements were made on site in accordance with construction schedule. Computer simulation was also performed using ANSYS software to predict the building vibration and compared with the measured results for evaluation of the pre-assessment technique.

  • PDF