Analysis of High Vibration in Nuclear Turbine-Generator

원자력 발전소 터빈-발전기 고진동 저감에 대한 고찰

  • 이우광 (한국전력공사 전력연구원) ;
  • 고우식 (한국전력공사 전력연구원) ;
  • 김계연 (한국전력공사 전력연구원) ;
  • 구재량 (한국전력공사 전력연구원)
  • Published : 2007.05.10

Abstract

The nuclear power plant's turbine-generator system had been suffered form some problems, such as high shaft vibration, generator casing crack, stator coil water leakage, high $H_2$ gas consumption rate. Those kinds of problems were related to high vibration. So nuclear plant decided to replace generator in order to reduce rotor high vibration and high thermal sensitivity. A series of effort to reduce turbine-generator vibration was carried out as followings, first of all, replacement of generator, analysis of turbine-generator vibration, LP B rotor shop balancing, improvement of LP B/Gen coupling run-out, improvement of Generator basement and field balancing. Finally the nuclear turbine-generator's shaft vibration was reduced below $60{\mu}m$ from over $200{\mu}m$ which is very excellent vibration in nuclear turbine-generator in Korea.

Keywords