• Title/Summary/Keyword: Probe current

Search Result 568, Processing Time 0.032 seconds

Relative Error Analysis for Measuring Value of Ground Resistance according to Position Variation of Potential Probe) (전위보조전극의 위치변화에 따른 접지저항 측정값의 상대오차분석)

  • Gil, Hyoung-Jun;Kim, Dong-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.96-102
    • /
    • 2009
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance with the fall-of-potential method are described and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error for measuring value of ground resistance due to the position of the potential probe, ground resistance were measured in case that the distance of current probe was fixed at 50[m] and the distance of potential probe was located from l0[m] to 50[m]. Also, the potential probe was located at 30[$^{\circ}$], 45[$^{\circ}$], 60[$^{\circ}$], 90[$^{\circ}$] and 180[$^{\circ}$]. As a consequence, relative error decreased with increasing the distance of potential probe and decreasing the angle between current probe and potential probe. The results could be help to determine the position of potential probe when the ground resistance was measured at grounding system.

Dual Core Differential Pulsed Eddy Current Probe to Detect the Wall Thickness Variation in an Insulated Stainless Steel Pipe

  • Angani, C.S.;Park, D.G.;Kim, C.G.;Kollu, P.;Cheong, Y.M.
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.204-208
    • /
    • 2010
  • Local wall thinning in pipelines affects the structural integrity of industries like nuclear power plants (NPPs). In the present study, a pulsed eddy current (PEC) differential probe with two excitation coils and two Hall-sensors was fabricated to measure the wall thinning in insulated pipelines. A stainless steel test sample was prepared with a thickness that varied from 1 mm to 5 mm and was laminated by plastic insulation to simulate the pipelines in NPPs. The excitation coils in the probe were driven by a rectangular current pulse, the difference of signals from two Hall-sensors was measured as the resultant PEC signal. The peak value of the detected signal is used to describe the wall thinning. The peak value increased as the thickness of the test sample increased. The results were measured at different insulation thicknesses on the sample. Results show that the differential PEC probe has the potential to detect wall thinning in an insulated NPP pipelines.

Characterization of oxygen plasma by using a langmuir probe in the inductively coupled plasma (정전 탐침을 이용한 유도 결합형 반응기에서 발생하는 산소 플라즈마의 특성연구)

  • 김종식;김곤호;정태훈;염근영;권광호
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.4
    • /
    • pp.428-435
    • /
    • 2000
  • Negative ion generation in an inductively coupled oxygen plasma was investigated by using a Langmuir probe. It was observed that the probe current ratio of the positive ion saturation current and the negative current which is consisted of the electron current and the negative ion current, and also the potential difference between the floating potential and plasma potential vary with the RF input power and more sensitively with the operating pressure, respectively. Results show that the operating condition to achieve the maximum probe current ratio and the minimum potential difference shift from the low pressure region to the high pressure regions with increasing the input power. It implies that the generation of the negative oxygen ions increases and the recombination of the positive and negative ions are enhanced in the plasma.

  • PDF

Electron Density Measurement of Inductively Coupled Plasma Using Langmuir Probe (Langmuir Probe를 이용한 유도결합형 플라즈마의 전자 밀도 측정)

  • Lee, Young-Hwan;Jo, Ju-Ung;Kim, Kwang-Soo;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1111-1114
    • /
    • 2003
  • In this paper, electrical characteristics of inductively coupled plasma in an electrodeless fluorescent lamp were investigated using a Langmuir probe with a variation of argon gas pressure. The RF output was applied in the range of $5{\sim}50W$ at 13.56MHz. The internal plasma voltage of the chamber and the probe current were measured while varying the supply voltage to the Langmuir probe in the range of $-100V{\sim}+100V$. When the pressure of argon gas was increased, electric current was decreased. There was a significant electric current increase from l0W to 30W. Also, when the RF power was increased, electron density was increase. This implies that this method can be used to find an optimal RF power for efficient light illumination in an electrodeless fluorescent lamp.

  • PDF

A Galvanic Sensor for Monitoring the External and Internal Corrosion Damage of Buried Pipelines

  • Choi, Yoon-Seok;Kim, Jung-Gu;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.4 no.5
    • /
    • pp.178-190
    • /
    • 2005
  • In order to develop a new corrosion sensor for detecting and monitoring the external and internal corrosion damage of buried pipeline, the electrochemical property of sensors and the correlation of its output to corrosion rate of steel pipe, were evaluated by electrochemical methods in two soils of varying resistivity (5,000 ohm-cm, 10,000 ohm-cm) and synthetic tap water environments. In this paper, two types of galvanic probes were manufactured: copper-pipeline steel (Cu-CS) and stainless steel-pipeline steel (SS-CS). The corrosion behavior in synthetic groundwater and synthetic tap water for the different electrodes was investigated by potentiodynamic test. The comparison of the sensor output and corrosion rates revealed that a linear relationship was found between the probe current and the corrosion rates. In the soil resistivity of $5,000{\Omega}-cm$ and tap water environments, only the Cu-CS probe had a good linear quantitative relationship between the sensor output current and the corrosion rate of pipeline steel. In the case of $10,000{\Omega}-cm$, although the SS-CS probe showed a better linear correlation than that of Cu-CS probe, the Cu-CS probe is more suitable than SS-CS probe due to the high current output.

Study on Characteristics of Eddy Current Array Coil Operated in Transmit-Receive Mode and Surface Inspection Using This Probe (송수신 모드 배열 코일 와전류 탐촉자의 특성 연구 및 이를 이용한 표면검사)

  • Lee, Tae-Hun;Jee, Dong-Hyun;Cho, Chan-Hee;Kim, In-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.21-28
    • /
    • 2017
  • Eddy current array (ECA) technology provides the ability to electronically scan without mechanical scanning for a footprint of probe that consists of several eddy current coils arranged side-by-side and two dimensionally. Compared to single-coil eddy current technology, the ECA technology has a higher inspection speed and reliability because a large area can be covered in a single-probe pass and the obtained images can facilitate data interpretation. In this study, we developed an eddy current array probe with $2{\times}16$ coil arrays and a multiplexer that can select transmit-receive coils sequentially and operate in transmit-receive mode. Surface inspection was performed using this probe for specimens that had various flaws and the characteristics of transmit-receive mode ECA technology was studied through an analysis of the obtained eddy current signals and C-scan images.

마이크로플라즈마 전류 스위치 및 응용

  • Chae, Gyeol-Yeo;Kim, Myeong-Min;Mun, Cheol-Hui;Lee, Sang-Yeon;Lee, Seung-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.433-433
    • /
    • 2010
  • A microplasma current switch (MPCS) for a device operated in a current mode like organic light-emitting diodes (OLEDs), which features matrix addressability and current switching, is presented as well as its architecture and operational principle. The MPCS utilizes the intrinsic memory and conductivity of plasmas to achieve matrix addressability and current switching. We have fabricated a $100\;mm\;{\times}\;100\;mm$ MPCS panel in which its cell pitch is $1080\;{\mu}m\;{\times}\;1080\;{\mu}m$. The matrix addressability and current switching were verified. In addition, the current-voltage (I-V) characteristic of the unit cell was measured when plasmas were ignited. In principle, the scheme of the MPCS is equivalent to that of a double Langmuir probe diagnosing plasma parameters except for their relative dimensions to a plasma volume. Accordingly, the I-V characteristic was analyzed by a double Langmuir probe theory, and the plasma density and electron temperature were estimated from the I-V curve using a collisional double Langmuir probe theory.

  • PDF

Characteristic Analysis of Eddy Current Array Probe Signal in Combo Calibration Standard Tube Using Electromagnetic Numerical Analysis (전자기 수치해석을 이용한 표준보정시험편의 배열형 와전류 탐촉자 신호 특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.330-337
    • /
    • 2010
  • In this paper, 3-dimensional electromagnetic numerical analysis is performed about the eddy current(EC) array probe characteristic which is the next generation probe for accurate diagnosis of steam generator(SG) in nuclear power plants(NPPs). ASME(American Society of Mechanical Engineers) Standard and X-probe combo calibration standard tube are selected for acquisition of eddy current testing(ECT) signals and this result of compared with the real test signals for reasonability of result. Based on the analysis result of calibration standard tube, ECT signals that are about the defects of pitting, stress corrosion cracking(SCC), multiple SCC and wear is obtained. Material of specimen was Inconel 600 which is usually used for SG tubes in NPPs. The operation frequency of 300 kHz were used. The signal characteristics could be observed according to the various defects. The results in this paper can be helpful when the ECT signals from EC array probe are evaluated and analyzed.

Electron Density Measurement of Inductively Coupled Plasma by Ar Gas Pressure (Ar 가스 압력에 따른 유도결합형 플라즈마의 전자 밀도 측정)

  • 이영환;김광수;조주웅;박대희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.508-511
    • /
    • 2003
  • In this paper, electrical characteristics of inductively coupled plasma in an electrodeless fluorescent lamp were investigated using a Langmuir probe with a variation of argon gas pressure. The RF output was applied in the range of 5 ∼ 50 (W) at 13.56 (MHz). The internal plasma voltage of the chamber and the probe current were measured while varying the supply voltage to the Langmuir probe in the range of -100 (V) ∼+100 (V). When the pressure of argon gas was increased, electric current was decreased. There was a significant electric current increase from l0W to 30 〔W〕. Also, when the RF power was increased, electron density was increase. This implies that this method can be used to find an optimal RF rower for efficient light illumination in an electrodeless fluorescent lamp.

Analysis of the Local Properties in GdBCO and YBCO Coated Conductors using Low-temperature Scanning Laser and Hall Probe Microscopy (저온 주사 레이저 및 홀소자 현미경을 이용한 GdBCO와 YBCO 초전도 선재의 국소적 특성 분석)

  • Park, S.K.;Ri, H.C.
    • Progress in Superconductivity
    • /
    • v.13 no.3
    • /
    • pp.169-177
    • /
    • 2012
  • Distribution of the local properties in GdBCO and YBCO coated conductors was investigated using Low-temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). We prepared GdBCO and YBCO coated conductors to study the spatial distribution of the current density in a single bridge. Inhomogeneity of the ${T_c}^{max}$ in the bridge was analyzed from experimental results of Scanning Laser Microscopy (SLM) near the superconducting transition. The local transport and screening current in the bridge were also investigated using Scanning Hall Probe Microscopy (SHPM). A series of line scans of SLM of the GdBCO and YBCO sample showed that lines with more inhomogeneous distributions of ${\delta}V$ had more inhomogeneous distributions of ${T_c}^{max}$. The defect of the superconducting layer of the GdBCO sample caused by damage to the substrate affected the current flow. And we could analyze the redistribution of the current density using SLM and SHPM.