• Title/Summary/Keyword: Pressurization

Search Result 336, Processing Time 0.027 seconds

Effect of Pressurization Training with Walking on Body Composition, Respiratory Function, and Cardiovascular Response in Middle-Aged Obese Women (중년 비만여성들의 가압 트레이닝이 체성분, 호흡·순환계 기능 및 심혈관 반응에 미치는 효과)

  • Choi, Hyun-Min;Lee, Dong-Jun
    • Journal of Life Science
    • /
    • v.22 no.4
    • /
    • pp.545-551
    • /
    • 2012
  • Pressurization walk training (PWT) with blood flow occlusion has been investigated with regard to muscle hypertrophy and physical fitness function in athletes and healthy people. However, the cardiorespiratory and cardiovascular responses of obese people to PWT are unknown. Thus, we investigated the effects of PWT on body composition (Weight, FM, LBM, %fat, BMI), cardiovascular responses (HR, SV, CO, TVC), and cardiorespiratory responses ($VO_2max$, VEmax, HRmax) in middle-aged obese women. They participated in walk training with (n=15) blood flow occlusion and cross-sectional areas of the quadriceps on both legs. Five sets of 3-min walking (5.5 km/h at 5% grade) and 1-min resting were performed twice a day, 5 days/week for 3 weeks. The results showed that the LBM was significantly increased, and decreased body weight of reducing FM, %bodyfat in PWT ($p$<0.05). For the cardiovascular response, SBP and TPR were significantly decreased ($p$<0.05), and CO increased ($p$<0.05). In addition, the $VO_2max$ and VEmax were improved through PWT. Therefore, this study suggests that the presence of obesity in middle-aged women may result in body composition, cardiorespiratory, and cardiovascular responses caused by PWT.

A Study on $CO_2$ and PM10 Changes by Operation of KTX HVAC-Pressurization Equipment in Tunnel Sections (터널구간 운행시 KTX HVAC-여압장치 작동에 따른 $CO_2$와 PM10 변화연구)

  • So, Jin-Sub;Yoo, Seong-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.723-729
    • /
    • 2007
  • The Ministry of Environment established a guide line in December 2006, "Indoor Air Quality Management guidelines in Public Facilities." As the items of the guideline, $CO_2$ (Carbon dioxide) and PM10 (particulate matter) is shown to Level 1 and 2. Therefore trains and subways are included. There are a lot of tunnels by the lay of mountains on KTX (Korean Train Express) service. HVAC (Heating Ventilating and Air-conditioning)-pressurization equipment on KTX is various functioning flaps blocking outside pressure waves. At that time, the fresh air is blocked by flap operation and the air is circulated by return air. In this study, we measured the time series of $CO_2$ and PM10 concentrations in the KTX passenger cabin during the train service of Gyongbu line (Seoul-Busan) and Honan line (Yongsan-Mokpo) from July 2006. Also, analyzed the air quality by operation of KTX HVAC-pressurization equipment in tunnel passing point. As a result, PM10 concentration was totally lower than the regulation values. However, $CO_2$ was highly correlated with several tunnels, such as Oksan-Otan, Godeung-Hyudae and Gaechak-Iijik tunnel. but, the indoor air quality of KTX train have been proved satisfy the recommendation the Ministry of Environment guidelines.

Tensile Strength of Composite Laminate Repaired Using Heat-blanket and a Novel Pressurization System (히트블랑켓과 새롭게 개발된 가압장치를 이용해 수리한 복합재 적층판의 인장강도 연구)

  • Chae, Song-Su;Lee, Gwang-Eun;Ahn, Hyonsu;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • In the case of a conventional composite patch repair using a heat blanket, the adhesive is pressurized using only a vacuum bag. In this study, however, a pressurization system has been developed to apply additional air pressure on the vacuum bag. In order to verify the performance of the developed system, the composite laminates were repaired with scarf patches and then tested under tensile load to be compared with the strength of the defect-free laminate. Tensile tests were also conducted on specimens with the same configuration but bonded in an autoclave. As a result of the test, the tensile strengths of the specimens repaired using the heat blanket with vacuum only without external pressure, the specimens repaired with additional pressure by the developed system, and the specimens repaired with the same external pressure in an autoclave, showed the strength recovery ratios of 74.9, 81.0, and 78.2%, respectively. The results of the tensile test after moisture saturation and the dried fatigue test also showed that the strength recovery ratios of the specimens repaired under the external pressure of 1 atm using the developed system are slightly higher than that of specimens bonded in autoclave.

Pressurization Characteristics of Piezoelectric-Hydraulic Pump Adopting a Ball-Thin Plate Spring Type Check Valve (볼-박판 스프링 형 체크밸브가 적용된 압전유압펌프의 가압 특성)

  • Hwang, Yong-Ha;Hwang, Jai-Hyuk;Bae, Jae-Sung
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.2
    • /
    • pp.7-14
    • /
    • 2018
  • In this study, a new check valve was studied to improve the load pressure of a brake system with a small piezoelectric-hydraulic pump. During the pressurization process, the steady-state pressure at the load is affected by the ratio of the cross-sectional area of the check valve the chamber pressure and load pressure. Since the flow path cover of the check valve is made wider than the cross-sectional area of the output flow to prevent backflow, a method of reducing the area ratio is proposed for a higher load pressure by mounting an additional mass to a thin plate spring type check valve. To identify the effect of mounting an additional mass to the existing check valve on the load pressure, a simple brake system with a small piezoelectric-hydraulic pump was modeled using a commercial code AMESim. The AMESim modeling was verified by comparing the simulation results with the experimental results of the pump the existing check valve. The additional mass was added to the verified AMESim modeling and higher load pressure was able to be obtained through simulation. The 35% performance improvement in load pressure identified by carrying out pressurization test of the brake system after adopting the new check valve the small piezoelectric-hydraulic pump.

Evaluation of Prediction Methods for Containment Integrated Leakage Rate (격납건물 종합누설률 예측방법 평가)

  • Yang, Seung-Ok;Lee, Kwang-Dae;Oh, Eung-Se
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.562-564
    • /
    • 2004
  • The containment leakage rate test performed on the nuclear power plants consists of following phases : pressurizing the containment, stabilizing the atmosphere, conducting a Type A test, conducting a verification test, depressurizing the containment. It takes more than 48 hours from the pressurization to the depressurization and the prediction of the results will help to prepare the next test phase. In this paper, to predict the leakage rate, the prediction methods based on the least square method are evaluated according to the input variables and the measurement period.

  • PDF

A Study on the Shaft pressurization methods in tall buildings (고층건축물 샤프트 가압방법에 대한 연구)

  • Kim, Jin-Soo;Lee, Eui-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.89-92
    • /
    • 2012
  • 고층건물의 피난경로 제연설비는 차압형성과 방연풍량공급의 두 가지 목적을 가진다. 그러나 고층건물의 구조와 연돌효과 때문에 가압에 어느 정도의 기술적 고려가 필요하다. 피난계단실과 승강기승강로를 직접 가압하고 과압배출설비를 설치함으로써 합리적인 가압효과를 얻을 수 있다.

  • PDF

An Analysis of Operation Patterns based upon Actual Measurements of Pressurization through Open Door in Smoke Control Zone (제연구역 출입문의 차압 측정에 따른 작동패턴 해석)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.245-247
    • /
    • 2011
  • 본 연구에서는 제연구역과 옥내와의 차압 및 출입문의 폐쇄력 측정을 통해 제연구역 출입문의 작동패턴을 해석하였다. 이를 통해 제연구역 출입문의 폐쇄력 측정시 정확한 측정을 위해 출입문을 완전히 폐쇄한 상태에서 측정을 하여야 하며, 문의 크기에 비례하여 증가하는 폐쇄력을 고려한 제연설비 설계에 대한 근거를 제시하였다.

  • PDF