Evaluation of Prediction Methods for Containment Integrated Leakage Rate

격납건물 종합누설률 예측방법 평가

  • Published : 2004.11.12

Abstract

The containment leakage rate test performed on the nuclear power plants consists of following phases : pressurizing the containment, stabilizing the atmosphere, conducting a Type A test, conducting a verification test, depressurizing the containment. It takes more than 48 hours from the pressurization to the depressurization and the prediction of the results will help to prepare the next test phase. In this paper, to predict the leakage rate, the prediction methods based on the least square method are evaluated according to the input variables and the measurement period.

Keywords