• 제목/요약/키워드: Pre-heating exchanger

검색결과 8건 처리시간 0.016초

친수 표면처리 종류에 따른 공기 예열 열교환기의 응축 열전달 실험적 연구 (Experimental Study of Condensation Heat Transfer in Pre-heating Exchanger to the Type of Hydrophilic Surface Treatment)

  • 석성철;정태용;신동훈;황승식;최규홍;박재원
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.237-238
    • /
    • 2012
  • Recently, an energy-saving due to the energy utilisation efficiency enhancement is important. In order to improve the heat efficiency of the general residential boiler, We performed an experiment of condensation heat transfer to air pre-heat exchanger adhered to the condensing boiler. In this research, We analyze the heat transfer performance through the hydrophilic surface treatment(plasma, etching). The results of the research, On plasma and etching treated surface, Overall heat transfer coefficient is displayed the tendency to increase.

  • PDF

친수성 표면 처리를 통한 공기 예열 열교환기의 응축 열전달 성능 연구 (A Study on Condensation Heat Transfer in Air Pre-heating Heat Exchanger using Hydrophilic Surface)

  • 박재원;황승식;석성철;신동훈;정태용;손승길
    • 에너지공학
    • /
    • 제23권3호
    • /
    • pp.191-197
    • /
    • 2014
  • 콘덴싱 보일러에 이용되는 공기 예열 열교환기에서의 열전달을 향상시키기 위해 전열면에 플라즈마 표면처리가 응축열전달에 미치는 영향에 대하여 연구하였다. 연구 결과 표면처리를 한 친수성 평판이 원판보다 약 10%의 열전달 증진을 보여주었다. 원판과 친수처리 평판에서 측정한 응축 열전달 계수를 Shah 상관식과 비교해 본 결과 Shah 상관식이 원판에서 측정한 응축 열전달 계수를 10% 오차 범위로 잘 예측하는 것으로 나타났다. 따라서, 원판을 이용한 공기예열 열교환기를 설계할 때 Shah 상관식이 이용될 수 있음을 본 연구에서 알 수 있었다.

급탕 2단열교환방식 지역난방 열사용시설의 급탕부하 분배에 관한 연구 (Distribution of Hot Tap Water Load for District Heating Substation with Hot Tap Water 2-Stage Heat Exchanger)

  • 정동화;김주완;백영진;이영수;정대헌
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.297-302
    • /
    • 2011
  • According to the standards for district heating substation established by Korea District Heating Corporation, water heating supply systems at over 150 Mcal/h capacity must employ the 2-stage heat exchanger that improves the system efficiency by reusing the heat included in the return water of district heating system already used for space heating. In this paper, the operating characteristics of the system in accordance with the load distribution of two heat exchangers for pre-heating and re-heating cold city water are investigated. The results including mass flow rate, return temperature etc. help to manage district heating system economically.

급기 예열 열교환기에서 에칭 표면 특성이 응축 열전달에 미치는 영향에 관한 연구 (A Study on the Effects of Etching Surface Characteristics on Condensation Heat Transfer in Pre-heating Exchanger)

  • 석성철;황승식;최규홍;신동훈;정태용
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.217-222
    • /
    • 2014
  • 일반 가정용 보일러의 열효율을 증진시키기 위해서 콘덴싱 보일러에 부착되는 급기 예열 열교환기의 응축 열전달에 대한 실험을 수행하였다. 본 연구에서는 스테인리스의 표면에 대하여 에칭을 이용하여 표면 거칠기를 부과하였다. 그리고 열전달 성능 평가를 위해 대향유동 열교환기를 폴리카보네이트로 제작하였고 원판과 비교 실험을 수행하였다. 그 결과 에칭 처리한 모든 시편의 총괄열전달계수는 원판에 비해 증가하는 것을 확인할 수 있었고, 에칭 시간이 60초인 시편에서 평균 15%까지 증가하였다. 그리고 AFM 장비를 이용하여 표면 특성에 대한 분석을 통하여 열전달 증진 요인에 대해 연구하였다.

스택 폐열을 이용한 연료전지 자동차용 열펌프 시스템의 성능 특성에 관한 연구 (A Study on the Performance Characteristics of a Heat Pump System using Stack Wast Heat in Fuel Cell Vehicles)

  • 전병용;고원빈;박윤철
    • 설비공학논문집
    • /
    • 제28권8호
    • /
    • pp.325-330
    • /
    • 2016
  • This study was conducted to develop a heating system for a fuel cell-driven electric vehicle. The system consists of a compressor, an expansion device and three heat exchangers. A conventional air source heat exchanger is used as primary heat exchanger of the system, and an additional water source heat exchanger is used as a pre-heater to supply heat to the upstream air of the primary heat exchanger. On the other hand, the third heat exchanger consists of a water-to-refrigerant heat exchanger. The heat source of the pre-heater and the water-refrigerant heat exchanger is the waste heat from the fuel cell's stack. In the experiment, the indoor and the outdoor air temperature were fixed, and the compressor speed, EEV opening and waste heat temperature were varied. The results indicate that the $COP_h$ of the proposed system is 3.01 when the system is operating at a 1,200 rpm compressor speed, 50% EEV opening, and $50^{\circ}C$ waste heat source temperature in air pre-heater operation. However, when the system uses a water-refrigerant heat exchanger, the $COP_h$ increases to up to 9.42 at the same compressor speed and waste heat source temperature with 75% EEV openings.

Development and Fabrication of Heating and Water Sparging Remediation System (HWSRS) for DNAPL-contaminated Groundwater Treatment

  • Lee, Ju-Won;Park, Won-Seok;Gong, Hyo-Young;Lee, Ae-Ri;Kim, Da-Eun;Baek, Seung-Chon;Lee, Jong-Yeol
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권6호
    • /
    • pp.32-37
    • /
    • 2013
  • The scope of this study was to develop, design, and build an ex-situ remediation system of using the heating and water sparging treatment for the highly volatile DNAPL (Dense Non-Aqueous Phase Liquid) contaminated groundwater, and to conduct pilot testing at the site contaminated with DNAPL. The TCE (Trichloroethylene) removal was at the highest rate of 94.6% with the water sparging at $70^{\circ}C$ in the lab-scale test. The pilot-scale remediation system was developed, designed, and fabricated based on the results of the lab-scale test conducted. During the pilot-scale testing, DNAPL-contaminated groundwater was detained at heat exchanger for the certain period of time for pre-heating through the heat exchanger using the thermal energy supplied from the heater. The heating system supplies thermal energy to the preheated DNAPL-contaminated groundwater directly and its highly volatile TCE, $CCl_4$ (Carbontetrachloride), Chloroform are vaporized, and its vaporized and treated water is return edback to the heat exchanger. In the pilot testing the optimum condition of the HWSRS was when the water temperature at the $40^{\circ}C$ and operated with water sparging concurrently, and its TCE removal rate was 90%. The efficiency of the optimized HWSRS has been confirmed through the long-term performance evaluation process.

기울어진 덕트 내 헬리컬 코일의 자연대류 열전달 (Natural Convection Heat Transfer of an Inclined Helical Coil in a Duct)

  • 박주현;정범진
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.13-20
    • /
    • 2014
  • 헬리컬 코일이 덕트 내부에 있을 때, 기울기에 따른 자연대류 열전달을 실험적으로 측정하였다. 고부력 조건을 구현하기 위하여 유사성에 기초하여 열전달 실험을 대신하여 물질전달 실험을 수행하였다. RaD 수 $4.55{\times}10^6$에서, 턴(Turn) 수를 1~10, P/D를 1.3~5, 헬리컬 코일의 기울기를 $0^{\circ}{\sim}90^{\circ}$까지 변화시켰다. 헬리컬 코일의 턴 수가 1일 때, 측정된 $Nu_D$ 수는 McAdams의 수평관 자연대류 열전달 상관식과 거의 일치하였다. 기울어진 덕트 내 헬리컬 코일의 자연대류 열전달은 피치, 턴 수, 덕트 높이에 따라 복합적으로 변화하였고 이는 속도 효과, 굴뚝 효과, 예열 효과로 분석되었다. 본 연구의 결과는 Compact heat exchanger에서의 자연대류 열전달에 대한 현상학적 분석에 기여한다.

개량형 열회수 시스템의 열교환 성능 (Heat Exchange Performance of Improved Heat Recovery System)

  • 서원명;윤용철;권진근
    • 생물환경조절학회지
    • /
    • 제12권3호
    • /
    • pp.107-113
    • /
    • 2003
  • 본 연구에서는 온실의 온풍식 난방시스템 연통에 장착할 수 있는 폐열 회수기의 성능 개선을 목적으로 기 설계된 세 가지 열교환 장치와 기존의 장치에서 열교환 면적과 파이프의 두께 및 공기흐름 방향을 개량한 새 열교환 장치에 대해 열회수 성능을 실험적으로 비교 분석하였다. 그 결과 기존의 열 교환장치인 A형, B형 및 C형의 열회수 성능은 동일 송풍전입에서 각각 42.2%, 40.6% 및 54.4% 정도였으나 , 새로 개량된 D형은 69.2%로써 가장 현저히 높게 나타났다. 그러나 열회수용 공기의 흐름방향 변화에 따른 열회수 성능 개선효과 (A형 대비 B형)는 없는 것으로 나타나 적정 송풍기 용량이라면 직선형이 공기의 흐름방향 180${\circ}C$ 굴절시키는 헤어핀형보다 효과적인 것으로 판단된다. 결국 열회수 성능은 열회수 시스템의 열교환 면적과 열교환 파이프의 두께 및 풍속에 크게 좌우되는 것으로 나타났다. 따라서, 열교환 파이프의 내구성 등 을 고려하여 기능한 한 범위 내에서 열 교환면적을 증대시키거나 열교환 파이프의 두께를 앓게 하고 풍속을 증대시키는 것이 열회수 성능 개선효과와 직결됨을 알 수 있었다. 그리고 송풍기 용량이 필요이상으로 큰 경우, 소비전력이 많게 되는 등의 문제가 있기 때문에 적정용량 및 제품의 안정성을 고려하여 선택해야 할 것으로 판단되었다.