Abstract
This study was carried out to improve the performance of pre-developed heat recovery devices attached to exhaust-gas flue connected to combustion chamber of greenhouse heating system. Four different units were compared in the aspect of heat recovery performance; A-, B-, and C-types are exactly the same with the old ones reported in previous studies. D-type newly developed in this experiment is mainly different with the old ones in its heat exchange area and tube thickness. But airflow direction(U-turn) and pipe arrangement are similar with previous three types. The results are summarized as follows; 1. System performances in the aspect of heat recovery efficiency were estimated as 42.2% for A-type, 40.6% for B-type, 54.4% for C-type, and 69.2% for D-type. 2. There was not significant improvement of heat recovering efficiency between two different airflow directions inside the heat exchange system. But considering current technical conditions, straight air flow pattern has more advantage than hair-pin How pattern (U-turn f1ow). 3. The main factors influencing on heat recovery efficiency were presumably verified to be the total area of heat exchange surface, the thickness of ail-flow pipes, and the convective heat transfer coefficient influenced by airflow velocity under the conditions of allowable pipe durability and safety. 4. Desirable blower capacity for each type of heat recovery units were significantly different to each other. Therefore, the optimum airflow capacity should be determined by considering in economic aspect of electricity required together with the optimum heat recovery performance of given heat recovery systems.
Keywords
heat recovering device; heat exchanger; greenhouse; energy conservation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kim Y.J., G.J, Lee, J.W. Shin, Y.S, Yu and J.T. Jang. 1999, Underground hot heating system development using exhaust gas heat in the hot air heater, J. Bio-Env. Con. 8(2):100-103 (in Korean)
2 Korea Society for Agricultural Machinery, 2001, Agricultural machinery yearbook 2001-2002, p. 114 (in Korean)
3 Suh, W.M., Y.C. Yoon and J.G. Kang 2002, Heat exchanging performance as affected by arrangement of heat exchanging pipe, J. Bio.-Env. Con. 11(3):101-107 (in Korean)
4 Yoon, Y.C., W.M. Suh and J.S. Kim. 2000, Performance analysis of heat recovering device attached to hot-air-heater for greenhouse, J. Bio-Env. Con. 9(1):85-89 (in Korean)
5 Suh, W.M., Y.C. Yoon and J.G. Kang 2000, Analysis of heat exchanging performance of heat recovering device attached to exhaust gas duct. J. Bio-Env. Con. 9(4):212-222 (in Korean)
6 Nam, Y.L, 2001. Strategies for the increased corrpetitiveness of horticulture corps, Korean Research Society for Protected Horticulture, p. 99-112 (in Korean)