• Title/Summary/Keyword: Power-on reset

Search Result 50, Processing Time 0.032 seconds

Interleaved Forward Converter for High Input Voltage Application with Common Active-Clamp Circuit

  • Park, Ki-Bum;Kim, Chong-Eun;Moon, Gun-Woo;Youn, Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.400-402
    • /
    • 2008
  • A new interleaved forward converter, adopting series-input parallel-output structure with a common transformer reset circuit, is proposed in this paper. Series-input structure distributes the voltage stress on switches, which makes it suitable for high input voltage application. Paralleling output stage with an interleaving technique enables the circuit handle large output current and reduces filter size. In addition, since two forward converters share one active-clamp circuit for the transformer reset, its primary structure is simplified. All these features make the proposed converter promising for high input voltage applications with high efficiency and simple structure.

  • PDF

Experimental and analytical study of a new seismic isolation device under a column

  • Benshuai Liang;Guangtai Zhang;Mingyang Wang;Jinpeng Zhang;Jianhu Wang
    • Earthquakes and Structures
    • /
    • v.24 no.6
    • /
    • pp.415-428
    • /
    • 2023
  • Low-cost techniques with seismic isolation performance and excellent resilience need to be explored in the case of rural low-rise buildings because of the limited buying power of rural residents. As an inexpensive and eco-friendly isolation bearing, scrap tire pads (STPs) have the issue of poor resilience. Thus, a seismic isolation system under a column (SISC) integrated with STP needs to be designed for the seismic protection of low-rise rural buildings. The SISC, which is based on a simple exterior design, maintains excellent seismic performance, while the mechanical behavior of the internal STP provides elastic resilience. The horizontal behaviors of the SISC are studied through load tests, and its mechanical properties and the intrinsic mechanism of the reset ability are discussed. Results indicate that the average residual displacement ratio was 24.59%, and the reset capability was enhanced. Comparative experimental and finite element analysis results also show that the load-displacement relationship of the SISC was essentially consistent. The dynamic characteristics of isolated and fixed-base buildings were compared by numerical assessment of the response control effects, and the SISC was found to have great seismic isolation performance. SISC can be used as a low-cost base isolation device for rural buildings in developing countries.

A Study on Malfunction Mode of CMOS IC Under Narrow-Band High-Power Electromagnetic Wave (협대역 고출력 전자기파로 인한 CMOS IC에서의 오동작 특성 연구)

  • Park, Jin-Wook;Huh, Chang-Su;Seo, Chang-Su;Lee, Sung-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.9
    • /
    • pp.559-564
    • /
    • 2016
  • This study examined the malfunction mode of the HCMOS IC under narrow-band high-power electromagnetic wave. Magnetron is used to a narrow-band electromagnetic source. MFR (malfunction failure rate) was measured to investigate the HCMOS IC. In addition, we measured the resistance between specific pins of ICs, which are exposed and not exposed to the electromagnetic wave, respectively. As a test result of measurement, malfunction mode is shown in three steps. Flicker mode causing a flicker in LED connected to output pin of IC is dominant in more than 7.96 kV/m electric field. Self-reset mode causing a voltage drop to the input and output of IC during electromagnetic wave radiation is dominant in more than 9.1 kV/m electric field. Power-reset mode making a IC remained malfunction after electromagnetic radiation is dominant in more than 20.89 kV/m. As a measurement result of pin-to-pin resistance of IC, the differences between IC exposed to electromagnetic wave and normal IC were minor. However, the five in two hundred IC show a relatively low resistance. This is considered to be the result of the breakdown of pn junction when latch-up in CMOS occurred. Based on the results, the susceptibility of HCMOS IC can be applied to a basic database to IC protection and impact analysis of narrow-band high-power electromagnetic waves.

Development of An Expert System to Decide the Resetting Area of Protective Distance Relay in Power Transmission Systems (송전계통 보호 거리계전기 재정정 영역 판정 전문가시스템 개발)

  • 최면송;민병운;김기화;현승호;이승재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.8
    • /
    • pp.437-443
    • /
    • 2003
  • In this paper an expert system is developed to decide the resetting area of protective devices in power transmission systems. A configuration change in power transmission networks from a substation extension such as new line or bus addition need resetting of protective devices around the point of configuration changes. To find the resetting area in complex power system is very difficult, especially when the distance protective relays are considered to be reset. The proposed expert system, in this paper to find the resetting area has many rules based on the changes of fault currents and apparent factors from the power system alteration. It solves the problem to find relay resetting area using the network information in the database and the rule-base. The case study shows a result of the problem to find relay resetting area in KEPCO system when there is any configuration change.

A Study on Design of Digital Protective Relay for Transformer Using a DSP (DSP를 이용한 변압기용 디지털 보호계전기 설계에 관한 연구)

  • 서희석;권기백
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.39-46
    • /
    • 2003
  • In this papers, We studied system requirement specification, hardware design and implementation, protective algorithm and software design method to implement digital protective relay which has high trust and high function of protection as well as control and metering for power transformers. Protective relay for transformer is implemented on real time using DSP, which is the specific processor for digital signal processing, as a result, it is completed by the wide improvement of arithmetic capability of protective relay. Reliability is proved testing operating value and operating time, reset value and reset time of an relaying element using protective relay tester made in NF Corporation of Japan.

A CSMA/CA with Binary Exponential Back-off based Priority MAC Protocol in Tactical Wireless Networks (전술 무선망에서 2진 지수 백오프를 사용하는 CSMA/CA 기반 우선순위 적용 MAC 프로토콜 설계)

  • Byun, Ae-Ran;Son, Woong;Jang, Youn-Seon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.12-19
    • /
    • 2015
  • In network-centric warfare, the communication network has played a significant role in defeating an enemy. Especially, the urgent and important data should be preferentially delivered in time. Thus, we proposed a priority MAC protocol based on CSMA/CA with Binary Exponential Back-off for tactical wireless networks. This MAC protocol suggested a PCW(Prioritized Contention Window) with differentiated back-off time by priority and a RBR(Repetitive Back-off Reset) to reset the remaining back-off time. The results showed that this proposed MAC has higher performance than those of DCF(Distributed Coordination Function) in the transmission success rate and the number of control packet transmission by reducing the packet collision. Thus, it produced more effective power consumption. In comparison with DCF, this proposed protocol is more suitable in high-traffic network.

Implementation of the Negative Reset Waveform and Driving Circuit for High Speed Addressing in AC PDP (AC PDP에서 고속 어드레싱을 위한 네거티브 리셋 파형 및 구동회로의 구현)

  • Lim, Hyun-Muk;Lim, Seung-Beom;Lee, Jun-Young;Kang, Jung-Won;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.215-217
    • /
    • 2007
  • Recently, the demand for high definition TV is being increased by beginning of the digital broadcasting. The higher resolution of PDP is, the longer addressing time become, then, the sustain period for display image decreases. Because of the reason, dual-scan method which synchronously write information of an image on top and bottom of the screen is used for the high definition PDP. However, as the price competition of PDP becomes severe, we can`t avoid turning to a single-scan method which uses only a half of an expensive address IC. Accordingly, the sustain period becomes much shorter than prior method. In case of XGA level, it is impossible to display, eventually. In this paper, we are going to prove usefulness by realizing negative reset waveform and the driving circuit for high speed addressing.

  • PDF

Modeling and HSPICE analysis of the CMOS image sensor pixel with the complementary signal path (상보형 신호경로 방식의 CMOS 이미지센서 픽셀 모델링 및 HSPICE 해석)

  • Kim, Jin-Su;Jung, Jin-Woo;Kang, Myung-Hun;Noh, Ho-Sub;Kim, Jong-Min;Lee, Jae-Woon;Song, Han-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.41-52
    • /
    • 2008
  • In this paper, a circuit analysis of the complementary CMOS active pixel and readout circuit is carried out. Complementary pixel structure which is different from conventional 3TR APS structure is consist of photo diode, reset PMOS, several NMOSs and PMOSs sets for complementary signals. Photo diode is modelled with Medici device program. HSPICE was used to analyze the variation of the signal feature depending on light intensity using $0.5{\mu}M$ standard CMOS process. Simulation results show that the output signal range is from 0.8 V to 4.5 V. This signal range increased 135 % output dynamic range compared to conventional 3TR pixel in the condition of 5 V power supply.

Compensation Logics of Controller in Korean Standard Super Critical Once Through Boiler

  • Kim, Eun-Gee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.65.2-65
    • /
    • 2001
  • There are not only lots of controllers such as UMC(Unit Master Controller), BMC(Boiler Master Controller), Fuel Flow controller, Air flow controller, Feed water flow controller, S/H R/H Temperature controller and so on, but also compensation controller such as BTU compensator, Fuel/Water ratio controller and O2 Co controller to take automatic control in the super critical once through boiler. It is important to make complete automation of boiler to use the compensation controller like BTU compensator. For example, In case of some boiler condition, operator has to change combustion parameter for changing the coal, on the contrary BTU compensator can calculate set value of the fuel flow and reset the fuel flow demand by itself. This paper shows us the logic and instruction regarding compensation controller of boiler that can be operated automatically.

  • PDF

A Study of SR Relay Based on Solid State Type (솔리드 스테이트 타입의 SR 릴레이에 관한 연구)

  • Kim, Kee-Hwan;Kim, Yong-Ju;Shin, Dae-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.612-614
    • /
    • 2001
  • One of the frequently used relay in industry is SR relay The SR relay has roughly two kinds. Wenn the power is off, one can memorize the previous ?tate and the other can be set automatically to the initial setting position. Those relays are constructed mechanically, so that they have some disadvantages, such as electro magnetical and acoustic noise. Such problem can be easily solvedby using a microprocessor. In this contribution will show the opportunity, how easily the relay function with a microprocessor can be reconstructed. As an example the function of Impulse Set Reset Relay will be discussed.

  • PDF