• Title/Summary/Keyword: Power transmission mechanism

Search Result 175, Processing Time 0.034 seconds

Investigation of Moving Angle of Power Take off Mechanism on the Efficiency of Wave Energy Converter (파력발전기의 동력인출장치의 회전각도가 효율에 미치는 영향 분석)

  • Do, H.T.;Nguyen, M.T.;Phan, C.B.;Lee, S.Y.;Park, H.G.;Ahn, K.K.
    • Journal of Drive and Control
    • /
    • v.12 no.3
    • /
    • pp.25-35
    • /
    • 2015
  • The hydraulic power-take-off mechanism (HPTO) is one of the most popular methods in wave energy converters (WECs). However, the conventional HPTO with only one direction motion has a number of drawbacks that limit its power capture capability. This paper proposes an adjustable moving angle wave energy converter (AMAWEC) and investigates the effect of the moving angle on the performance of the wave energy converter to find the optimal moving angle in order to increase the power capture capability as well as energy efficiency. A mathematical model of components from a floating buoy to a hydraulic motor was modeled. A small scale WEC test rig was fabricated to verify the power capture capability and efficiency of the proposed system through experiments.

Energy Efficient Routing with Power Control in Sensor Networks (센서네트워크에서 전력 조절에 의한 에너지를 효율적으로 사용하는 라우팅)

  • 윤형욱;이태진
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.140-144
    • /
    • 2003
  • A sensor network consists of many low-cost, low-power, and multi-functional sensor nodes. One of most important issues in of sensor networks is to increase network lifetime, and there have been researches on the problem. In this paper, we propose a routing mechanism to prolong network lifetime, in which each node adjusts its transmission power to send data to its neighbors. We model the energy efficient routing with power control and present an algorithm to obtain the optimal flow solution for maximum network lifetime. Then, we derive an upper bound on the network lifetime for specific network topologies.

  • PDF

A Research on Characteristics of Semi-active Muffler Using Difference of Transmission Paths (전달경로의 차이를 이용한 차량용반능동형 머플러의 특성에 관한 연구)

  • 이종민;김경목;손동구;이장현;황요하
    • Journal of KSNVE
    • /
    • v.11 no.3
    • /
    • pp.401-409
    • /
    • 2001
  • Passive type mufflers installed on every car haute inherent problem of lowering engine power and fuel efficiency caused by backpressure which is byproduct of complex internal structure. Recent improvements like installing a calve to change exhaust gas path depending on power requirement and rpm have only marginally improved performance. Tremendous amount of recent research works on active exhaust noise control have failed to commercialize because of numerous physical and economical reasons. In this paper, a unique seal-active muffler using difference of transmission paths is presented. In this system exhaust pipe is divided into two and joined again downstream. Exhaust noise is reduced by destructive interference when two-divided noise join again with transmission paths'difference which is half of the wavelength of a main noise frequency. One divided path has a sliding mechanism to change length thereby transmission path length difference is adjusted to entwine rpm change. The proposed system has minimal backpressure and does not need a secondary sound source like a speaker so it can overcome many problems of failed active noise control methods. We have verified proposed system's superior performance by simulation and comparison experiment with passive mufflers.

  • PDF

Experimental Research on the Power Saving Effect Evaluation of a Variable Displacement Vane Pump for an Automatic Transmission (자동변속기용 가변 용량 베인 펌프의 파워 절감 효과 평가에 대한 실험적 연구)

  • Kim, Chulsoo;Bae, Chulyong;Kim, Chanjung;Kim, Kyusik;Son, Taekwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.7
    • /
    • pp.1-7
    • /
    • 2014
  • A variable displacement vane pump is possible to improve the fuel economy by varying the pump capacity with a vane mechanism according to the engine operating speed range and reducing its driving torque. In general the experimental evaluation of the vane pump for the transmission has been performed mainly not with the vehicle or dynamometer test rig but with component test rig due to the implementation and safety problems. In this paper, in order to evaluate the performance of the developed vane pump as well as the compatibility with other rotary and hydraulic components of the target transmission, the transmission dynamometer based test rig is implemented where the developed pump is built into it and then the variable pump capacity and effect of power reduction are investigated experimentally.

Development of the Inner Spherical Traction Continuously Variable Transmission (내구면 접촉식 무단변속장치 개발)

  • Lee, Hyoung-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.8
    • /
    • pp.863-869
    • /
    • 2006
  • A new CVT, the inner spherical traction CVT (ISCVT) is introduced. Transmission of the most scooters is the self-controlled variable pulley-belt type of CVT having some disadvantages in the fuel consumption and the limitation of the transmittable power due to the slippage between the belt and pulley. Unlike this, ISCVT controlled directly by driver is more efficient and the contact mechanism having the same line of contact normal of the spherical rotors of different radii on common center causes that the power density and torque capacity are remarkably improved. The prototype with the specifications of 50cc scooter is designed and tested.

Axial Stiffness Analysis of a Clutch Diaphragm Spring in Passenger Cars (승용차용 클러치 다이아프램 스프링의 축방향 강성해석)

  • Kim, J.Y.;Kim, J.G.;Yoon, H.J.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.35-40
    • /
    • 2010
  • This article deals with the numerical analysis results of stiffness of diaphragm spring used in the clutch of a manual transmission. In order to investigate the relationship of the force and displacement in a diaphragm spring, we have established a numerical model of diaphragm spring using a well-known analytic model of Belleville spring and a cantilever beam model for the finger part of diaphragm spring. Using the stress and strain relations of Belleville spring and cantilever beam, we propose the analytic equation of motion of diaphragm spring for the use of a clutch automated actuator in an automated manual transmission. The proposed analytic model represents the typical dynamic characteristics of diaphragm spring along with the release bearing travel. And it is characterized in a closed-form equation, therefore it can be used for the further study of development of actuator and control law of clutch automating mechanism.

Patrol Monitoring Plan for Transmission Towers with a Commercial Drone and its Field Tests (상용화 드론을 이용한 송전선로 점검방안 및 현장시험)

  • Kim, Seok-Tae;Park, Joon-Young;Lee, Jae-Kyung;Ham, Ji-Wan;Choi, Min-Hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.115-123
    • /
    • 2018
  • Various types of robots running on power transmission lines have been developed for the purpose of line patrol monitoring. They usually have complex mechanism to run and avoid obstacles on the power line, but nevertheless did not show satisfactory performance for going over the obstacles. Moreover, they were so heavy that they could not be easily installed on the lines. To compensate these problems, flying robots have been developed and recently, multi-copter drones with flight stability have been used in the electric power industry. The drones could be remotely controlled by human operators to monitor power distribution lines. In the case of transmission line patrol, however, transmission towers are huge and their spans are very long, and thus, it is very difficult for the pilot to control the patrol drones with the naked eye from a long distance away. This means that the risk of a drone crash onto electric power facilities always resides. In addition, there exists another danger of electromagnetic interference with the drones on autopilot waypoint tracking under ultra-high voltage environments. This paper presents a patrol monitoring plan of autopilot drones for power transmission lines and its field tests. First, the magnetic field effect on an autopilot patrol drone is investigated. Then, how to build the flight path to avoid the magnetic interference is proposed and our autopilot drone system is introduced. Finally, the effectiveness of the proposed patrol plan is confirmed through its field test results in the 154 kV, 345 kV and 765 kV transmission lines in Chungcheongnam-do.

Research on Transmission Line Design for Efficient RF Power Delivery to Plasma (전송선로를 이용한 플라즈마 전력 전달 연구)

  • Park, In Yong;Lee, Jang Jae;Kim, Si-Jun;Lee, Ba Da;Kim, Kwang Ki;Yeom, Hee Jung;You, Shin Jae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.2
    • /
    • pp.6-10
    • /
    • 2016
  • In RF plasma processing, when the plasma is generated, there is the difference of impedance between RF generator and plasma source. Its difference is normally reduced by using the matcher and the RF power is transferred efficiently from the power generator to the plasma source. The generated plasma has source impedance that it can be changed during processing by pressure, frequency, density and so on. If the range of source impedance excesses the matching range of the matcher, it cannot match all value of the impedance. In this research, we studied the elevation mechanism of the RF power delivery efficiency between RF generator to the plasma source by using the transmission line and impedance tuning of the plasma source. We focus on two plasma sources (capacitive coupled plasma (CCP), inductive coupled plasma (ICP)) which is most widely used in industry recently.

Resonant Frequency Estimation of Reradiation Interference at MF from Power Transmission Lines Based on Generalized Resonance Theory

  • Bo, Tang;Bin, Chen;Zhibin, Zhao;Zheng, Xiao;Shuang, Wang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1144-1153
    • /
    • 2015
  • The resonant mechanism of reradiation interference (RRI) over 1.7MHz from power transmission lines cannot be obtained from IEEE standards, which are based on researches of field intensity. Hence, the resonance is ignored in National Standards of protecting distance between UHV power lines and radio stations in China, which would result in an excessive redundancy of protecting distance. Therefore, based on the generalized resonance theory, we proposed the idea of applying model-based parameter estimation (MBPE) to estimate the generalized resonance frequency of electrically large scattering objects. We also deduced equation expressions of the generalized resonance frequency and its quality factor Q in a lossy open electromagnetic system, i.e. an antenna-transmission line system in this paper. Taking the frequency band studied by IEEE and the frequency band over 1.7 MHz as object, we established three models of the RRI from transmission lines, namely the simplified line model, the tower line model considering cross arms and the line-surface mixed model. With the models, we calculated the scattering field of sampling points with equal intervals using method of moments, and then inferred expressions of Padé rational function. After calculating the zero-pole points of the Padé rational function, we eventually got the estimation of the RRI’s generalized resonant frequency. Our case studies indicate that the proposed estimation method is effective for predicting the generalized resonant frequency of RRI in medium frequency (MF, 0.3~3 MHz) band over 1.7 MHz, which expands the frequency band studied by IEEE.

A Medium Access Control Mechanism for Distributed In-band Full-Duplex Wireless Networks

  • Zuo, Haiwei;Sun, Yanjing;Li, Song;Ni, Qiang;Wang, Xiaolin;Zhang, Xiaoguang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.11
    • /
    • pp.5338-5359
    • /
    • 2017
  • In-band full-duplex (IBFD) wireless communication supports symmetric dual transmission between two nodes and asymmetric dual transmission among three nodes, which allows improved throughput for distributed IBFD wireless networks. However, inter-node interference (INI) can affect desired packet reception in the downlink of three-node topology. The current Half-duplex (HD) medium access control (MAC) mechanism RTS/CTS is unable to establish an asymmetric dual link and consequently to suppress INI. In this paper, we propose a medium access control mechanism for use in distributed IBFD wireless networks, FD-DMAC (Full-Duplex Distributed MAC). In this approach, communication nodes only require single channel access to establish symmetric or asymmetric dual link, and we fully consider the two transmission modes of asymmetric dual link. Through FD-DMAC medium access, the neighbors of communication nodes can clearly know network transmission status, which will provide other opportunities of asymmetric IBFD dual communication and solve hidden node problem. Additionally, we leverage FD-DMAC to transmit received power information. This approach can assist communication nodes to adjust transmit powers and suppress INI. Finally, we give a theoretical analysis of network performance using a discrete-time Markov model. The numerical results show that FD-DMAC achieves a significant improvement over RTS/CTS in terms of throughput and delay.